Visual quality and performance comparison between 2 refractive rotationally asymmetric multifocal intraocular lenses

被引:34
作者
McNeely, Richard N. [1 ,2 ]
Pazo, Eric [1 ,2 ]
Spence, Andrew [1 ]
Richoz, Olivier [1 ]
Nesbit, M. Andrew [2 ]
Moore, Tara C. B. [2 ]
Moore, Jonathan E. [1 ,2 ]
机构
[1] Cathedral Eye Clin, 89-91 Acad St, Belfast BT1 2LS, Antrim, North Ireland
[2] Univ Ulster, Biomed Sci Res Inst, Coleraine, Londonderry, North Ireland
关键词
PATIENT SATISFACTION; BILATERAL IMPLANTATION; CLINICAL-OUTCOMES; HOFFER-Q; FORMULA; VISION; SRK/T; IOLS; EYES;
D O I
10.1016/j.jcrs.2017.05.039
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare the 12-month postoperative quality of vision and visual performance of 2 different refractive rotationally asymmetric multifocal intraocular lenses (IOLs). Setting: Cathedral Eye Clinic, Belfast, Northern Ireland, United Kingdom. Design: Retrospective case series. Methods: Refractive lens exchange (RLE) patients were divided into 2 groups. Group A comprised eyes receiving a Lentis Mplus LS-312 MF30 IOL and Group B, eyes receiving a Lenstec SBL-3 IOL. Refraction, uncorrected (UDVA) and corrected distance visual acuities, uncorrected intermediate (UIVA) and near (UNVA) visual acuities, distance-corrected intermediate and near (DCNVA) visual acuities, and quality of vision were evaluated preoperatively and up to 12 months postoperatively. Results: Each group comprised 90 eyes. Both groups had a high level of quality of vision 12 months postoperatively with no significant difference between the 2 groups (P = .919). There was no significant between-group difference in mean monocular and binocular UDVA, monocular UIVA, or monocular UNVA. Group B had statistically significantly better mean monocular DCNVA (P = .049), binocular UNVA (P = .011), and binocular DCNVA (P = .035). Group B had a higher percentage of complete spectacle independence. Conclusions: Both refractive rotationally asymmetric multifocal IOLs provided an excellent level of quality of vision 12 months postoperatively. Both IOL models restored distance, intermediate, and near visual function; however the IOLs in Group B provided better near visual performance. (C) 2017 ASCRS and ESCRS
引用
收藏
页码:1020 / 1026
页数:7
相关论文
共 23 条
  • [1] Alió JL, 2014, ESSENT OPHTHALMOL, P47, DOI 10.1007/978-3-319-09219-5_5
  • [2] Clinical and Optical Intraocular Performance of Rotationally Asymmetric Multifocal IOL Plate-Haptic Design Versus C-Loop Haptic Design
    Alio, Jorge L.
    Plaza-Puche, Ana B.
    Javaloy, Jaime
    Jose Ayala, Maria
    Vega-Estrada, Alfredo
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2013, 29 (04) : 252 - 259
  • [3] Visual outcomes with a single-optic accommodating intraocular lens and a low-addition-power rotational asymmetric multifocal intraocular lens
    Alio, Jorge L.
    Plaza-Puche, Ana B.
    Montalban, Raul
    Javaloy, Jaime
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (06) : 978 - 985
  • [4] Comparison of a New Refractive Multifocal Intraocular Lens with an Inferior Segmental Near Add and a Diffractive Multifocal Intraocular Lens
    Alio, Jorge L.
    Plaza-Puche, Ana B.
    Javaloy, Jaime
    Jose Ayala, Maria
    Moreno, Luis J.
    Pinero, David P.
    [J]. OPHTHALMOLOGY, 2012, 119 (03) : 555 - 563
  • [5] Comparative analysis of the clinical outcomes with 2 multifocal intraocular lens models with rotational asymmetry
    Alio, Jorge L.
    Plaza-Puche, Ana B.
    Pinero, David P.
    Javaloy, Jaime
    Jose Ayala, Maria
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (09) : 1605 - 1614
  • [6] Visual outcomes and optical performance of a monofocal intraocular lens and a new-generation multifocal intraocular lens
    Alio, Jorge L.
    Pinero, David P.
    Plaza-Puche, Ana B.
    Joanna Rodriguez, Maria
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (02) : 241 - 250
  • [7] Formula choice: Hoffer Q, Holladay 1, or SRK/T and refractive outcomes in 8108 eyes after cataract surgery with biometry by partial coherence interferometry
    Aristodemou, Petros
    Cartwright, Nathaniel E. Knox
    Sparrow, John M.
    Johnston, Robert L.
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (01) : 63 - 71
  • [8] The estimation of approximate sample size requirements necessary for clinical and epidemiological studies in vision sciences
    Goodall, E. A.
    Moore, J.
    Moore, T.
    [J]. EYE, 2009, 23 (07) : 1589 - 1597
  • [9] HOFFER KJ, 1994, J CATARACT REFR SURG, V20, P677