Electron-Excited X-ray Microanalysis by Energy Dispersive Spectrometry at 50: Analytical Accuracy, Precision, Trace Sensitivity, and Quantitative Compositional Mapping

被引:21
作者
Newbury, Dale E. [1 ]
Ritchie, Nicholas W. M. [1 ]
机构
[1] NIST, Gaithersburg, MD 20899 USA
关键词
compositional mapping; electron-excited X-ray microanalysis; energy dispersive X-ray spectrometry; AUTOMATIC PEAK IDENTIFICATION; LOW BEAM ENERGY; PROBE MICROANALYSIS; CONSTITUENTS; INTENSITY; EDS;
D O I
10.1017/S143192761901482X
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
2018 marked the 50th anniversary of the introduction of energy dispersive X-ray spectrometry (EDS) with semiconductor detectors to electron-excited X-ray microanalysis. Initially useful for qualitative analysis, EDS has developed into a fully quantitative analytical tool that can match wavelength dispersive spectrometry for accuracy in the determination of major (mass concentration C > 0.1) and minor (0.01 <= C <= 0.1) constituents, and useful accuracy can extend well into the trace (0.001 < C < 0.01) constituent range even when severe peak interference occurs. Accurate analysis is possible for low atomic number elements (B, C, N, O, and F), and at low beam energy, which can optimize lateral and depth spatial resolution. By recording a full EDS spectrum at each picture element of a scan, comprehensive quantitative compositional mapping can also be performed.
引用
收藏
页码:1075 / 1105
页数:31
相关论文
共 33 条
[1]   The determination of the efficiency of energy dispersive X-ray spectrometers by a new reference material [J].
Alvisi, Marco ;
Blome, Markus ;
Griepentrog, Michael ;
Hodoroaba, Vasile-Dan ;
Karduck, Peter ;
Mostert, Marco ;
Nacucchi, Michele ;
Procop, Mathias ;
Rohde, Martin ;
Scholze, Frank ;
Statham, Peter ;
Terborg, Ralf ;
Thiot, Jean-Francois .
MICROSCOPY AND MICROANALYSIS, 2006, 12 (05) :406-415
[2]  
Castaing R., 1951, APPL ELECT PROBES LO
[3]   MICRO-ANALYSIS BY A FLYING-SPOT X-RAY METHOD [J].
COSSLETT, VE ;
DUNCUMB, P .
NATURE, 1956, 177 (4521) :1172-1173
[4]  
Fiori C. E., 1978, Scanning Electron Microscopy, 1978, P401
[5]   PREDICTION OF CONTINUUM INTENSITY IN ENERGY-DISPERSIVE X-RAY MICROANALYSIS [J].
FIORI, CE ;
MYKLEBUST, RL ;
HEINRICH, KFJ ;
YAKOWITZ, H .
ANALYTICAL CHEMISTRY, 1976, 48 (01) :172-176
[6]   A CMOS charge preamplifier for silicon drift detectors with on-chip JFET and feedback capacitor [J].
Fiorini, C. ;
Frizzi, T. ;
Longoni, A. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 568 (01) :322-328
[7]   SOLID-STATE ENERGY-DISPERSION SPECTROMETER FOR ELECTRON-MICROPROBE X-RAY ANALYSIS [J].
FITZGERALD, R ;
KEIL, K ;
HEINRICH, KF .
SCIENCE, 1968, 159 (3814) :528-+
[8]  
Goldstein J. I., 1975, PRACTICAL SCANNING E, DOI DOI 10.1007/978-1-4613-4422-3
[9]  
Goldstein J.I., 2018, SCANNING ELECT MICRO, P209
[10]   Low-Voltage Electron-Probe Microanalysis of Fe-Si Compounds Using Soft X-Rays [J].
Gopon, Phillip ;
Fournelle, John ;
Sobol, Peter E. ;
Llovet, Xavier .
MICROSCOPY AND MICROANALYSIS, 2013, 19 (06) :1698-1708