A pnCCD-based, fast direct single electron imaging camera for TEM and STEM

被引:84
作者
Ryll, H. [1 ]
Simson, M. [2 ]
Hartmann, R. [1 ]
Holl, P. [1 ]
Huth, M. [2 ]
Ihle, S. [2 ]
Kondo, Y. [3 ]
Kotula, P. [4 ]
Liebel, A. [2 ]
Mueller-Caspary, K. [5 ]
Rosenauer, A. [5 ]
Sagawa, R. [3 ]
Schmidt, J. [2 ]
Soltau, H. [2 ]
Strueder, L. [1 ,6 ]
机构
[1] PNSensor GmbH, Otto Hahn Ring 6, D-81739 Munich, Germany
[2] PNDetector GmbH, Otto Hahn Ring 6, D-81739 Munich, Germany
[3] JEOL Ltd, 3-1-2 Musashino, Akishima, Tokyo 1968558, Japan
[4] Sandia Natl Labs, POB 5800, Albuquerque, NM 87185 USA
[5] Univ Bremen, Otto Hahn Allee 1, D-28359 Bremen, Germany
[6] Univ Siegen, Walter Flex Str 3, D-57068 Siegen, Germany
来源
JOURNAL OF INSTRUMENTATION | 2016年 / 11卷
关键词
Pixelated detectors and associated VLSI electronics; Radiation-hard detectors; Solid state detectors; Very low-energy charged particle detectors; EFFICIENCY;
D O I
10.1088/1748-0221/11/04/P04006
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We report on a new camera that is based on a pnCCD sensor for applications in scanning transmission electron microscopy. Emerging new microscopy techniques demand improved detectors with regards to readout rate, sensitivity and radiation hardness, especially in scanning mode. The pnCCD is a 2D imaging sensor that meets these requirements. Its intrinsic radiation hardness permits direct detection of electrons. The pnCCD is read out at a rate of 1; 150 frames per second with an image area of 264 x 264 pixel. In binning or windowing modes, the readout rate is increased almost linearly, for example to 4; 000 frames per second at 4x binning (264 x 66 pixel). Single electrons with energies from 300 keV down to 5 keV can be distinguished due to the high sensitivity of the detector. Three applications in scanning transmission electron microscopy are highlighted to demonstrate that the pnCCD satisfies experimental requirements, especially fast recording of 2D images. In the first application, 65; 536 2D diffraction patterns were recorded in 70 s. STEM images corresponding to intensities of various diffraction peaks were reconstructed. For the second application, the microscope was operated in a Lorentz-like mode. Magnetic domains were imaged in an area of 256 x 256 sample points in less than 37 seconds for a total of 65; 536 images each with 264 x 132 pixels. Due to information provided by the two-dimensional images, not only the amplitude but also the direction of the magnetic field could be determined. In the third application, millisecond images of a semiconductor nanostructure were recorded to determine the lattice strain in the sample. A speed-up in measurement time by a factor of 200 could be achieved compared to a previously used camera system.
引用
收藏
页数:19
相关论文
共 33 条
  • [1] Applications of an energy-dispersive pnCCD for X-ray reflectivity: Investigation of interdiffusion in Fe-Pt multilayers
    Abboud, Ali
    Send, Sebastian
    Hartmann, Robert
    Strueder, Lothar
    Savan, Alan
    Ludwig, Alfred
    Zotov, Nikolay
    Pietsch, Ullrich
    [J]. PHYSICA STATUS SOLIDI A-APPLICATIONS AND MATERIALS SCIENCE, 2011, 208 (11): : 2601 - 2607
  • [2] Atomic model of the F420-reducing [NiFe] hydrogenase by electron cryo-microscopy using a direct electron detector
    Allegretti, Matteo
    Mills, Deryck J.
    McMullan, Greg
    Kuehlbrandt, Werner
    Vonck, Janet
    [J]. ELIFE, 2014, 3
  • [3] Direct electron detection yields cryo-EM reconstructions at resolutions beyond 3/4 Nyquist frequency
    Bammes, Benjamin E.
    Rochat, Ryan H.
    Jakana, Joanita
    Chen, Dong-Hua
    Chiu, Wah
    [J]. JOURNAL OF STRUCTURAL BIOLOGY, 2012, 177 (03) : 589 - 601
  • [4] Edwards A.B., 1943, REC AUST MUS, V21, P154
  • [5] Direct single electron detection with a CMOS detector for electron microscopy
    Faruqi, AR
    Henderson, R
    Pryddetch, M
    Allport, P
    Evans, A
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 546 (1-2) : 170 - 175
  • [6] THE X-RAY-ENERGY RESPONSE OF SILICON .A. THEORY
    FRASER, GW
    ABBEY, AF
    HOLLAND, A
    MCCARTHY, K
    OWENS, A
    WELLS, A
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 350 (1-2) : 368 - 378
  • [7] SEMICONDUCTOR DRIFT CHAMBER - AN APPLICATION OF A NOVEL CHARGE TRANSPORT SCHEME
    GATTI, E
    REHAK, P
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1984, 225 (03) : 608 - 614
  • [8] Hartmann R., 2007, MICROSC MICROANAL S2, V13, P436, DOI [10.1017/S143192760707821X, DOI 10.1017/S143192760707821X]
  • [9] Jones L., 2015, Microsc. Microanal, V21, P2411
  • [10] Krieger B, 2011, IEEE NUCL SCI CONF R, P1946, DOI 10.1109/NSSMIC.2011.6154391