Optimization and Development of Concurrent EEG-fMRI Data Acquisition Setup for Understanding Neural Mechanisms of Brain

被引:0
作者
Ahmad, Rana Fayyaz [1 ]
Malik, Aamir Saeed [1 ]
Kamel, Nidal [1 ]
Reza, Faruque [2 ]
Karim, Ahmad Helmy Abdul [3 ]
机构
[1] Univ Teknol PETRONAS, CISIR, Dept Elect & Elect Engn, Tronoh 31750, Perak, Malaysia
[2] Univ Sains Malaysia, Dept Neurosci, Kota Baharu 16150, Kelantan, Malaysia
[3] Univ Sains Malaysia, Dept Radiol, Kota Baharu 16150, Kelantan, Malaysia
来源
2015 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC) | 2015年
关键词
EEG; fMRI; Concurrent EEG-fMRI; BOLD; ARTIFACT;
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Electroencephalography (EEG) and functional magnetic resonance (fMRI) both are considered as non-invasive neuroimaging modalities. Both are used for understanding brain functionalities in cognitive neuroscience as well as in clinical applications. EEG gives high temporal resolution and it has poor spatial resolution. On the other hand, fMRI has very high spatial resolution and poor temporal resolution. For deep understanding of neural mechanisms inside human brain, it is desirable to get the higher spatiotemporal resolution of human brain at the same time. Concurrent EEG-fMRI data recording solve the problem of higher spatiotemporal resolution. It can be also helpful to understand the neural mechanism inside human brain effectively. The concurrent EEG-fMRI recording requires MRI compatible EEG equipment which can be placed inside the higher magnetic field of MRI scanner and also synchronization is required to make setup concurrent. To get higher signal to noise ratio (SNR), optimization of data acquisition parameters plays a significant role. In this paper, we discussed the some real issues during data acquisition and their optimization. We have developed the concurrent EEG-fMRI setup and also successfully recorded the EEG-fMRI data concurrently by optimizing the data acquisition parameters involved. Artifacts have been removed from the data and further, data fusion framework is proposed for combine analysis of EEG and fMRI data.
引用
收藏
页码:476 / 481
页数:6
相关论文
共 19 条
  • [1] A method for removing imaging artifact from continuous EEG recorded during functional MRI
    Allen, PJ
    Josephs, O
    Turner, R
    [J]. NEUROIMAGE, 2000, 12 (02) : 230 - 239
  • [2] Amin H. U., 2015, AUSTRALAS PHYS ENG S, P1
  • [3] [Anonymous], FRONTIERS NEUROSCIEN
  • [4] [Anonymous], OPTIMAL ICA ALGORITH
  • [5] Simultaneous intracranial EEG-fMRI in humans: Protocol considerations and data quality
    Carmichael, D. W.
    Vulliemoz, S.
    Rodionov, R.
    Thornton, J. S.
    McEvoy, A. W.
    Lemieux, L.
    [J]. NEUROIMAGE, 2012, 63 (01) : 301 - 309
  • [6] EEG and MEG: Relevance to Neuroscience
    da Silva, Fernando Lopes
    [J]. NEURON, 2013, 80 (05) : 1112 - 1128
  • [7] The benefits of simultaneous EEG-fMRI for EEG analysis
    Debener, Stefan
    De Vos, Maarten
    [J]. CLINICAL NEUROPHYSIOLOGY, 2011, 122 (02) : 217 - 218
  • [8] Joint ICA of ERP and fMRI during error-monitoring
    Edwards, Bethany G.
    Calhoun, Vince D.
    Kiehl, Kent A.
    [J]. NEUROIMAGE, 2012, 59 (02) : 1896 - 1903
  • [9] Ferdowsi S, 2013, INT CONF ACOUST SPEE, P6191, DOI 10.1109/ICASSP.2013.6638855
  • [10] CONTINUOUS EEG SIGNAL ANALYSIS FOR ASYNCHRONOUS BCI APPLICATION
    Hsu, Wei-Yen
    [J]. INTERNATIONAL JOURNAL OF NEURAL SYSTEMS, 2011, 21 (04) : 335 - 350