Quantitative second-harmonic generation microscopy in collagen

被引:135
|
作者
Stoller, P
Celliers, PM
Reiser, KM
Rubenchik, AM
机构
[1] Lawrence Livermore Natl Lab, Livermore, CA 94551 USA
[2] Univ Calif Davis, Dept Neurol Surg, Sch Med, Sacramento, CA 95817 USA
[3] Lawrence Livermore Natl Lab, NIF Program, Livermore, CA 94551 USA
关键词
D O I
10.1364/AO.42.005209
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The second-harmonic signal in collagen, even in highly organized samples such as rat tail tendon fascicles, varies significantly with position. Previous studies suggest that this variability may be due to the parallel and antiparallel orientation of neighboring collagen fibrils. We applied high-resolution second-harmonic generation microscopy to confirm this hypothesis. Studies in which the focal spot diameter was varied from similar to1 to similar to6 mum strongly suggest that regions in which collagen fibrils have the same orientation in rat tail tendon are likely to be less than similar to1 mum in diameter. These measurements required accurate determination of the focal spot size achieved by use of different microscope objectives; we developed a technique that uses second-harmonic generation in a quartz reference to measure the focal spot diameter directly. We also used the quartz reference to determine a lower limit (d(XXX) > 0.4 pm/V) for the magnitude of the second-order nonlinear susceptibility in collagen. (C) 2003 Optical Society of America.
引用
收藏
页码:5209 / 5219
页数:11
相关论文
共 50 条
  • [31] Second-harmonic generation in second-harmonic fiber Bragg gratings
    Steel, MJ
    deSterke, CM
    APPLIED OPTICS, 1996, 35 (18) : 3211 - 3222
  • [32] Second-harmonic microscopy - A quantitative probe for molecular surface order
    Florsheimer, M
    Bosch, M
    Brillert, C
    Wierschem, M
    Fuchs, H
    ADVANCED MATERIALS, 1997, 9 (13) : 1061 - &
  • [33] Application of quantitative second-harmonic generation microscopy to posterior cruciate ligament for crimp analysis studies
    Lee, Woowon
    Rahman, Hafizur
    Kersh, Mariana E.
    Toussaint, Kimani C., Jr.
    JOURNAL OF BIOMEDICAL OPTICS, 2017, 22 (04)
  • [34] Second-harmonic generation scanning microscopy on domains in Al surfaces
    Pedersen, K
    Bozhevolnyi, SI
    PHYSICA STATUS SOLIDI A-APPLIED RESEARCH, 1999, 175 (01): : 201 - 206
  • [35] Analyzing chromosome condensation in yeast by second-harmonic generation microscopy
    Yamin, Katreena
    Assa, Michael
    Matityahu, Avi
    Onn, Itay
    CURRENT GENETICS, 2020, 66 (02) : 437 - 443
  • [36] Analyzing chromosome condensation in yeast by second-harmonic generation microscopy
    Katreena Yamin
    Michael Assa
    Avi Matityahu
    Itay Onn
    Current Genetics, 2020, 66 : 437 - 443
  • [37] Mechanisms of membrane potential sensing with second-harmonic generation microscopy
    Pons, T
    Moreaux, L
    Mongin, O
    Blanchard-Desce, M
    Mertz, J
    JOURNAL OF BIOMEDICAL OPTICS, 2003, 8 (03) : 428 - 431
  • [38] Second-harmonic generation microscopy analysis reveals proteoglycan decorin is necessary for proper collagen organization in prostate
    Campbell, Kirby R.
    Chaudhary, Rajeev
    Montano, Monica
    Iozzo, Renato, V
    Bushman, Wade A.
    Campagnola, Paul J.
    JOURNAL OF BIOMEDICAL OPTICS, 2019, 24 (06)
  • [39] Electric-field-induced second-harmonic generation microscopy
    Canterbury, Jesse D.
    Wilson, Philip T.
    Downer, Michael C.
    Pacific Rim Conference on Lasers and Electro-Optics, CLEO - Technical Digest, 2000, : 219 - 220
  • [40] Optical recording of action potentials with second-harmonic generation microscopy
    Dombeck, DA
    Blanchard-Desce, M
    Webb, WW
    JOURNAL OF NEUROSCIENCE, 2004, 24 (04): : 999 - 1003