Application of the FreeStyle®Libre Glucose Monitoring System in type 1 diabetes mellitus patients aged 1-4 years

被引:3
作者
Li, Yangshiyu [1 ]
Cao, Bingyan [2 ]
Chen, Qiong [1 ]
Du, Mengmeng [1 ]
Yan, Mingming [3 ]
Chen, Yongxing [1 ]
Wei, Haiyan [1 ]
Wu, Xue [1 ]
Cui, Yan [1 ]
Liu, Fang [1 ]
机构
[1] Zhengzhou Univ, Henan Childrens Hosp, Zhengzhou Childrens Hosp, Dept Endocrinol Genet & Metab,Childrens Hosp, Zhengzhou 450018, Peoples R China
[2] Capital Med Univ, Beijing Childrens Hosp, Natl Ctr Childrens Hlth, Dept Endocrinol Genet & Metab, Beijing, Peoples R China
[3] Zhengzhou Univ, Henan Childrens Hosp, Zhengzhou Childrens Hosp, Dept Stat & Epidemiol,Childrens Hosp, Zhengzhou, Peoples R China
关键词
blood glucose self-monitoring; child; diabetes mellitus; type; 1; personal satisfaction; RAPIDLY RISING INCIDENCE; ENDOCRINE-SOCIETY; MANAGEMENT; CHILDREN;
D O I
10.1111/pedi.13368
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background To investigate the analytical accuracy, safety performance, and user satisfaction (guardians of study participants) of the FreeStyle (R) Libre Glucose Monitoring System in the treatment of type 1 diabetes mellitus (T1DM), in children aged T1DM, aged 4 months to 4 years, were enrolled in this study. Patients wore the sensor for 14 days; sensor scans were performed immediately and at 5, 10, and 15 min after capillary blood glucose (BG) measurements to evaluate the effectiveness of the device and the lag effect. Results The consensus error grid showed that 96.40% of values fell within zone A (no clinical impact) and 3.60% within zone B (little/no clinical impact). Overall, the mean absolute relative difference (MARD) was 9.34%, and was higher in the capillary BG <4.0 mmol/L group (15.18%) than in the 4-10 mmol/L (9.63%) and >10 mmol/L (7.17%) groups. The MARD increased gradually with scanning time extension, indicating a short lag effect. Regression analysis showed that a higher BG level was associated with a greater difference in FreeStyle (R) Libre System measurements. Conclusions The use of the FreeStyle (R) Libre System in children aged 1-4 years is accurate and safe, and may be accurate down to 4 months, independent of patient characteristics.
引用
收藏
页码:604 / 610
页数:7
相关论文
共 18 条
  • [11] Patients' evaluation of nocturnal hypoglycaemia with GlucoDay continuous glucose monitoring in paediatric patients
    Meschi, Franco
    Bonfanti, Riccardo
    Rigamonti, Andrea
    Giulio, Frontino
    Battaglino, Roseila
    Viscardi, Matteo
    Poscia, Alessandro
    Chiumello, Giuseppe
    [J]. ACTA DIABETOLOGICA, 2010, 47 (04) : 295 - 300
  • [12] Performance of a Factory-Calibrated Real-Time Continuous Glucose Monitoring System Utilizing an Automated Sensor Applicator
    Shah, Viral N.
    Laffel, Lori M.
    Wadwa, R. Paul
    Garg, Satish K.
    [J]. DIABETES TECHNOLOGY & THERAPEUTICS, 2018, 20 (06) : 428 - 433
  • [13] Accuracy of a Fourth-Generation Continuous Glucose Monitoring System in Children and Adolescents with Type 1 Diabetes
    Slover, Robert H.
    Tryggestad, Jeanie B.
    DiMeglio, Linda A.
    Fox, Larry A.
    Bode, Bruce W.
    Bailey, Timothy S.
    Brazg, Ronald
    Christiansen, Mark P.
    Sherr, Jennifer L.
    Tsalikian, Eva
    Kaiserman, Kevin B.
    Sullivan, Ashley
    Huang, Suiying
    Shin, John
    Lee, Scott W.
    Kaufman, Francine R.
    [J]. DIABETES TECHNOLOGY & THERAPEUTICS, 2018, 20 (09) : 576 - 584
  • [14] Impact of factory-calibrated Freestyle Libre System with new glucose algorithm measurement accuracy and clinical performance in children with type 1 diabetes during summer camp
    Szadkowska, Agnieszka
    Michalak, Arkadiusz
    Losiewicz, Aleksandra
    Kusmierczyk, Hanna
    Krawczyk-Rusiecka, Kinga
    Chrzanowski, Jedrzej
    Gawrecki, Andrzej
    Zozulinska-Ziolkiewicz, Dorota
    Fendler, Wojciech
    [J]. PEDIATRIC DIABETES, 2021, 22 (02) : 261 - 270
  • [15] Flash Glucose Measurements in Children with Type 1 Diabetes in Real-Life Settings: To Trust or Not to Trust?
    Szadkowska, Agnieszka
    Gawrecki, Andrzej
    Michalak, Arkadiusz
    Zozulinska-Ziolkiewicz, Dorota
    Fendler, Wojciech
    Mlynarski, Wojciech
    [J]. DIABETES TECHNOLOGY & THERAPEUTICS, 2018, 20 (01) : 17 - 24
  • [16] Recommendations from the Pediatric Endocrine Society for Evaluation and Management of Persistent Hypoglycemia in Neonates, Infants, and Children
    Thornton, Paul S.
    Stanley, Charles A.
    De Leon, Diva D.
    Harris, Deborah
    Haymond, Morey W.
    Hussain, Khalid
    Levitsky, Lynne L.
    Murad, Mohammad H.
    Rozance, Paul J.
    Simmons, Rebecca A.
    Sperling, Mark A.
    Weinstein, David A.
    White, Neil H.
    Wolfsdorf, Joseph I.
    [J]. JOURNAL OF PEDIATRICS, 2015, 167 (02) : 238 - 245
  • [17] Rapidly rising incidence of Type 1 diabetes in children and adolescents aged 0-19 years in Zhejiang, China, 2007 to 2013
    Wu, H. B.
    Zhong, J. M.
    Hu, R. Y.
    Wang, H.
    Gong, W. W.
    Pan, J.
    Fei, F. R.
    Wang, M.
    Guo, L. H.
    Yang, L.
    Yu, M.
    [J]. DIABETIC MEDICINE, 2016, 33 (10) : 1339 - 1346
  • [18] Rapidly rising incidence of childhood type 1 diabetes in Chinese population: epidemiology in Shanghai during 1997-2011
    Zhao, Zhuhui
    Sun, Chengjun
    Wang, Chunfang
    Li, Pin
    Wang, Wei
    Ye, Jun
    Gu, Xuefan
    Wang, Xiaodong
    Shen, Shuixian
    Zhi, Dijing
    Lu, Zhong
    Ye, Rong
    Cheng, Ruoqian
    Xi, Li
    Li, Xiaojing
    Zheng, Zhangqian
    Zhang, Miaoying
    Luo, Feihong
    [J]. ACTA DIABETOLOGICA, 2014, 51 (06) : 947 - 953