An experimental study on the wind pressure distribution of tapered super high-rise buildings

被引:16
|
作者
Deng, T. [1 ]
Fu, J. Y. [1 ]
Xie, Z. N. [2 ]
Pi, Y. L. [1 ,3 ]
Shi, B. Q. [2 ]
机构
[1] Guangzhou Univ, Guangzhou Univ Tamkang Univ Joint Res Ctr Engn St, Guangzhou 510006, Guangdong, Peoples R China
[2] South China Univ Technol, Sch Civil Engn & Transportat, State Key Lab Subtrop Bldg Sci, Guangzhou 510640, Guangdong, Peoples R China
[3] UNSW Sydney, Ctr Infrastruct Engn & Safety, Sydney, NSW 2052, Australia
来源
基金
中国国家自然科学基金;
关键词
aerodynamic strategies; peak wind pressure coefficient; super tall building; wind force coefficient; wind tunnel test; AERODYNAMIC FORCES; RESPONSES; SHAPES; LOADS;
D O I
10.1002/tal.1483
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Studies on the effect of different shape strategies on wind-induced responses of super tall buildings have been extensive. However, little systematic research on the influence of aerodynamic shapes on wind pressure distributions of super high-rise building having a height more than 500m is reported in the literature. In this paper, a series of wind tunnel tests are conducted on models simulating tapered buildings taller than 500m with an aspect ratio of 9:1 by applying synchronous pressure measurement technology to investigate the influence of different shape strategies on the wind force coefficients of the cross section (C-s) and on the peak negative pressure distributions on surfaces. The shape strategies considered include tapering of the cross section of a building along its height, chamfered modification, and opening ventilation slots. It is found that the wind force coefficient C-s increase with an increase of the tapering ratio. It is shown that chamfered modification can effectively reduce most of the wind force coefficients C-s to less than 0.9. As for peak wind pressures, a zone having a higher negative pressure is found to locate at the bottom of the side faces of the model. With an increase of the tapering ratio, the peak negative pressure of side faces of the model slightly decreases. Chamfered modification can significantly increase the peak negative pressure at the chamfered location. Furthermore, it is demonstrated that opening ventilation slots had less effect on C-s, but the peak negative pressure can significantly increase at the area of opening ventilation slots and adjacent areas.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Study on surface wind pressure and pedestrian wind environment of super high-rise buildings
    Zheng X.-N.
    Cui H.-M.
    Liu Q.-K.
    Gongcheng Lixue/Engineering Mechanics, 2021, 38 : 223 - 227
  • [2] Aerodynamic measurements of across-wind loads and responses of tapered super high-rise buildings
    Deng, Ting
    Yu, Xianfeng
    Xie, Zhuangning
    WIND AND STRUCTURES, 2015, 21 (03) : 331 - 352
  • [3] Acoustic wind tunnel experimental study of aerodynamic noise distribution in high-rise buildings
    Li, Jia 'nan
    Li, Zhengnong
    JOURNAL OF BUILDING ENGINEERING, 2024, 91
  • [4] Wind force of super high-rise buildings with hexagonal section
    Wang, Lei
    Zhang, Wei
    Liu, Li-sheng
    Zhang, Zheng-hua
    STRUCTURES, 2021, 33 : 283 - 291
  • [5] Interference effects on wind pressure distribution between two high-rise buildings
    Yu, X. F.
    Xie, Z. N.
    Zhu, J. B.
    Gu, M.
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2015, 142 : 188 - 197
  • [6] Study on the influence of appendages on local wind pressure of high-rise buildings
    Yuan K.
    Zhang X.
    Hui Y.
    Chen Z.
    Zhendong yu Chongji/Journal of Vibration and Shock, 2020, 39 (07): : 202 - 208
  • [7] Experimental study on wind load characteristics of high-rise buildings with opening
    Li, Yong-Gui
    Zhang, Ming-Yue
    Li, Yi
    Li, Qiu-Sheng
    Liu, Si-Jia
    STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2020, 29 (09):
  • [8] Experimental research on wind tunel pressure measurement of a super high-rise building
    Shao Y.-H.
    Cui H.-M.
    Liu Q.-K.
    Zheng Y.-F.
    Gongcheng Lixue/Engineering Mechanics, 2021, 38 : 26 - 30and38
  • [9] Wind tunnel test study on the wind pressure coefficient of claddings of high-rise buildings
    Quan Y.
    Liang Y.
    Wang F.
    Gu M.
    Frontiers of Architecture and Civil Engineering in China, 2011, 5 (4): : 518 - 524
  • [10] Experimental Study on the Influence of Planar Configuration on Wind Load Distribution Characteristics of High-Rise Buildings with Whole Wind Azimuths
    Chen, Qiuhua
    Zhang, Xiaoxi
    ENERGIES, 2024, 17 (15)