Theoretical study of space focusing in linear time-of-flight mass spectrometers

被引:19
|
作者
Seccombe, DP [1 ]
Reddish, TJ [1 ]
机构
[1] Univ Newcastle Upon Tyne, Dept Phys, Newcastle Upon Tyne NE1 7RU, Tyne & Wear, England
关键词
D O I
10.1063/1.1336824
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In response to continued improvements in the production of "cold" atoms, molecular beams, and in electronic timing resolution, the issue of space focusing in linear time-of-flight (TOF) mass spectrometers is reevaluated. Starting with the Wiley-McLaren [W. C. Wiley and I. H. McLaren, Rev. Sci. Instrum. 26, 1150 (1955)] condition for first-order space focusing in the conventional two-field system, we extend the approach to higher orders in more complicated situations. A general, solvable, set of equations for satisfying n-order space focusing in an m-field regime is derived. We demonstrate quantitatively that if higher orders of space focus are employed, then provided the initial velocity distribution of the ions is sufficiently narrow, a significant improvement in the mass resolution can be achieved. The conclusions drawn have important implications for the design of the next generation of TOF instruments. (C) 2001 American Institute of Physics.
引用
收藏
页码:1330 / 1338
页数:9
相关论文
共 50 条
  • [31] High Energy Collisions on Tandem Time-of-Flight Mass Spectrometers
    Cotter, Robert J.
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2013, 24 (05) : 657 - 674
  • [32] SECONDARY ION TIME-OF-FLIGHT MASS SPECTROMETERS AND DATA SYSTEMS
    STANDING, KG
    BEAVIS, R
    BOLBACH, G
    ENS, W
    LAFORTUNE, F
    MAIN, D
    SCHUELER, B
    TANG, X
    WESTMORE, JB
    ANALYTICAL INSTRUMENTATION, 1987, 16 (01): : 173 - 189
  • [33] Miniature time-of-flight mass spectrometers for in situ composition studies
    Brinckerhoff, WB
    Cornish, TJ
    McEntire, RW
    Cheng, AF
    Benson, RC
    ACTA ASTRONAUTICA, 2003, 52 (2-6) : 397 - 404
  • [34] Multipass time-of-flight mass spectrometers with high resolving powers
    Casares, A
    Kholomeev, A
    Wollnik, H
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2001, 206 (03) : 267 - 273
  • [35] ION OPTICS FOR TIME-OF-FLIGHT MASS SPECTROMETERS WITH MULTIPLE SYMMETRY
    SAKURAI, T
    MATSUO, T
    MATSUDA, H
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1985, 63 (2-3): : 273 - 287
  • [36] Hybrid quadrupole/time-of-flight mass spectrometers for analysis of biomolecules
    Ens, W
    Standing, KG
    BIOLOGICAL MASS SPECTROMETRY, 2005, 402 : 49 - 78
  • [37] Direct sampling time-of-flight mass spectrometers for technological analysis
    Sysoev, AA
    Sysoev, AA
    Poteshin, SS
    Pyatakhin, VI
    Shchekina, IV
    Trofimov, AS
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1998, 361 (03): : 261 - 266
  • [38] Invited Article: Characterization of background sources in space-based time-of-flight mass spectrometers
    Gilbert, J. A.
    Gershman, D. J.
    Gloeckler, G.
    Lundgren, R. A.
    Zurbuchen, T. H.
    Orlando, T. M.
    McLain, J.
    von Steiger, R.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (09)
  • [39] ON TIME FOCUSING AND PHASE-SPACE DYNAMICS IN TIME-OF-FLIGHT MASS-SPECTROMETER DESIGN
    STEIN, R
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1994, 132 (1-2): : 29 - 47
  • [40] Ideal space focusing in a time-of-flight mass spectrometer: an optimization using an analytical approach
    Doroshenko, VM
    EUROPEAN JOURNAL OF MASS SPECTROMETRY, 2000, 6 (06) : 491 - 499