Combined EEG/MEG Can Outperform Single Modality EEG or MEG Source Reconstruction in Presurgical Epilepsy Diagnosis

被引:64
|
作者
Aydin, Uemit [1 ,2 ]
Vorwerk, Johannes [1 ]
Duempelmann, Matthias [3 ]
Kuepper, Philipp [1 ,4 ]
Kugel, Harald [3 ,5 ]
Heers, Marcel [6 ]
Wellmer, Joerg [6 ]
Kellinghaus, Christoph [4 ]
Haueisen, Jens [2 ]
Rampp, Stefan [6 ,7 ]
Stefan, Hermann [7 ]
Wolters, Carsten H. [1 ]
机构
[1] Univ Munster, Inst Biomagnetism & Biosignalanal, D-48149 Munster, Germany
[2] Tech Univ Ilmenau, Inst Biomed Engn & Informat, Ilmenau, Germany
[3] Univ Freiburg Klinikum, Epilepsy Ctr, Freiburg, Germany
[4] Klin Osnabruck, Dept Neurol, Osnabruck, Germany
[5] Univ Munster, Dept Clin Radiol, D-48149 Munster, Germany
[6] Univ Knappschaftskrankenhaus Bochum, Ruhr Epileptol Dept Neurol, Bochum, Germany
[7] Univ Erlangen Nurnberg, Dept Neurol, Epilepsy Ctr, Erlangen, Germany
来源
PLOS ONE | 2015年 / 10卷 / 03期
关键词
TEMPORAL-LOBE EPILEPSY; SOURCE LOCALIZATION; HEAD MODEL; EPILEPTIFORM ACTIVITY; INTERICTAL SPIKES; HUMAN SKULL; ELECTRICAL-CONDUCTIVITY; EPILEPTOGENIC ZONE; VOLUME CONDUCTOR; INVERSE PROBLEM;
D O I
10.1371/journal.pone.0118753
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
We investigated two important means for improving source reconstruction in presurgical epilepsy diagnosis. The first investigation is about the optimal choice of the number of epileptic spikes in averaging to (1) sufficiently reduce the noise bias for an accurate determination of the center of gravity of the epileptic activity and (2) still get an estimation of the extent of the irritative zone. The second study focuses on the differences in single modality EEG (80-electrodes) or MEG (275-gradiometers) and especially on the benefits of combined EEG/MEG (EMEG) source analysis. Both investigations were validated with simultaneous stereo-EEG (sEEG) (167-contacts) and low-density EEG (ldEEG) (21-electrodes). To account for the different sensitivity profiles of EEG and MEG, we constructed a six-compartment finite element head model with anisotropic white matter conductivity, and calibrated the skull conductivity via somatosensory evoked responses. Our results show that, unlike single modality EEG or MEG, combined EMEG uses the complementary information of both modalities and thereby allows accurate source reconstructions also at early instants in time (epileptic spike onset), i.e., time points with low SNR, which are not yet subject to propagation and thus supposed to be closer to the origin of the epileptic activity. EMEG is furthermore able to reveal the propagation pathway at later time points in agreement with sEEG, while EEG or MEG alone reconstructed only parts of it. Subaveraging provides important and accurate information about both the center of gravity and the extent of the epileptogenic tissue that neither single nor grand-averaged spike localizations can supply.
引用
收藏
页数:29
相关论文
共 50 条
  • [21] ITERATIVE MUSIC FOR HIGHLY CORRELATED EEG/MEG SOURCE LOCALIZATION
    Cui, Yuan
    Gao, Shan
    Zhang, Junpeng
    BIOMEDICAL ENGINEERING-APPLICATIONS BASIS COMMUNICATIONS, 2013, 25 (02):
  • [22] Influence of the head model on EEG and MEG source connectivity analyses
    Cho, Jae-Hyun
    Vorwerk, Johannes
    Wolters, Carsten H.
    Knoesche, Thomas R.
    NEUROIMAGE, 2015, 110 : 60 - 77
  • [23] Recursive MUSIC: A framework for EEG and MEG source localization
    Mosher, JC
    Leahy, RM
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1998, 45 (11) : 1342 - 1354
  • [24] Ictal EEG Source Imaging for Presurgical Evaluation of Refractory Focal Epilepsy
    Habib, Mohammad Ashfak
    Ibrahim, Fatimah
    Mohktar, Mas S.
    Kamaruzzaman, Shahrul Bahyah
    Rahmat, Kartini
    Lim, Kheng Seang
    WORLD NEUROSURGERY, 2016, 88 : 576 - 585
  • [25] Regularized FOCUSS algorithm for EEG/MEG source imaging
    Han, J
    Park, KS
    PROCEEDINGS OF THE 26TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2004, 26 : 122 - 124
  • [26] EEG Source Imaging in Partial Epilepsy in Comparison with Presurgical Evaluation and Magnetoencephalography
    Park, Chae Jung
    Seo, Ji Hye
    Kim, Daeyoung
    Abibullaev, Berdakh
    Kwon, Hyukchan
    Lee, Yong-Ho
    Kim, Min-Young
    An, Kyung-min
    Kim, Kiwoong
    Kim, Jeong Sik
    Joo, Eun Yeon
    Hong, Seung Bong
    JOURNAL OF CLINICAL NEUROLOGY, 2015, 11 (04): : 319 - 330
  • [27] Source analysis of EEG oscillations using high-resolution EEG and MEG
    Srinivasan, Ramesh
    Winter, William R.
    Nunez, Paul L.
    EVENT-RELATED DYNAMICS OF BRAIN OSCILLATIONS, 2006, 159 : 29 - 42
  • [28] MEG-EEG Information Fusion and Electromagnetic Source Imaging: From Theory to Clinical Application in Epilepsy
    Chowdhury, Rasheda Arman
    Zerouali, Younes
    Hedrich, Tanguy
    Heers, Marcel
    Kobayashi, Eliane
    Lina, Jean-Marc
    Grova, Christophe
    BRAIN TOPOGRAPHY, 2015, 28 (06) : 785 - 812
  • [29] Simultaneous MEG and EEG to detect ripples in people with focal epilepsy
    van Klink, Nicole
    Mooij, Anne
    Huiskamp, Geertjan
    Ferrier, Cyrille
    Braun, Kees
    Hillebrand, Arjan
    Zijlmans, Maeike
    CLINICAL NEUROPHYSIOLOGY, 2019, 130 (07) : 1175 - 1183
  • [30] A Parametric Empirical Bayesian Framework for fMRI-Constrained MEG/EEG Source Reconstruction
    Henson, Richard N.
    Flandin, Guillaume
    Friston, Karl J.
    Mattout, Jeremie
    HUMAN BRAIN MAPPING, 2010, 31 (10) : 1512 - 1531