Magnetic Particle Imaging for High Temporal Resolution Assessment of Aneurysm Hemodynamics

被引:48
作者
Sedlacik, Jan [1 ]
Froelich, Andreas [1 ]
Spallek, Johanna [2 ]
Forkert, Nils D. [3 ,4 ]
Faizy, Tobias D. [1 ]
Werner, Franziska [5 ,6 ]
Knopp, Tobias [5 ,6 ]
Krause, Dieter [2 ]
Fiehler, Jens [1 ]
Buhk, Jan-Hendrik [1 ]
机构
[1] Univ Med Ctr Hamburg Eppendorf, Dept Neuroradiol, Hamburg, Germany
[2] Hamburg Univ Technol, Dept Prod Dev & Mech Engn Design, Hamburg, Germany
[3] Univ Calgary, Dept Radiol, Calgary, AB, Canada
[4] Univ Calgary, Hotchkiss Brain Inst, Calgary, AB, Canada
[5] Univ Med Ctr Hamburg Eppendorf, Sect Biomed Imaging, Hamburg, Germany
[6] Hamburg Univ Technol, Inst Biomed Imaging, Hamburg, Germany
关键词
D O I
10.1371/journal.pone.0160097
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Purpose The purpose of this work was to demonstrate the capability of magnetic particle imaging (MPI) to assess the hemodynamics in a realistic 3D aneurysm model obtained by additive manufacturing. MPI was compared with magnetic resonance imaging (MRI) and dynamic digital subtraction angiography (DSA). Materials and Methods The aneurysm model was of saccular morphology (7 mm dome height, 5 mm cross-section, 3-4 mm neck, 3.5 mm parent artery diameter) and connected to a peristaltic pump delivering a physiological flow (250 mL/min) and pulsation rate (70/min). High-resolution (4 h long) 4D phase contrast flow quantification (4D pc-fq) MRI was used to directly assess the hemodynamics of the model. Dynamic MPI, MRI, and DSA were performed with contrast agent injections (3 mL volume in 3 s) through a proximally placed catheter. Results and Discussion 4D pc-fq measurements showed distinct pulsatile flow velocities (20-80 cm/s) as well as lower flow velocities and a vortex inside the aneurysm. All three dynamic methods (MPI, MRI, and DSA) also showed a clear pulsation pattern as well as delayed contrast agent dynamics within the aneurysm, which is most likely caused by the vortex within the aneurysm. Due to the high temporal resolution of MPI and DSA, it was possible to track the contrast agent bolus through the model and to estimate the average flow velocity (about 60 cm/s), which is in accordance with the 4D pc-fq measurements. Conclusions The ionizing radiation free, 4D high resolution MPI method is a very promising tool for imaging and characterization of hemodynamics in human. It carries the possibility of overcoming certain disadvantages of other modalities like considerably lower temporal resolution of dynamic MRI and limited 2D characteristics of DSA. Furthermore, additive manufacturing is the key for translating powerful pre-clinical techniques into the clinic.
引用
收藏
页数:12
相关论文
共 23 条
[1]   Three-dimensional printing of anatomically accurate, patient specific intracranial aneurysm models [J].
Anderson, Jeff R. ;
Thompson, Walker L. ;
Alkattan, Abdulaziz K. ;
Diaz, Orlando ;
Klucznik, Richard ;
Zhang, Yi J. ;
Britz, Gavin W. ;
Grossman, Robert G. ;
Karmonik, Christof .
JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2016, 8 (05) :517-520
[2]   Quantification of arterial flow using digital subtraction angiography [J].
Bonnefous, Odile ;
Pereira, Vitor Mendes ;
Ouared, Rafik ;
Brina, Olivier ;
Aerts, Hans ;
Hermans, Roel ;
van Nijnatten, Fred ;
Stawiaski, Jean ;
Ruijters, Daniel .
MEDICAL PHYSICS, 2012, 39 (10) :6264-6275
[3]   Risk Factors for Growth of Intracranial Aneurysms: A Systematic Review and Meta-Analysis [J].
Brinjikji, W. ;
Zhu, Y. -Q. ;
Lanzino, G. ;
Cloft, H. J. ;
Murad, M. H. ;
Wang, Z. ;
Kallmes, D. F. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2016, 37 (04) :615-620
[4]   Neurovascular Modeling: Small-Batch Manufacturing of Silicone Vascular Replicas [J].
Chueh, J. Y. ;
Wakhloo, A. K. ;
Gounis, M. J. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2009, 30 (06) :1159-1164
[5]   Magnetic Particle Imaging With Tailored Iron Oxide Nanoparticle Tracers [J].
Ferguson, R. Matthew ;
Khandhar, Amit P. ;
Kemp, Scott J. ;
Arami, Hamed ;
Saritas, Emine U. ;
Croft, Laura R. ;
Konkle, Justin ;
Goodwill, Patrick W. ;
Halkola, Aleksi ;
Rahmer, Juergen ;
Borgert, Joern ;
Conolly, Steven M. ;
Krishnan, Kannan M. .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2015, 34 (05) :1077-1084
[6]   3D Printing of Intracranial Aneurysms Using Fused Deposition Modeling Offers Highly Accurate Replications [J].
Froelich, A. M. J. ;
Spallek, J. ;
Brehmer, L. ;
Buhk, J. -H. ;
Krause, D. ;
Fiehler, J. ;
Kemmling, A. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2016, 37 (01) :120-124
[7]   Tomographic imaging using the nonlinear response of magnetic particles [J].
Gleich, B ;
Weizenecker, R .
NATURE, 2005, 435 (7046) :1214-1217
[8]   Magnetic Particle Imaging: Visualization of Instruments for Cardiovascular Intervention [J].
Haegele, Julian ;
Rahmer, Juergen ;
Gleich, Bernhard ;
Borgert, Joern ;
Wojtczyk, Hanne ;
Panagiotopoulos, Nikolaos ;
Buzug, Thorsten M. ;
Barkhausen, Joerg ;
Vogt, Florian M. .
RADIOLOGY, 2012, 265 (03) :933-938
[9]   Hemodynamics of Cerebral Aneurysms: Computational Analyses of Aneurysm Progress and Treatment [J].
Jeong, Woowon ;
Rhee, Kyehan .
COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE, 2012, 2012
[10]   Combined Preclinical Magnetic Particle Imaging and Magnetic Resonance Imaging: Initial Results in Mice [J].
Kaul, M. G. ;
Weber, O. ;
Heinen, U. ;
Reitmeier, A. ;
Mummert, T. ;
Jung, C. ;
Raabe, N. ;
Knopp, T. ;
Ittrich, H. ;
Adam, G. .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2015, 187 (05) :347-352