Preparation and evaluation of maltose modified polymer-silica composite based on cross-linked poly glycidyl methacrylate as high performance liquid chromatography stationary phase

被引:26
作者
Chu, Zhanying [1 ]
Zhang, Lingyi [1 ]
Zhang, Weibing [1 ]
机构
[1] East China Univ Sci & Technol, Shanghai Key Lab Funct Mat Chem, Sch Chem & Mol Engn, Shanghai 200237, Peoples R China
基金
中国国家自然科学基金;
关键词
Polymer-silica composite stationary phase; In-situ cross-linking polymerization; Mixed-mode separation; High performance liquid chromatography; HYDROPHILIC INTERACTION CHROMATOGRAPHY; TRANSFER RADICAL POLYMERIZATION; MIXED TRIFUNCTIONAL SILANES; OF-THE-ART; HORIZONTAL POLYMERIZATION; MAGNETIC NANOPARTICLES; POROUS SILICA; SURFACE; SEPARATION; BRUSHES;
D O I
10.1016/j.aca.2018.06.027
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new maltose modified polymer-silica composite was fabricated and applied as high performance liquid chromatography (HPLC) stationary phase. The cross-linked poly glycidyl methacrylate (pGMA) layer was chemically bonded to the outer surface as well as pore inner surface of silica beads via in-situ polymerization, and then maltose was modified onto the polymer layer via a [3 + 2] "click" reaction. The porous spherical silica (4 mu m diameter) with 300 A pore size was selected as the matrix so that the 3.25 nm-thick polymer layer fabricated on the pore inner surface would not affect its permeability. The typical 'U-shape' retention curves indicated a mixed-mode retention mechanism of the as-synthesized stationary phase. Both polar and non-polar analytes could be well separated on the stationary phase with column efficiency reaching 123809 plates/m for guanosine in hydrophilic interaction liquid chromatography (HILIC) mode and 46808 plates/m for fluorene in reversed-phase liquid chromatography (RPLC) mode, respectively. Nucleotides and their bases were baseline separated with good peak shape without any buffer salt in mobile phase, suggesting the effective shielding of the silanol groups. The packing material also showed excellent chromatographic repeatability with intraday RSDs of the retention time of five nucleosides less than 0.048% (n = 3) and interday RSDs less than 0.33% (n = 7) and great pH stability (from 1.5 to 10.2). Finally, the stationary phase was applied to the separation of ginseng extract. (c) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:179 / 186
页数:8
相关论文
共 48 条
[1]   Zwitterionic Poly(amino acid methacrylate) Brushes [J].
Alswieleh, Abdullah M. ;
Cheng, Nan ;
Canton, Irene ;
Ustbas, Burcin ;
Xue, Xuan ;
Ladmiral, Vincent ;
Xia, Sijing ;
Ducker, Robert E. ;
El Zubir, Osama ;
Cartron, Michael L. ;
Hunter, C. Neil ;
Leggett, Graham J. ;
Armes, Steven P. .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2014, 136 (26) :9404-9413
[2]   Spectroscopic and chromatographic characterisation of a pentafluorophenylpropyl silica phase end-capped in supercritical carbon dioxide as a reaction solvent [J].
Ashu-Arrah, Benjamin A. ;
Glennon, Jeremy D. ;
Albert, Klaus .
JOURNAL OF CHROMATOGRAPHY A, 2013, 1298 :86-94
[3]   Preparation and application of covalently bonded polysaccharidemodified stationary phase for per aqueous liquid chromatography [J].
Chen, Tong ;
Zhu, Ling ;
Lu, Huiyuan ;
Song, Guangsan ;
Li, Yuanyuan ;
Zhou, Hongbin ;
Li, Ping ;
Zhu, Wanning ;
Xu, Hechen ;
Shao, Lijun .
ANALYTICA CHIMICA ACTA, 2017, 964 :195-202
[4]   Review on the chemical and thermal stability of stationary phases for reversed-phase liquid chromatography [J].
Claessens, HA ;
van Straten, MA .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1060 (1-2) :23-41
[5]   Improved chemical stabilities for end-capped high performance liquid chromatography stationary phases based on poly(methyloctadecylsiloxane) thermally immobilized onto metalized silicas [J].
da Silva, Carla G. A. ;
Collins, Carol H. .
JOURNAL OF CHROMATOGRAPHY A, 2012, 1260 :81-87
[6]   Preparation of hydrophilic polymer-grafted polystyrene beads for hydrophilic interaction chromatography via surface-initiated atom transfer radical polymerization [J].
Dai, Xiaojun ;
He, Yuan ;
Wei, Yinmao ;
Gong, Bolin .
JOURNAL OF SEPARATION SCIENCE, 2011, 34 (22) :3115-3122
[7]   Hydrophilic interaction/weak cation-exchange mixed-mode chromatography for chitooligosaccharides separation [J].
Dong, Xuefang ;
Shen, Aijin ;
Gou, Zhimou ;
Chen, Deliang ;
Liang, Xinmiao .
CARBOHYDRATE RESEARCH, 2012, 361 :195-199
[8]   Dendrimer-silica hybrid mesoporous materials [J].
El Kadib, Abdelkrim ;
Katir, Nadia ;
Bousmina, Mosto ;
Pierre Majoral, Jean .
NEW JOURNAL OF CHEMISTRY, 2012, 36 (02) :241-255
[9]   A comparison of overload behaviour for some sub 2 μm totally porous and sub 3 μm shell particle columns with ionised solutes [J].
Fallas, Morgane M. ;
Buckenmaier, Stephan M. C. ;
McCalley, David V. .
JOURNAL OF CHROMATOGRAPHY A, 2012, 1235 :49-59
[10]   State-of-the-Art in Immobilized Polymer Stationary Phases for High-Performance Liquid Chromatography [J].
Faria, Anizio M. ;
Collins, Carol H. ;
Jardim, Isabel C. S. F. .
JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2009, 20 (08) :1385-1398