Confinement models of GFRP-confined concrete: Statistical analysis and unified stress-strain models

被引:20
作者
Huang, Liang [1 ]
Gao, Chang [1 ]
Yan, Libo [2 ,3 ]
Kasal, Bohumil [2 ,3 ]
Ma, Gao [1 ]
Tan, Haozhi [1 ]
机构
[1] Hunan Univ, Coll Civil Engn, Changsha 410082, Hunan, Peoples R China
[2] Fraunhofer Wilhelm Klauditz Inst, Ctr Light & Environm Friendly Struct, Braunschweig, Germany
[3] Tech Univ Carolo Wilhelmina Braunschweig, Dept Organ & Wood Based Construct Mat, D-38106 Braunschweig, Germany
关键词
Glass fiber reinforced polymer; confinement model; database; statistical analysis; unified models; FIBER ORIENTATION; JACKETED CONCRETE; BEHAVIOR; COLUMNS; STRENGTH; PERFORMANCE; COMPRESSION; SIZE;
D O I
10.1177/0731684416630609
中图分类号
TB33 [复合材料];
学科分类号
摘要
This paper presented a comprehensive assessment of 22 existing stress models and 13 strain models, which were developed for glass fiber reinforced polymer (GFRP)-confined concrete in uniaxial compression. In addition, a reliability evaluation of these stress and strain models was performed. A database including 212 GFRP-confined cylindrical concrete specimens was collected and analyzed to evaluate the performance of these stress and strain models. The accuracy and applicability assessment of these models were carried out by 2 test and the Pearson correlation coefficient r, and the Monte Carlo-JC method was used by for the reliability assessment. Based on the evaluation, it was found that the unconfined concrete strength fco is the most important parameter which determines the accuracy of these stress and strain models for GFRP-confined concrete. Most stress and strain models used in this study can predict the ultimate axial strength and strain of the GFRP-confined concrete appropriately, although some scattered points exist for some models. In addition, it was found that all these models satisfy the command of reliability even some models are too conservative. Based on the database, unified stress and strain models were proposed showing better applicability.
引用
收藏
页码:867 / 891
页数:25
相关论文
共 68 条
[1]  
ACI, 2002, Committee 440, Rep, Technical Committee Document 440. 2R-02
[2]  
ACI (American Concrete Institute), 2008, Building code requirements for structural concrete (ACI 318M-14) and commentary (ACI 318RM-14)
[3]   BEHAVIOR OF CONCRETE SPIRALLY CONFINED BY FIBERGLASS FILAMENTS [J].
AHMAD, SH ;
KHALOO, AR ;
IRSHAID, A .
MAGAZINE OF CONCRETE RESEARCH, 1991, 43 (156) :143-148
[4]  
Aire C, 2001, COMPOSITES IN CONSTRUCTION, P239
[5]   Behavior of normal and high-strength concrete cylinders confined with E-glass/epoxy composite laminates [J].
Almusallam, Tarek H. .
COMPOSITES PART B-ENGINEERING, 2007, 38 (5-6) :629-639
[6]  
[Anonymous], 2015, IBM SPSS ADV TRAIN C
[7]  
[Anonymous], 2001, GB50068-2001
[8]  
[Anonymous], 2003, THESIS
[9]  
[Anonymous], 2009, P 9 INT S FIB REINF
[10]   Effect of fiber orientation and ply mix on fiber reinforced polymer-confined concrete [J].
Au, C ;
Buyukozturk, O .