CT and MRI of hip arthroplasty

被引:74
作者
Cahir, J. G.
Toms, A. P.
Marshall, T. J.
Wimhurst, J.
Nolan, J.
机构
[1] Norfolk & Norwich Univ Hosp, Dept Radiol, Norwich NR4 7UY, Norfolk, England
[2] Norfolk & Norwich Univ Hosp, Dept Orthopaed, Norwich NR4 7UY, Norfolk, England
关键词
METAL ARTIFACT REDUCTION; ACETABULAR OSTEOLYSIS; COMPUTED-TOMOGRAPHY; MAGNETIC-RESONANCE; JOINT REPLACEMENTS; POSTERIOR APPROACH; PELVIC OSTEOLYSIS; SOFT-TISSUE; WEAR; ALGORITHM;
D O I
10.1016/j.crad.2007.04.018
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Plain films are the initial imaging method of choice for evaluation of hip arthroplasty. Recent advances in technology and imaging techniques have largely overcome the problems of beam hardening in computed tomography (CT) and magnetic susceptibility artefact in magnetic resonance imaging (MRI). CT and MRI have now become useful imaging techniques in the assessment of hip arthroplasty. (c) 2007 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:1163 / 1171
页数:9
相关论文
共 32 条
[1]   Wear and osteolysis in total joint replacements [J].
Aspenberg, P ;
Kadoya, Y ;
Kobayashi, A ;
Ohashi, H .
ACTA ORTHOPAEDICA SCANDINAVICA, 1998, 69 (04) :435-436
[2]   Pelvic discontinuity in revision total hip arthroplasty [J].
Berry, DJ ;
Lewallen, DG ;
Hanssen, AD ;
Cabanela, ME .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1999, 81A (12) :1692-1702
[3]   Osteolysis of the pelvis - Evaluation and treatment [J].
Chiang, PP ;
Burke, DW ;
Freiberg, AA ;
Rubash, HE .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2003, (417) :164-174
[4]   Management of patients with acetabular socket wear and pelvic osteolysis [J].
Claus, AM ;
Walde, TA ;
Leung, SB ;
Wolf, RL ;
Engh, CA .
JOURNAL OF ARTHROPLASTY, 2003, 18 (03) :112-117
[5]   Painful infection at the site of hip prosthesis:: CT imaging [J].
Cyteval, C ;
Hamm, V ;
Sarrabère, MP ;
Lopez, FM ;
Maury, P ;
Taourel, P .
RADIOLOGY, 2002, 224 (02) :477-483
[6]  
Czerny C, 1999, Top Magn Reson Imaging, V10, P214, DOI 10.1097/00002142-199908000-00003
[7]   An unusual lymphocytic perivascular infiltration in tissues around contemporary metal-on-metal joint replacements [J].
Davies, AP ;
Willert, HG ;
Campbell, PA ;
Learmonth, ID ;
Case, CP .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2005, 87A (01) :18-27
[8]   A simple capsulorrhaphy in a posterior approach for total hip arthroplasty [J].
Dixon, MC ;
Scott, RD ;
Schai, PA ;
Stamos, V .
JOURNAL OF ARTHROPLASTY, 2004, 19 (03) :373-376
[9]   FEMORAL COMPONENT LOOSENING USING CONTEMPORARY TECHNIQUES OF FEMORAL CEMENT FIXATION [J].
HARRIS, WH ;
MCCARTHY, JC ;
ONEILL, DA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1982, 64 (07) :1063-1067
[10]   Pain related to the psoas muscle after total hip replacement [J].
Jasani, V ;
Richards, P ;
Wynn-Jones, C .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2002, 84B (07) :991-993