The wastewater disinfection system of UV lamps based on can bus

被引:0
作者
Wang, Song [1 ]
Liu, Mingguang
Hao, Shengyu
Li, Na
机构
[1] Beijing Jiaotong Univ, Beijing 100010, Peoples R China
[2] Shandong Univ, Jinan 100044, Peoples R China
来源
2007 International Symposium on Computer Science & Technology, Proceedings | 2007年
关键词
wastewater treatment; UV disinfection; fuzzy control; CAN bus;
D O I
暂无
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Based on the current situation and development of urban wastewater treatment, this paper introduces the advantages of the ultraviolet disinfection, the concept of field-bus and application of CAN bus control system in the field of municipal wastewater by using UV disinfection lamps in detail. Furthermore, the paper also gives the design of the system's network structure, hardware configuration and working principles. The system uses ARM9 as the control core of the hardware, and the fuzzy control arithmetic is used for the control of UV lamps. The practices have proved effectiveness and validity of the system.
引用
收藏
页码:548 / 551
页数:4
相关论文
共 50 条
  • [21] Geometry Defeaturing Effects in CFD Model-Based Assessment of an Open-Channel-Type UV Wastewater Disinfection System
    Bak, Jeong-Gyu
    Hwang, Woochul
    Cho, Jinsoo
    WATER, 2017, 9 (09)
  • [22] Ozone and UV254 Radiation for Municipal Wastewater Disinfection
    Blatchley, Ernest R., III
    Weng, ShihChi
    Afifi, Mehrnaz Zare
    Chiu, Hsiao-Han
    Reichlin, Douglas B.
    Jousset, Stephane
    Erhardt, Richard S.
    WATER ENVIRONMENT RESEARCH, 2012, 84 (11) : 2017 - 2027
  • [23] Electrostatic Precipitator Monitoring System Based on CAN Bus
    Zhang, Zi-sheng
    Hao, Qing
    Cui, Chao
    Lian, Ya-fei
    Xiao, Zhen-lei
    Liu, Zhi-qiang
    Li, Qing
    2010 INTERNATIONAL COLLOQUIUM ON COMPUTING, COMMUNICATION, CONTROL, AND MANAGEMENT (CCCM2010), VOL IV, 2010, : 121 - 123
  • [24] A Auto Safety Monitoring System Based on CAN Bus
    Su, Weijia
    He, Yongning
    2010 INTERNATIONAL CONFERENCE ON INFORMATION, ELECTRONIC AND COMPUTER SCIENCE, VOLS 1-3, 2010, : 1760 - 1763
  • [25] Monitoring system of CAN bus based on OPC technology
    Qin, Song Yu
    Li, Li Chun
    NANOTECHNOLOGY AND PRECISION ENGINEERING, PTS 1 AND 2, 2013, 662 : 713 - 716
  • [26] Faecal bacteria and bacteriophage inactivation in a full-scale UV disinfection system used for wastewater reclamation
    Bourrouet, A
    García, J
    Mujeriego, R
    Peñuelas, G
    WATER SCIENCE AND TECHNOLOGY, 2001, 43 (10) : 187 - 194
  • [27] Application of UV disinfection in municipal wastewater treatment plants for agricultural use of reclaimed wastewater in Turkey
    Evcimen, Serkan
    Kerc, Aslihan
    DESALINATION AND WATER TREATMENT, 2011, 26 (1-3) : 39 - 44
  • [28] Design and Realization of Fire Alarm System Based on CAN Bus
    Chen Yneping
    Gan Fangcheng
    Zhang Yongxian
    ICEMI 2007: PROCEEDINGS OF 2007 8TH INTERNATIONAL CONFERENCE ON ELECTRONIC MEASUREMENT & INSTRUMENTS, VOL I, 2007, : 832 - 836
  • [29] AMT Fault Information System Based on CAN Bus Gateway
    Liu Xianqiang
    Liu Haiou
    PROCEEDINGS OF THE 2014 INTERNATIONAL CONFERENCE ON MECHATRONICS, CONTROL AND ELECTRONIC ENGINEERING, 2014, 113 : 11 - 15
  • [30] Research and Design of Vehicle Control System Based on CAN Bus
    Wang Siyang
    Qi Ying Jie
    AGRO FOOD INDUSTRY HI-TECH, 2017, 28 (01): : 1024 - 1028