Scintillation Efficiency and Position Sensitivity for Radiation Events in Plastic Scintillators

被引:1
作者
Tran, Ngan N. T. [1 ]
Sasaki, Shinichi [2 ]
Sanami, Toshiya [2 ]
Kishimoto, Yuji [2 ]
Shibamura, Eido [3 ]
机构
[1] Grad Univ Adv Studies SOKENDAI, Accelerator Sci Dept, Tsukuba, Ibaraki 3050801, Japan
[2] Grad Univ Adv Studies SOKENDAI, Accelerator Sci Dept, High Energy Accelerator Res Org KEK, Tsukuba, Ibaraki 3050801, Japan
[3] Waseda Univ, Res Inst Sci & Engn, Tokyo 1698555, Japan
关键词
Electron response; light yield; plastic scintillators (PLSs); position sensitivity; CONVERSION EFFICIENCY; CSI(TL) CRYSTALS; PHOTON; REFLECTANCE; NAI(TL); TUBES;
D O I
10.1109/TNS.2018.2805703
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Plastic scintillators (PLSs) are potential materials for the development of a dosimeter based on linear energy transfer (LET) measurement for mixed radiation fields, such as the surroundings of accelerator facilities and in space because PLSs are composed mainly of hydrocarbon molecules, and have the effective atomic number and density similar to those of water and human tissues. In addition, PLSs have a wide range of application in particle physics experiments, owing to their response to all types of radiation (photon, neutron, and charged particles). To use PLSs in designing and constructing an LET spectrometer, essential characteristics of PLSs, such as light yields as a function of deposited energy and radiation species, and the position sensitivity to observe trajectories of incident radiation must be studied. Previously, we performed a procedure for determining the energy deposited in a PLS (EJ-200) for gamma rays from a Cs-137 radiation source using Compton Coincidence Technique. In that measurement, the scintillation efficiency, which was determined as a function of Compton electron energy, approaches a saturation value in the high-energy region and decreases in the low-energy region. The decrease in efficiency possibly suggests the nonproportionality between the light yield and deposited energy. In this paper, the scintillation efficiencies, as well as the absolute light yield of PLSs (EJ-200, EJ-212, and EJ-252) are investigated. In addition, the position sensitivity characteristic is studied by using a PLS rod, and photomultiplier tubes (PMTs) are attached to both ends of the rod, and the position of radiation incidence in the rod can be evaluated by using signals from the PMTs.
引用
收藏
页码:2178 / 2183
页数:6
相关论文
共 12 条
  • [1] Birks J. B., 1967, THEORY PRACTICE SCIN, P185
  • [2] Maximum scintillation yields in NaI(Tl) and CsI(Tl) crystals estimated from the scintillation model for liquid rare gases
    Doke, Tadayoshi
    Shibamura, Eido
    Kubota, Shinzo
    Terasawa, Kazuhiro
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2008, 266 (23) : 5063 - 5066
  • [3] Knoll G.F., 2010, Radiation Detection and Measurement, Vfourth, P229
  • [4] Nonproportionality of electron response using CCT: Plastic scintillator
    Limkitjaroenporrn, P.
    Kaewkhao, J.
    Limsuwan, P.
    Chewpraditkul, W.
    [J]. APPLIED RADIATION AND ISOTOPES, 2010, 68 (09) : 1780 - 1784
  • [5] NELSON WR, 1985, SLAC265 STANF U
  • [6] Benchmarking the compton coincidence technique for measuring electron response non-proportionality in inorganic scintillators
    Rooney, BD
    Valentine, JD
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (03) : 1271 - 1276
  • [7] Average energies required per scintillation photon and energy resolutions in NaI(Tl) and CsI(Tl) crystals for gamma rays
    Sasaki, Shinichi
    Tawara, Hiroko
    Saito, Kiwanm
    Miyajima, Mitsuhiro
    Shibamura, Eido
    [J]. JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 2006, 45 (8A): : 6420 - 6430
  • [8] Photon-to-electron conversion efficiency and reflectance of photornultiplier tubes as a function of incidence angle of photon
    Shibamura, Eido
    Sasaki, Shinichi
    Tawara, Hiroko
    Saito, Kiwamu
    Miyajima, Mitsuhiro
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 567 (01) : 192 - 195
  • [9] Angular response of photomultiplier tubes: Photon-to-electrou conversion efficiency and reflectance
    Shibamura, Eido
    Sasaki, Shinichi
    Tawara, Hiroko
    Saito, Kiwamu
    Miyajima, Mitsuhiro
    [J]. JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 2006, 45 (07): : 5990 - 5995
  • [10] TEMPERATURE-DEPENDENCE OF CSI(T1) ABSOLUTE SCINTILLATION YIELD
    VALENTINE, JD
    WEHE, DK
    KNOLL, GF
    MOSS, CE
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1993, 40 (04) : 1267 - 1274