Modeling ultrasonic wave propagation in a dental implant - Bone system

被引:8
作者
Dorogoy, A. [1 ]
Haiat, G. [2 ]
Shemtov-Yona, K. [1 ]
Rittel, D. [1 ]
机构
[1] Technion, Fac Mech Engn, IL-32000 Haifa, Israel
[2] CNRS, UMR CNRS 8202, Lab Modelisat & Simulat Multiechelle, F-94010 Creteil, France
基金
欧洲研究理事会;
关键词
Dental implants; Ultrasound; Bone-implant interface; Finite element; Waves; Stability; BIOMECHANICAL STABILITY; NUMERICAL-SIMULATION; OSSEOINTEGRATION; TIME;
D O I
10.1016/j.jmbbm.2019.103547
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The evolution of the bone-implant interface reflects the implant osseointegration and bond strength, thereby determining the overall implant stability in the jawbone. Quantitative ultrasound represents a promising alternative technique to characterize the interfacial integrity, precisely due to the fact that those waves propagate essentially along the bone-implant interface, and are therefore influenced by its state. This study reports a numerical investigation of ultrasonic wave propagation for a commercial implant-jawbone system in which the thickness and mechanical properties of the interfacial layer (corresponding to the interphase) are systematically varied through the application of a rule of mixtures, in order to mimic the evolution from a dominantly soft tissue - like medium up to a fully healed bone. A simple figure of merit is devised in terms of an RMS-like (root mean square) factor based on the implant displacements, that evolves continuously and significantly with the bone "healing" process, thereby providing unequivocal information on the nature of the investigated bone-implant interface. The results show that the wave propagation pattern is primarily dictated by the impedance mismatch rather than by the interface thickness. This study validates the concept of quantitative ultrasonic testing as a sensitive alternative to the widespread resonant frequency analysis, thereby opening the way for future sensitivity analyses that will address more refined bone-implant interface pathologies such as those observed in the clinical realm.
引用
收藏
页数:7
相关论文
共 26 条
[1]   Hard tissue implant interface [J].
Albrektsson, T. .
AUSTRALIAN DENTAL JOURNAL, 2008, 53 :S34-S38
[2]  
American Society for Testing and M. American Society for Testing and Materials, 2013, STAND SPEC WROUGHT T
[3]   Validity and clinical significance of biomechanical testing of implant/bone interface [J].
Aparicio, Carlos ;
Lang, Niklaus R. ;
Rangert, Bo .
CLINICAL ORAL IMPLANTS RESEARCH, 2006, 17 :2-7
[4]   The prognostic accuracy of resonance frequency analysis in predicting failure risk of immediately restored implants [J].
Atieh, Momen A. ;
Alsabeeha, Nabeel H. M. ;
Payne, Alan G. T. ;
de Silva, Rohana K. ;
Schwass, Donald S. ;
Duncan, Warwick J. .
CLINICAL ORAL IMPLANTS RESEARCH, 2014, 25 (01) :29-35
[5]  
Atieh MA, 2012, INT J PROSTHODONT, V25, P326
[6]   Proposal for an ultrasonic tool to monitor the osseointegration of dental implants [J].
de Almeida, Marina Storani ;
Maciel, Carlos Dias ;
Pereira, Jose Carlos .
SENSORS, 2007, 7 (07) :1224-1237
[7]   Modeling dental implant insertion [J].
Dorogoy, A. ;
Rittel, D. ;
Shemtov-Yona, K. ;
Korabi, R. .
JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2017, 68 :42-50
[8]  
Drozdz M.B, 2008, EFFICIENT FINITE ELE, DOI [10.1034/j.1600-0501.2003.00937.x, DOI 10.1034/J.1600-0501.2003.00937.X]
[9]   A multiband approach for accurate numerical simulation of frequency dependent ultrasonic wave propagation in the time domain [J].
Egerton, J. S. ;
Lowe, M. J. S. ;
Huthwaite, P. ;
Halai, H. V. .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2017, 142 (03) :1270-1280
[10]   Biomechanical behaviours of the bone-implant interface: a review [J].
Gao, Xing ;
Fraulob, Manon ;
Haiat, Guillaume .
JOURNAL OF THE ROYAL SOCIETY INTERFACE, 2019, 16 (156)