Occupational radiation doses to the extremities and the eyes in interventional radiology and cardiology procedures

被引:111
|
作者
Efstathopoulos, E. P. [1 ]
Pantos, I. [1 ]
Andreou, M. [1 ]
Gkatzis, A. [1 ]
Carinou, E. [2 ]
Koukorava, C. [2 ]
Kelekis, N. L. [1 ]
Brountzos, E. [1 ]
机构
[1] Univ Athens, Dept Radiol 2, Sch Med, GR-12462 Athens, Greece
[2] GAEC, Aghia Paraskevi, Greece
关键词
SURGICAL PLACEMENT; STAFF DOSIMETRY; MEDICAL STAFF; PATIENT; EXPOSURE; CATHETERS; HANDS;
D O I
10.1259/bjr/83222759
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: The aim of this study was to determine occupational dose levels in interventional radiology and cardiology procedures. Methods: The study covered a sample of 25 procedures and monitored occupational dose for all laboratory personnel. Each individual wore eight thermoluminescent dosemeters next to the eyes, wrists, fingers and legs during each procedure. Radiation protection shields used in each procedure were recorded. Results: The highest doses per procedure were recorded for interventionists at the left wrist (average 485 mu Sv, maximum 5239 mu Sv) and left finger (average 324 mu Sv, maximum 2877 mu Sv), whereas lower doses were recorded for the legs (average 124 mu Sv, maximum 1959 mu Sv) and the eyes (average 64 mu Sv, maximum 1129 mu Sv). Doses to the assisting nurses during the intervention were considerably lower; the highest doses were recorded at the wrists (average 26 mu Sv, maximum 41 mu Sv) and legs (average 18 mu Sv, maximum 22 mu Sv), whereas doses to the eyes were minimal (average 4 mu Sv, maximum 16 mu Sv). Occupational doses normalised to kerma area product (KAP) ranged from 11.9 to 117.3 mu Sv/1000 cGy cm(2) and KAP was poorly correlated to the interventionists' extremity doses. Conclusion: Calculation of the dose burden for interventionists considering the actual number of procedures performed annually revealed that dose limits for the extremities and the lenses of the eyes were not exceeded. However, there are cases in which high doses have been recorded and this can lead to exceeding the dose limits when bad practices are followed and the radiation protection tools are not properly used.
引用
收藏
页码:70 / 77
页数:8
相关论文
共 50 条
  • [41] Occupational radiation doses to operators performing cardiac catheterization procedures
    Kim, Kwang Pyo
    Miller, Donald L.
    Balter, Stephen
    Kleinerman, Ruth A.
    Linet, Martha S.
    Kwon, Deukwoo
    Simon, Steven L.
    HEALTH PHYSICS, 2008, 94 (03): : 211 - 227
  • [42] Evaluation of Procedure Doses and Staff Attitudes in Interventional Cardiology in Terms of Radiation Safety
    Ugrak, Ugur
    Uzkar, Yusuf
    Duzen, Irfan
    Acar, Temel
    Karabey, Ercan
    Durmaz, Gulperi
    TURK KARDIYOLOJI DERNEGI ARSIVI-ARCHIVES OF THE TURKISH SOCIETY OF CARDIOLOGY, 2024, 52 (04): : 260 - 268
  • [43] DOSES TO OPERATORS DURING INTERVENTIONAL RADIOLOGY PROCEDURES: FOCUS ON EYE LENS AND EXTREMITY DOSIMETRY
    Koukorava, C.
    Carinou, E.
    Simantirakis, G.
    Vrachliotis, T. G.
    Archontakis, E.
    Tierris, C.
    Dimitriou, P.
    RADIATION PROTECTION DOSIMETRY, 2011, 144 (1-4) : 482 - 486
  • [44] OCCUPATIONAL RADIATION PROCEDURES AND DOSES AMONG NURSES IN SOUTH KOREA
    Jang, Mi Ya
    Lee, Won Jin
    Chun, Byung Chul
    Cha, Eun Shil
    RADIATION PROTECTION DOSIMETRY, 2020, 188 (04) : 493 - 502
  • [45] Radiation exposure of interventional cardiologists for different types of procedures in catheterization lab, is it more concern about extremities?
    Asgari, A.
    Parach, A. A.
    Daneshian, E.
    Nekoofar, Z.
    Bouzarjomehri, F.
    Mehrparvar, A. H.
    Mirmohammadi, S. J.
    Seyed-Hossaini, S. M.
    Dastmalchi, J.
    Emami, M.
    Andishmand, A.
    RADIOPROTECTION, 2020, 55 (03) : 187 - 194
  • [46] Eye Lens Doses Received by Radiation Workers in Interventional Medical Procedures
    Hiswara, E.
    Kartikasari, D.
    Sofyan, H.
    Nuraeni, N.
    Sandy, Kyp
    ATOM INDONESIA, 2020, 46 (03) : 135 - 140
  • [47] RADIATION DOSES TO ANAESTHETISTS DURING PROSTATIC ARTERY EMBOLIZATION INTERVENTIONAL PROCEDURES
    Garzon, W. J.
    Khoury, H. J.
    RADIATION PROTECTION DOSIMETRY, 2019, 185 (02) : 196 - 200
  • [48] Radiation Protection in Interventional Radiology/Cardiology-Is State-of-the-Art Equipment Used?
    Behr-Meenen, Christiane
    von Boetticher, Heiner
    Kersten, Jan Felix
    Nienhaus, Albert
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2021, 18 (24)
  • [49] Radiation dose to the heart in paediatric interventional cardiology
    Keiller, D. A.
    Martin, C. J.
    JOURNAL OF RADIOLOGICAL PROTECTION, 2015, 35 (02) : 257 - 264
  • [50] EYE DOSIMETRY IN INTERVENTIONAL RADIOLOGY AND CARDIOLOGY: CURRENT CHALLENGES AND PRACTICAL CONSIDERATIONS
    Ciraj-Bjelac, O.
    Rehani, M. M.
    RADIATION PROTECTION DOSIMETRY, 2014, 162 (03) : 329 - 337