Magnetic Particle Imaging for High Temporal Resolution Assessment of Aneurysm Hemodynamics

被引:48
|
作者
Sedlacik, Jan [1 ]
Froelich, Andreas [1 ]
Spallek, Johanna [2 ]
Forkert, Nils D. [3 ,4 ]
Faizy, Tobias D. [1 ]
Werner, Franziska [5 ,6 ]
Knopp, Tobias [5 ,6 ]
Krause, Dieter [2 ]
Fiehler, Jens [1 ]
Buhk, Jan-Hendrik [1 ]
机构
[1] Univ Med Ctr Hamburg Eppendorf, Dept Neuroradiol, Hamburg, Germany
[2] Hamburg Univ Technol, Dept Prod Dev & Mech Engn Design, Hamburg, Germany
[3] Univ Calgary, Dept Radiol, Calgary, AB, Canada
[4] Univ Calgary, Hotchkiss Brain Inst, Calgary, AB, Canada
[5] Univ Med Ctr Hamburg Eppendorf, Sect Biomed Imaging, Hamburg, Germany
[6] Hamburg Univ Technol, Inst Biomed Imaging, Hamburg, Germany
来源
PLOS ONE | 2016年 / 11卷 / 08期
关键词
D O I
10.1371/journal.pone.0160097
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Purpose The purpose of this work was to demonstrate the capability of magnetic particle imaging (MPI) to assess the hemodynamics in a realistic 3D aneurysm model obtained by additive manufacturing. MPI was compared with magnetic resonance imaging (MRI) and dynamic digital subtraction angiography (DSA). Materials and Methods The aneurysm model was of saccular morphology (7 mm dome height, 5 mm cross-section, 3-4 mm neck, 3.5 mm parent artery diameter) and connected to a peristaltic pump delivering a physiological flow (250 mL/min) and pulsation rate (70/min). High-resolution (4 h long) 4D phase contrast flow quantification (4D pc-fq) MRI was used to directly assess the hemodynamics of the model. Dynamic MPI, MRI, and DSA were performed with contrast agent injections (3 mL volume in 3 s) through a proximally placed catheter. Results and Discussion 4D pc-fq measurements showed distinct pulsatile flow velocities (20-80 cm/s) as well as lower flow velocities and a vortex inside the aneurysm. All three dynamic methods (MPI, MRI, and DSA) also showed a clear pulsation pattern as well as delayed contrast agent dynamics within the aneurysm, which is most likely caused by the vortex within the aneurysm. Due to the high temporal resolution of MPI and DSA, it was possible to track the contrast agent bolus through the model and to estimate the average flow velocity (about 60 cm/s), which is in accordance with the 4D pc-fq measurements. Conclusions The ionizing radiation free, 4D high resolution MPI method is a very promising tool for imaging and characterization of hemodynamics in human. It carries the possibility of overcoming certain disadvantages of other modalities like considerably lower temporal resolution of dynamic MRI and limited 2D characteristics of DSA. Furthermore, additive manufacturing is the key for translating powerful pre-clinical techniques into the clinic.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Moving table magnetic particle imaging: a stepwise approach preserving high spatio-temporal resolution
    Szwargulski, Patryk
    Gdaniec, Nadine
    Graeser, Matthias
    Moeddel, Martin
    Griese, Florian
    Krishnan, Kannan M.
    Buzug, Thorsten M.
    Knopp, Tobias
    JOURNAL OF MEDICAL IMAGING, 2018, 5 (04)
  • [2] High resolution magnetic particle imaging with low density trajectory
    Omer, Osama A.
    Medimagh, Hanne
    Buzug, Thorsten M.
    2015 5TH INTERNATIONAL WORKSHOP ON MAGNETIC PARTICLE IMAGING (IWMPI), 2015, : O10 - O10
  • [3] Investigating the cortical hemodynamics with high spatio-temporal resolution by optical imaging techniques
    Li, Pengcheng
    Luo, Qingming
    AOE 2007: ASIA OPTICAL FIBER COMMUNICATION & OPTOELECTRONIC EXPOSITION & CONFERENCE, CONFERENCE PROCEEDINGS, 2008, : 290 - 292
  • [4] In Vivo Assessment of Murine Elastase-induced Abdominal Aortic Aneurysm with High Resolution Magnetic Resonance Imaging
    Bartoli, M. A.
    Kober, F.
    Cozzone, R.
    Thompson, R. W.
    Alessi, M. C.
    Bernard, M.
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2012, 44 (05) : 475 - 481
  • [5] Magnetic imaging with femtosecond temporal resolution
    Li, Jie
    Lee, Min-Sang
    He, Wei
    Redeker, Bjoern
    Remhof, Arndt
    Amaladass, Edward
    Hassel, Christoph
    Eimueller, Thomas
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2009, 80 (07):
  • [6] HIGH-RESOLUTION MAGNETIC-RESONANCE-IMAGING OF THE TEMPORAL BONE
    JAGER, LJ
    MULLERLISSE, U
    REISER, M
    GREVERS, G
    LARYNGO-RHINO-OTOLOGIE, 1994, 73 (07) : 385 - 389
  • [7] High temporal resolution MR imaging in the assessment of mammographically suspicious microcalcifications
    Newstead, GM
    Yang, C
    Medved, M
    Abe, H
    Karczmar, GS
    Schmidt, RA
    Zamora, MA
    Foxley, S
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 184 (04) : 56 - 56
  • [8] Magnetic resonance imaging with submillisecond temporal resolution
    Zhong, Zheng
    Sun, Kaibao
    Karaman, M. Muge
    Zhou, Xiaohong Joe
    MAGNETIC RESONANCE IN MEDICINE, 2021, 85 (05) : 2434 - 2444
  • [9] HIGH-RESOLUTION MAGNETIC-RESONANCE-IMAGING OF THE HUMAN TEMPORAL BONE
    KOIZUKA, I
    SEO, R
    SANO, M
    MATSUNAGA, T
    MURAKAMI, M
    SEO, Y
    WATARI, H
    ORL-JOURNAL FOR OTO-RHINO-LARYNGOLOGY AND ITS RELATED SPECIALTIES, 1991, 53 (06): : 357 - 361
  • [10] Determining the resolution of a tracer for magnetic particle imaging by means of magnetic particle spectroscopy
    Remmo, Amani
    Wiekhorst, Frank
    Kosch, Olaf
    Lyer, Stefan
    Unterweger, Harald
    Kratz, Harald
    Loewa, Norbert
    RSC ADVANCES, 2023, 13 (23) : 15730 - 15736