Combined EEG/MEG Can Outperform Single Modality EEG or MEG Source Reconstruction in Presurgical Epilepsy Diagnosis

被引:64
|
作者
Aydin, Uemit [1 ,2 ]
Vorwerk, Johannes [1 ]
Duempelmann, Matthias [3 ]
Kuepper, Philipp [1 ,4 ]
Kugel, Harald [3 ,5 ]
Heers, Marcel [6 ]
Wellmer, Joerg [6 ]
Kellinghaus, Christoph [4 ]
Haueisen, Jens [2 ]
Rampp, Stefan [6 ,7 ]
Stefan, Hermann [7 ]
Wolters, Carsten H. [1 ]
机构
[1] Univ Munster, Inst Biomagnetism & Biosignalanal, D-48149 Munster, Germany
[2] Tech Univ Ilmenau, Inst Biomed Engn & Informat, Ilmenau, Germany
[3] Univ Freiburg Klinikum, Epilepsy Ctr, Freiburg, Germany
[4] Klin Osnabruck, Dept Neurol, Osnabruck, Germany
[5] Univ Munster, Dept Clin Radiol, D-48149 Munster, Germany
[6] Univ Knappschaftskrankenhaus Bochum, Ruhr Epileptol Dept Neurol, Bochum, Germany
[7] Univ Erlangen Nurnberg, Dept Neurol, Epilepsy Ctr, Erlangen, Germany
来源
PLOS ONE | 2015年 / 10卷 / 03期
关键词
TEMPORAL-LOBE EPILEPSY; SOURCE LOCALIZATION; HEAD MODEL; EPILEPTIFORM ACTIVITY; INTERICTAL SPIKES; HUMAN SKULL; ELECTRICAL-CONDUCTIVITY; EPILEPTOGENIC ZONE; VOLUME CONDUCTOR; INVERSE PROBLEM;
D O I
10.1371/journal.pone.0118753
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
We investigated two important means for improving source reconstruction in presurgical epilepsy diagnosis. The first investigation is about the optimal choice of the number of epileptic spikes in averaging to (1) sufficiently reduce the noise bias for an accurate determination of the center of gravity of the epileptic activity and (2) still get an estimation of the extent of the irritative zone. The second study focuses on the differences in single modality EEG (80-electrodes) or MEG (275-gradiometers) and especially on the benefits of combined EEG/MEG (EMEG) source analysis. Both investigations were validated with simultaneous stereo-EEG (sEEG) (167-contacts) and low-density EEG (ldEEG) (21-electrodes). To account for the different sensitivity profiles of EEG and MEG, we constructed a six-compartment finite element head model with anisotropic white matter conductivity, and calibrated the skull conductivity via somatosensory evoked responses. Our results show that, unlike single modality EEG or MEG, combined EMEG uses the complementary information of both modalities and thereby allows accurate source reconstructions also at early instants in time (epileptic spike onset), i.e., time points with low SNR, which are not yet subject to propagation and thus supposed to be closer to the origin of the epileptic activity. EMEG is furthermore able to reveal the propagation pathway at later time points in agreement with sEEG, while EEG or MEG alone reconstructed only parts of it. Subaveraging provides important and accurate information about both the center of gravity and the extent of the epileptogenic tissue that neither single nor grand-averaged spike localizations can supply.
引用
收藏
页数:29
相关论文
共 50 条
  • [1] MEG and EEG in epilepsy
    Barkley, GL
    Baumgartner, C
    JOURNAL OF CLINICAL NEUROPHYSIOLOGY, 2003, 20 (03) : 163 - 178
  • [2] EEG/MEG source reconstruction in non-lesional epilepsy
    Heide, Ev-Christin
    Rampp, Stefan
    van de Velden, Daniel
    Seeck, Margitta
    Focke, Niels K.
    CLINICAL EPILEPTOLOGY, 2023, 36 (02) : 111 - 116
  • [3] Presurgical Localization of Language in MEG and EEG
    Pataraia, Ekaterina
    Trimmel, Karin
    KLINISCHE NEUROPHYSIOLOGIE, 2018, 49 (01) : 41 - 47
  • [4] Reproducibility of EEG-MEG fusion source analysis of interictal spikes: Relevance in presurgical evaluation of epilepsy
    Chowdhury, Rasheda Arman
    Pellegrino, Giovanni
    Aydin, Umit
    Lina, Jean-Marc
    Dubeau, Francois
    Kobayashi, Eliane
    Grova, Christophe
    HUMAN BRAIN MAPPING, 2018, 39 (02) : 880 - 901
  • [5] Validating EEG, MEG and Combined MEG and EEG Beamforming for an Estimation of the Epileptogenic Zone in Focal Cortical Dysplasia
    Neugebauer, Frank
    Antonakakis, Marios
    Unnwongse, Kanjana
    Parpaley, Yaroslav
    Wellmer, Joerg
    Rampp, Stefan
    Wolters, Carsten H.
    BRAIN SCIENCES, 2022, 12 (01)
  • [6] Combining sparsity and rotational invariance in EEG/MEG source reconstruction
    Haufe, Stefan
    Nikulin, Vadim V.
    Ziehe, Andreas
    Mueller, Klaus-Robert
    Nolte, Guido
    NEUROIMAGE, 2008, 42 (02) : 726 - 738
  • [7] SINGLE MEG/EEG SOURCE RECONSTRUCTION WITH MULTIPLE SPARSE PRIORS AND VARIABLE PATCHES
    Lopez, Jose D.
    Barnes, Gareth R.
    Espinosa, Jairo J.
    DYNA-COLOMBIA, 2012, 79 (174): : 136 - 144
  • [8] Network Perspectives on Epilepsy Using EEG/MEG Source Connectivity
    van Mierlo, Pieter
    Holler, Yvonne
    Focke, Niels K.
    Vulliemoz, Serge
    FRONTIERS IN NEUROLOGY, 2019, 10
  • [9] Simultaneous EEG and MEG source reconstruction in sparse electromagnetic source imaging
    Ding, Lei
    Yuan, Han
    HUMAN BRAIN MAPPING, 2013, 34 (04) : 775 - 795
  • [10] Source Reconstruction Accuracy of MEG and EEG Bayesian Inversion Approaches
    Belardinelli, Paolo
    Ortiz, Erick
    Barnes, Gareth
    Noppeney, Uta
    Preissl, Hubert
    PLOS ONE, 2012, 7 (12):