Occupational radiation doses to the extremities and the eyes in interventional radiology and cardiology procedures

被引:111
|
作者
Efstathopoulos, E. P. [1 ]
Pantos, I. [1 ]
Andreou, M. [1 ]
Gkatzis, A. [1 ]
Carinou, E. [2 ]
Koukorava, C. [2 ]
Kelekis, N. L. [1 ]
Brountzos, E. [1 ]
机构
[1] Univ Athens, Dept Radiol 2, Sch Med, GR-12462 Athens, Greece
[2] GAEC, Aghia Paraskevi, Greece
关键词
SURGICAL PLACEMENT; STAFF DOSIMETRY; MEDICAL STAFF; PATIENT; EXPOSURE; CATHETERS; HANDS;
D O I
10.1259/bjr/83222759
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: The aim of this study was to determine occupational dose levels in interventional radiology and cardiology procedures. Methods: The study covered a sample of 25 procedures and monitored occupational dose for all laboratory personnel. Each individual wore eight thermoluminescent dosemeters next to the eyes, wrists, fingers and legs during each procedure. Radiation protection shields used in each procedure were recorded. Results: The highest doses per procedure were recorded for interventionists at the left wrist (average 485 mu Sv, maximum 5239 mu Sv) and left finger (average 324 mu Sv, maximum 2877 mu Sv), whereas lower doses were recorded for the legs (average 124 mu Sv, maximum 1959 mu Sv) and the eyes (average 64 mu Sv, maximum 1129 mu Sv). Doses to the assisting nurses during the intervention were considerably lower; the highest doses were recorded at the wrists (average 26 mu Sv, maximum 41 mu Sv) and legs (average 18 mu Sv, maximum 22 mu Sv), whereas doses to the eyes were minimal (average 4 mu Sv, maximum 16 mu Sv). Occupational doses normalised to kerma area product (KAP) ranged from 11.9 to 117.3 mu Sv/1000 cGy cm(2) and KAP was poorly correlated to the interventionists' extremity doses. Conclusion: Calculation of the dose burden for interventionists considering the actual number of procedures performed annually revealed that dose limits for the extremities and the lenses of the eyes were not exceeded. However, there are cases in which high doses have been recorded and this can lead to exceeding the dose limits when bad practices are followed and the radiation protection tools are not properly used.
引用
收藏
页码:70 / 77
页数:8
相关论文
共 50 条
  • [21] ASSESSMENT OF OCCUPATIONAL EXPOSURE IN THE MAIN PAEDIATRIC INTERVENTIONAL RADIOLOGY PROCEDURES
    Morcillo, Ana B.
    Huerga, Carlos
    Bayon, Jose
    Lopez, Antonio
    Corredoira, Eva
    Hernandez, Teresa
    Novo, Joan R.
    Ponce, Maria D.
    Fernandez, Lucia
    Rodriguez, Ricardo
    Garzon, Gonzalo
    Vano, Eliseo
    Guibelalde, Eduardo
    Alejo, Luis
    RADIATION PROTECTION DOSIMETRY, 2022, 198 (07) : 386 - 392
  • [22] OCCUPATIONAL DOSES FOR THE FIRST AND SECOND OPERATORS IN LEBANESE INTERVENTIONAL CARDIOLOGY SUITES
    Rizk, C.
    Farah, J.
    Fares, G.
    Vanhavere, F.
    RADIATION PROTECTION DOSIMETRY, 2018, 182 (04) : 438 - 447
  • [23] ASSESSMENT OF OCCUPATIONAL RADIATION DOSES IN DIFFERENT DIAGNOSTIC, INTERVENTIONAL AND THERAPEUTIC RADIOLOGY AND MOLECULAR IMAGING SERVICES IN OMAN
    Bouchareb, Yassine
    Al-Maimani, Naema
    Al-Maskery, Ibtisam
    Al-Zeheimi, Hilal
    Al-Rasbi, Amaal
    Al-Dhuhli, Humoud
    Al-Makhmari, Noura
    Al-Haji, Amal
    RADIATION PROTECTION DOSIMETRY, 2021, 197 (01) : 36 - 45
  • [24] CONTEMPORARY RADIATION DOSES IN INTERVENTIONAL CARDIOLOGY: A NATIONWIDE STUDY OF PATIENT DOSES IN FINLAND
    Jarvinen, Jukka
    Sierpowska, Joanna
    Siiskonen, Teemu
    Jarvinen, Hannu
    Kiviniemi, Tuomas
    Rissanen, Tuomas T.
    Matikka, Hanna
    Niskanen, Eini
    Hurme, Saija
    Larjava, Heli R. S.
    Makela, Timo J.
    Strengell, Satu
    Eskola, Markku
    Parviainen, Teuvo
    Hallinen, Elina
    Pirinen, Markku
    Kivela, Antti
    Teras, Mika
    RADIATION PROTECTION DOSIMETRY, 2019, 185 (04) : 483 - 493
  • [25] ASSESSMENT OF THE OCCUPATIONAL EXPOSURE IN REAL TIME DURING INTERVENTIONAL CARDIOLOGY PROCEDURES
    Baptista, M.
    Figueira, C.
    Teles, P.
    Cardoso, G.
    Zankl, M.
    Vaz, P.
    RADIATION PROTECTION DOSIMETRY, 2015, 165 (1-4) : 304 - 309
  • [26] Survey of the interventional cardiology procedures in Italy
    Compagnone, Gaetano
    Campanella, Francesco
    Domenichelli, Sara
    Lo Meo, Sergio
    Bonelli, Marco
    delle Canne, Stefania
    Isoardi, Paola
    Marinaro, Michele
    Ursetta, Massimo
    Curini, Roberta
    RADIATION PROTECTION DOSIMETRY, 2012, 150 (03) : 316 - 324
  • [27] Assessment of the Occupational Radiation Exposure of Anesthesia Staff in Interventional Cardiology
    Shbeer, Abdullah
    RISK MANAGEMENT AND HEALTHCARE POLICY, 2024, 17 : 1093 - 1100
  • [28] Patient radiation doses and reference levels in pediatric interventional radiology
    Geryes, Bouchra Habib
    Bak, Adeline
    Lachaux, Julie
    Ozanne, Augustin
    Boddaert, Nathalie
    Brunelle, Francis
    Naggara, Olivier
    Saliou, Guillaume
    EUROPEAN RADIOLOGY, 2017, 27 (09) : 3983 - 3990
  • [29] Effectiveness of staff radiation protection devices for interventional cardiology procedures
    Huet, Christelle
    Dabin, Jeremie
    Domienik-Andrzejewska, Joanna
    Hebre, Alexandre
    da Silva, Edilaine Honorio
    Lombardo, Pasquale
    Tamborino, Giulia
    Vanhavere, Filip
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2023, 107
  • [30] A novel robotic radiation shielding device for interventional cardiology procedures
    Laish-Farkash, Avishag
    Harari, Emanuel
    Finkelstein, Ariel
    Sheinman, Guy
    Rahkovich, Michael
    Kogan, Yonatan
    Lev, Eli Israel
    EUROINTERVENTION, 2022, 18 (03) : 262 - +