Cardiac transplantation after mechanical circulatory support: A Canadian perspective

被引:21
作者
Masters, RG
Hendry, PJ
Davies, RA
Smith, S
Struthers, C
Walley, VM
Veinot, JP
Mussivand, TV
Keon, WJ
机构
[1] UNIV OTTAWA,OTTAWA CIVIC HOSP,INST HEART,DIV CARDIOL,OTTAWA,ON K1Y 4E9,CANADA
[2] UNIV OTTAWA,OTTAWA CIVIC HOSP,INST HEART,DIV PATHOL,OTTAWA,ON K1Y 4E9,CANADA
关键词
D O I
10.1016/0003-4975(96)00138-5
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. To assess the relative efficacy of cardiac transplantation after mechanical circulatory support with a variety of support systems, we analyzed our consecutive series of patients who had and did not have mechanical support before transplantation. Methods. A review of 209 patients undergoing cardiac transplantation from 1984 to May 1995 was performed. Group consisted of 110 patients who were maintained on oral medications while awaiting transplantation, and group 2 consisted of 60 patients who required intravenous inotropic support. Group 3 included 39 patients who had transplantation after mechanical circulatory support for cardiogenic shock. The indication for device implantation was acute onset of cardiogenic shock in 38 patients and deterioration while awaiting transplantation in 1 patient. The support systems were an intraaortic balloon pump in 13 (subgroup 3A), a ventricular assist device in 7 (subgroup 3B), and a total artificial heart in 19 patients (subgroup 3C). Results. After transplantation, infection was more common in group 3 (56%) than in group 1 (28%) or group 2 (32%) (p = 0.005). Survival to discharge was lower for group 3 (71.7%) than for group 1 (90.9%) or 2 (88.3%) (p = 0.009). For mechanically supported patients, survival to discharge was 84.6% in subgroup 3A, 71.4% in subgroup 3B, and 63.1% in subgroup 3C (p = not significant). Conclusions. Transplantation after mechanical support offers acceptable results in this group of patients for whom the only alternative is certain death. Patient selection and perioperative management remain the challenge to improving these results.
引用
收藏
页码:1734 / 1739
页数:6
相关论文
共 13 条
[1]  
Copeland JG, 1996, J HEART LUNG TRANSPL, V15, P94
[2]  
FARRAR DJ, 1994, J HEART LUNG TRANSPL, V13, P93
[3]   UNIVENTRICULAR AND BIVENTRICULAR THORATEC VAD SUPPORT AS A BRIDGE TO TRANSPLANTATION [J].
FARRAR, DJ ;
HILL, JD .
ANNALS OF THORACIC SURGERY, 1993, 55 (01) :276-282
[4]   MULTICENTER CLINICAL-EVALUATION OF THE HEARTMATE 1000-IP LEFT-VENTRICULAR ASSIST DEVICE [J].
FRAZIER, OH ;
ROSE, EA ;
MACMANUS, Q ;
BURTON, NA ;
LEFRAK, EA ;
POIRIER, VL ;
DASSE, KA .
ANNALS OF THORACIC SURGERY, 1992, 53 (06) :1080-1090
[5]   ACTUARIAL ANALYSIS OF SURGICAL RESULTS - RATIONALE AND METHOD [J].
GRUNKEMEIER, GL ;
STARR, A .
ANNALS OF THORACIC SURGERY, 1977, 24 (05) :404-408
[6]  
HENDRY PJ, 1989, J THORAC CARDIOV SUR, V98, P517
[7]   DETERMINANTS OF HOSPITAL SURVIVAL AFTER CARDIAC TRANSPLANTATION [J].
IBRAHIM, M ;
MASTERS, RG ;
HENDRY, PJ ;
DAVIES, RA ;
SMITH, S ;
STRUTHERS, C ;
WALLEY, VM ;
KEON, WJ .
ANNALS OF THORACIC SURGERY, 1995, 59 (03) :604-608
[8]  
JOHNSON KE, 1992, J HEART LUNG TRANSPL, V11, P103
[9]  
KAYE MP, 1993, J HEART LUNG TRANSPL, V12, P541
[10]   EVOLVING EXPERIENCE WITH MECHANICAL CIRCULATORY SUPPORT [J].
KORMOS, RL ;
BOROVETZ, HS ;
ARMITAGE, JM ;
HARDESTY, RL ;
MARRONE, GC ;
GRIFFITH, BP .
ANNALS OF SURGERY, 1991, 214 (04) :471-477