Alternative sample-introduction technique to avoid breakthrough in gradient-elution liquid chromatography of polymers

被引:15
|
作者
Reingruber, Eva [1 ]
Bedani, Filippo [2 ]
Buchberger, Wolfgang [1 ]
Schoenmakers, Peter [2 ]
机构
[1] Johannes Kepler Univ Linz, Inst Analyt Chem, A-4040 Linz, Austria
[2] Univ Amsterdam, Vant Hoff Inst Mol Sci, NL-1018 WV Amsterdam, Netherlands
关键词
Polymers; Liquid chromatography; Breakthrough; Gradient elution; RETENTION BEHAVIOR; SYNTHETIC-POLYMERS;
D O I
10.1016/j.chroma.2010.07.073
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Gradient-elution liquid chromatography (GELC) is a powerful tool for the characterization of synthetic polymers. However, gradient-elution chromatograms often suffer from breakthrough phenomena. Breakthrough can be averted by using a sample solvent as weak as the mobile phase. However, this approach is only applicable to polymers for which a sufficiently strong solvent exists which is at the same time a weak eluent. Finding such a solvent for a given polymer can be laborious or may even be impossible. Besides, when working with comprehensive two-dimensional LC the effluent of the first dimension is the injection solvent of the second dimension. In this case, it is not possible to avoid breakthrough by adjusting the eluent strength of the second-dimension injection solvent. Therefore, another strategy to avert breakthrough has to be implemented. In this work, we successfully avoided breakthrough in GELC by mixing the mobile phase not before, but after the autosampler. This was demonstrated measuring a blend of poly(methyl methacrylate) standards with different molecular-weights as model mixture with comprehensive two-dimensional GELC x size-exclusion chromatography. The strategy is thought to be applicable to all substances with a sufficiently strong dependence of retention on mobile-phase composition. This typically applies to large molecules (synthetic and natural polymers) and allows efficient refocusing. Unretained and barely retained substances are not refocused and therefore suffer in the proposed setup from peak broadening. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:6595 / 6598
页数:4
相关论文
共 10 条
  • [1] Recycling gradient-elution liquid chromatography for the analysis of chemical-composition distributions of polymers
    Niezen, Leon E.
    Staal, Bastiaan B. P.
    Lang, Christiane
    Philipsen, Harry J. A.
    Pirok, Bob W. J.
    Somsen, Govert W.
    Schoenmakers, Peter J.
    JOURNAL OF CHROMATOGRAPHY A, 2022, 1679
  • [2] Improved sample introduction approach in hydrophilic interaction liquid chromatography to avoid breakthrough of proteins
    Perez-Robles, Raquel
    Fekete, Szabolcs
    Kormany, Robert
    Navas, Natalia
    Guillarme, Davy
    JOURNAL OF CHROMATOGRAPHY A, 2024, 1713
  • [3] A STATISTICAL APPROACH TO ESTIMATING ADSORPTION-ISOTHERM PARAMETERS IN GRADIENT-ELUTION PREPARATIVE LIQUID CHROMATOGRAPHY
    Su, Jiaji
    Yao, Zhigang
    Li, Cheng
    Zhang, Ye
    ANNALS OF APPLIED STATISTICS, 2023, 17 (04) : 3476 - 3499
  • [4] Retention mechanism, isocratic and gradient-elution separation and characterization of (co)polymers in normal-phase and reversed-phase high-performance liquid chromatography
    Jandera, P
    Holcapek, M
    Kolárová, L
    JOURNAL OF CHROMATOGRAPHY A, 2000, 869 (1-2) : 65 - 84
  • [5] Determination of retention factors of aromatic compounds by gradient-elution reverse-phase high performance liquid chromatography
    Ju Weon Lee
    Kyung Ho Row
    Korean Journal of Chemical Engineering, 2002, 19 : 978 - 985
  • [6] Determination of retention factors of aromatic compounds by gradient-elution reverse-phase high performance liquid chromatography
    Lee, JW
    Row, KH
    KOREAN JOURNAL OF CHEMICAL ENGINEERING, 2002, 19 (06) : 978 - 985
  • [7] Prediction of retention in gradient-elution normal-phase high-performance liquid chromatography with binary solvent gradients
    Jandera, P
    Kucerova, M
    JOURNAL OF CHROMATOGRAPHY A, 1997, 759 (1-2) : 13 - 25
  • [8] SAMPLE INJECTION CONDITIONS FOR PREPARATIVE LIQUID-CHROMATOGRAPHY - EXISTENCE OF OPTIMUM PARAMETERS FOR GRADIENT ELUTION
    CRETIER, G
    ELKHABCHI, M
    ROCCA, JL
    ANALUSIS, 1991, 19 (07) : 220 - 222
  • [9] Prediction of the retention of s-triazines in reversed-phase high-performance liquid chromatography under linear gradient-elution conditions
    D'Archivio, Angelo Antonio
    Maggi, Maria Anna
    Ruggieri, Fabrizio
    JOURNAL OF SEPARATION SCIENCE, 2014, 37 (15) : 1930 - 1936
  • [10] Characterisation and prediction of retention in isocratic and gradient-elution normal-phase high-performance liquid chromatography on polar bonded stationary phases with binary and ternary solvent systems
    Jandera, P
    Petránek, L
    Kucerová, M
    JOURNAL OF CHROMATOGRAPHY A, 1997, 791 (1-2) : 1 - 19