Objectives: The aim of this study was to determine occupational dose levels in interventional radiology and cardiology procedures. Methods: The study covered a sample of 25 procedures and monitored occupational dose for all laboratory personnel. Each individual wore eight thermoluminescent dosemeters next to the eyes, wrists, fingers and legs during each procedure. Radiation protection shields used in each procedure were recorded. Results: The highest doses per procedure were recorded for interventionists at the left wrist (average 485 mu Sv, maximum 5239 mu Sv) and left finger (average 324 mu Sv, maximum 2877 mu Sv), whereas lower doses were recorded for the legs (average 124 mu Sv, maximum 1959 mu Sv) and the eyes (average 64 mu Sv, maximum 1129 mu Sv). Doses to the assisting nurses during the intervention were considerably lower; the highest doses were recorded at the wrists (average 26 mu Sv, maximum 41 mu Sv) and legs (average 18 mu Sv, maximum 22 mu Sv), whereas doses to the eyes were minimal (average 4 mu Sv, maximum 16 mu Sv). Occupational doses normalised to kerma area product (KAP) ranged from 11.9 to 117.3 mu Sv/1000 cGy cm(2) and KAP was poorly correlated to the interventionists' extremity doses. Conclusion: Calculation of the dose burden for interventionists considering the actual number of procedures performed annually revealed that dose limits for the extremities and the lenses of the eyes were not exceeded. However, there are cases in which high doses have been recorded and this can lead to exceeding the dose limits when bad practices are followed and the radiation protection tools are not properly used.
引用
收藏
页码:70 / 77
页数:8
相关论文
共 50 条
  • [1] Assessment of occupational radiation doses to eye lens during interventional radiology procedures
    Ali, Amir
    Al-Nuaimi, Meshari
    Khan, Banaras
    Burki, Shamsullah
    Nishtar, Tahira
    Yaseen, Muhammad
    Shah, Syed Sher Azam
    Irfan, Muhammad
    RADIATION PHYSICS AND CHEMISTRY, 2024, 225
  • [2] Recommendations for occupational radiation protection in interventional cardiology
    Duran, Ariel
    Hian, Sim Kui
    Miller, Donald L.
    Le Heron, John
    Padovani, Renato
    Vano, Eliseo
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2013, 82 (01) : 29 - 42
  • [3] Patient radiation doses in paediatric interventional cardiology procedures: a review
    Harbron, R. W.
    Dreuil, S.
    Bernier, M-O
    Pearce, M. S.
    Thierry-Chef, I.
    Chapple, C-L
    Baysson, H.
    JOURNAL OF RADIOLOGICAL PROTECTION, 2016, 36 (04) : R131 - R144
  • [4] Managing occupational doses with smartphones in interventional radiology
    Sanchez, Roberto M.
    Fernandez, Daniel
    Vano, Eliseo
    Fernandez, Jose M.
    MEDICAL PHYSICS, 2021, 48 (10) : 5830 - 5836
  • [5] COMPARING MEASURED AND CALCULATED DOSES IN INTERVENTIONAL CARDIOLOGY PROCEDURES
    Oliveira da Silva, M. W.
    Canevaro, L. V.
    Hunt, J.
    Rodrigues, B. B. D.
    RADIATION PROTECTION DOSIMETRY, 2017, 176 (04) : 439 - 443
  • [6] Occupational doses to the eye lens in pediatric and adult noncardiac interventional radiology procedures
    Morcillo, Ana Belen
    Alejo, Luis
    Huerga, Carlos
    Bayon, Jose
    Marin, Alberto
    Corredoira, Eva
    Novo, Joan Ricardo
    Hernandez, Teresa
    Ponce, Maria Dolores
    Garzon, Gonzalo
    Vano, Eliseo
    Guibelalde, Eduardo
    MEDICAL PHYSICS, 2021, 48 (04) : 1956 - 1966
  • [7] Occupational Dose in Interventional Radiology Procedures
    Chida, Koichi
    Kaga, Yuji
    Haga, Yoshihiro
    Kataoka, Nozomi
    Kumasaka, Eriko
    Meguro, Taiichiro
    Zuguchi, Masayuki
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 200 (01) : 138 - 141
  • [8] Measurement of occupational doses of ionising radiation to the lens of the eyes of interventional radiologists
    Higgins, Anthony
    JOURNAL OF RADIOLOGICAL PROTECTION, 2016, 36 (01) : 74 - 92
  • [9] Informed Consent for Radiation in Interventional Radiology Procedures
    Zener, Rebecca
    Johnson, Peter
    Wiseman, Daniele
    Pandey, Sachin
    Mujoomdar, Amol
    CANADIAN ASSOCIATION OF RADIOLOGISTS JOURNAL-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 2018, 69 (01): : 30 - 37
  • [10] Occupational Radiation Protection in Interventional Radiology: A Joint Guideline of the Cardiovascular and Interventional Radiology Society of Europe and the Society of Interventional Radiology
    Miller, Donald L.
    Vano, Eliseo
    Bartal, Gabriel
    Balter, Stephen
    Dixon, Robert
    Padovani, Renato
    Schueler, Beth
    Cardella, John F.
    de Baere, Thierry
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2010, 33 (02) : 230 - 239