The Stanford Volumetric Modulated Arc Therapy Total Body Irradiation Technique

被引:21
|
作者
Kovalchuk, Nataliya [1 ]
Simiele, Eric [1 ]
Skinner, Lawrie [1 ]
Yang, Yong [1 ]
Howell, Nicole [1 ]
Lewis, Jonathan [1 ]
Hui, Caressa [1 ]
Blomain, Erik [1 ]
Hoppe, Richard T. [1 ]
Hiniker, Susan M. [1 ]
机构
[1] Stanford Univ, Dept Radiat Oncol, Stanford, CA 94305 USA
关键词
BONE-MARROW-TRANSPLANTATION; RADIOTHERAPY; TBI;
D O I
10.1016/j.prro.2021.12.007
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: In this article, we describe the technical aspects of the Stanford volumetric modulated arc therapy (VMAT) total body irradiation (TBI) technique, compare it with other VMAT-TBI techniques, and share our initial experience. Methods and Materials: From September 2019 to August 2021, 35 patients were treated with VMAT-TBI at our institution. Treatment planning was performed using in-house developed automated planning scripts. Organ sparing depended on the regimen: myeloablative (lungs, kidneys, and lenses) and nonmyeloablative with benign disease (lungs, kidneys, lenses, gonads, brain, and thyroid). Quality assurance was performed using electronic portal imaging device portal dosimetry and Mobius3D. Robustness was evaluated for the first 10 patients by performing local and global isocenter shifts of 5 mm. Treatment was delivered using image-guided radiation therapy for every isocenter and every fraction. In vivo measurements were performed on the match line between the VMAT and anteriorposterior/posterior-anterior fields and on the testes for the first fraction. Results: The lungs, lungs - 1 cm, and kidneys D-mean were consistently spared to 57.6% +/- 4.4%, 40.7% +/- 5.5%, and 70.0% +/- 9.9% of the prescription dose, respectively. Gonadal sparing (D-mean = 0.69 +/- 0.13 Gy) was performed for all patients with benign disease. The average planning target volume (PTV) maximum dose to 1 cubic centimeter (D-1c(c)) was 120.7% +/- 6.4% for all patients. The average Gamma passing rate for the VMAT plans was 98.1% +/- 1.6% (criterion of 3%/2 mm). Minimal differences were observed between Mobius3D- and Eclipse AAA-calculated PTV D-mean (0.0% +/- 0.3%) and lungs D-mean (-2.5% +/- 1.2%). Robustness evaluation showed that the PTV D-max and lungs D-mean were insensitive to small positioning deviations between the VMAT isocenters (1.1% +/- 2.4% and 1.2% +/- 1.0%, respectively). The average match-line dose measurement indicated patient setup was reproducible (96.1% +/- 4.5% relative to prescription dose). Treatment time, including patient setup and beam-on, was 47.5 +/- 9.5 min. Conclusions: The Stanford VMAT-TBI technique, from simulation to treatment delivery, was presented and compared with other VMAT-TBI techniques. Together with publicly shared autoplanning scripts, our technique may provide the gateway for wider adaptation of this technology and the possibility of multi-institutional studies in the cooperative group setting. (C) 2022 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:245 / 258
页数:14
相关论文
共 50 条
  • [31] Arc therapy for total body irradiation - A robust novel treatment technique for standard treatment rooms
    Jahnke, Anika
    Jahnke, Lennart
    Molina-Duran, Flavia
    Ehmann, Michael
    Kantz, Steffi
    Steil, Volker
    Wenz, Frederik
    Glatting, Gerhard
    Lohr, Frank
    Polednik, Martin
    RADIOTHERAPY AND ONCOLOGY, 2014, 110 (03) : 553 - 557
  • [32] Evaluation of plan complexity and dosimetric plan quality of total marrow and lymphoid irradiation using volumetric modulated arc therapy
    Lambri, Nicola
    Dei, Damiano
    Hernandez, Victor
    Castiglioni, Isabella
    Clerici, Elena
    De Philippis, Chiara
    Loiacono, Daniele
    Navarria, Pierina
    Reggiori, Giacomo
    Rusconi, Roberto
    Tomatis, Stefano
    Bramanti, Stefania
    Scorsetti, Marta
    Mancosu, Pietro
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2023, 24 (06):
  • [33] Hybrid volumetric modulated arc therapy for whole breast irradiation: a dosimetric comparison of different arc designs
    Ramasubramanian, Velayudham
    Balaji, Karunakaran
    Subramanian, Sitaraman Balaji
    Sathiya, Krishnamoorthi
    Thirunavukarasu, Moorthi
    Radha, Chandrasekaran Anu
    RADIOLOGIA MEDICA, 2019, 124 (06): : 546 - 554
  • [34] Evaluation of volumetric modulated arc therapy technique for cranio-spinal irradiation: A rando - phantom based dosimetric study
    Goksel, E. O.
    Tezcanli, E.
    Okutan, M.
    Bilge, H.
    Yarar, Y. Yildiz
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2021, 19 (03): : 531 - 541
  • [35] Volumetric modulated arc therapy (VMAT) to deliver nodal irradiation in breast cancer patients
    Iorio, Giuseppe Carlo
    Franco, Pierfrancesco
    Gallio, Elena
    Martini, Stefania
    Arcadipane, Francesca
    Bartoncini, Sara
    Rondi, Nadia
    Giglioli, Francesca Romana
    Ala, Ada
    Airoldi, Mario
    Donadio, Michela
    De Sanctis, Corrado
    Castellano, Isabella
    Ricardi, Umberto
    MEDICAL ONCOLOGY, 2018, 35 (01)
  • [36] Volumetric modulated arc therapy for synchronous bilateral whole breast irradiation - A case study
    Seppala, Jan
    Heikkila, Janne
    Myllyoja, Kimmo
    Koskela, Kristiina
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2015, 20 (05) : 398 - 402
  • [37] Treatment planning for volumetric modulated arc therapy
    Bedford, James L.
    MEDICAL PHYSICS, 2009, 36 (11) : 5128 - 5138
  • [38] CLINICAL APPLICATIONS OF VOLUMETRIC MODULATED ARC THERAPY
    Matuszak, Martha M.
    Yan, Di
    Grills, Inga
    Martinez, Alvaro
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 77 (02): : 608 - 616
  • [39] Modulation indices for volumetric modulated arc therapy
    Park, Jong Min
    Park, So-Yeon
    Kim, Hyoungnyoun
    Kim, Jin Ho
    Carlson, Joel
    Ye, Sung-Joon
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (23) : 7315 - 7340
  • [40] Stereotactic body radiation therapy using a respiratory-gated volumetric-modulated arc therapy technique for small hepatocellular carcinoma
    Jeong, Yuri
    Jung, Jinhong
    Cho, Byungchul
    Kwak, Jungwon
    Jeong, Chiyoung
    Kim, Jong Hoon
    Park, Jin-hong
    Kim, So Yeon
    Shim, Ju Hyun
    Kim, Kang Mo
    Lim, Young-Suk
    Lee, Han Chu
    Yoon, Sang Min
    BMC CANCER, 2018, 18