Percutaneous renal biopsy: Comparison of blind and real-time ultrasound-guided technique

被引:65
作者
Maya, Ivan D.
Maddela, Prathyusha
Barker, Jill
Allon, Michael
机构
[1] Div Nephrol, Birmingham, AL 35294 USA
[2] Univ Alabama, Div Nephrol, Birmingham, AL USA
[3] Montana State Univ, Dept Microbiol, Bozeman, MT 59717 USA
关键词
D O I
10.1111/j.1525-139X.2007.00295.x
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
The use of real-time ultrasound-guided renal biopsy is believed to be superior to blind biopsy, but there are few reports comparing the two techniques. The goal of the present study was to compare the outcomes of ultrasound-guided and blind renal biopsies at a single teaching institution, in terms of adequacy of tissue yield and frequency of hemorrhagic complications. We reviewed retrospectively the outcomes of all patients undergoing a percutaneous native kidney biopsy during a 2-year period (January 1, 2004 to December 31, 2005). Of 129 renal biopsies, 65 were ultrasound-guided and 64 were performed by the blind technique. All biopsies were performed by nephrology fellows under direct faculty supervision. The two patient groups were comparable in terms of age, sex, race, diabetes, hypertension, serum creatinine, and hematocrit. The mean number of glomeruli per biopsy was higher in the ultrasound-guided group than in the patients with a blind biopsy (18 9 versus 11 9, p = 0.0001). An inadequate tissue sample requiring repeat biopsy occurred in 0% of the ultrasound-guided biopsies and 16% of the blind biopsies (p = 0.0006). Large hematomas requiring vascular intervention or transfusion were less frequent in the ultrasound-guided biopsies (0% versus 11%, p = 0.006). The hematocrit 24 hours postbiopsy was higher in the ultrasound-guided biopsies when compared with the blind biopsies (32 +/- 5% versus 30 +/- 4%, p = 0.04). When compared with blind renal biopsy, real-time ultrasound-guided percutaneous renal biopsy provides a superior yield of kidney tissue and results in fewer hemorrhagic complications. Realtime ultrasound-guided renal biopsy is the preferred technique.
引用
收藏
页码:355 / 358
页数:4
相关论文
共 12 条
[1]   THE USE OF THE AUTOMATIC CORE BIOPSY SYSTEM IN PERCUTANEOUS RENAL BIOPSIES - A COMPARATIVE-STUDY [J].
BURSTEIN, DM ;
KORBET, SM ;
SCHWARTZ, MM .
AMERICAN JOURNAL OF KIDNEY DISEASES, 1993, 22 (04) :545-552
[2]   CONVENTIONAL 15G NEEDLE TECHNIQUE FOR RENAL BIOPSY COMPARED WITH ULTRASOUND-GUIDED SPRING-LOADED 18G NEEDLE-BIOPSY [J].
COZENS, NJA ;
MURCHISON, JT ;
ALLAN, PL ;
WINNEY, RJ .
BRITISH JOURNAL OF RADIOLOGY, 1992, 65 (775) :594-597
[3]   EXPERIENCE WITH A NEW METHOD FOR PERCUTANEOUS RENAL BIOPSY [J].
DONOVAN, KL ;
THOMAS, DM ;
WHEELER, DC ;
MACDOUGALL, IC ;
WILLIAMS, JD .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 1991, 6 (10) :731-733
[4]   ULTRASOUND GUIDED PERCUTANEOUS RENAL BIOPSY USING AN AUTOMATIC CORE BIOPSY SYSTEM [J].
DOWD, PE ;
MATA, JA ;
CROW, A ;
CULKIN, DJ ;
VENABLE, DD .
JOURNAL OF UROLOGY, 1991, 146 (05) :1216-1217
[5]   PERCUTANEOUS NATIVE RENAL BIOPSY - COMPARISON OF A 1.2-MM SPRING-DRIVEN SYSTEM WITH A TRADITIONAL 2-MM HAND-DRIVEN SYSTEM [J].
DOYLE, AJ ;
GREGORY, MC ;
TERREROS, DA .
AMERICAN JOURNAL OF KIDNEY DISEASES, 1994, 23 (04) :498-503
[6]   Safety of ultrasound-guided percutaneous renal biopsy - retrospective analysis of 1090 consecutive cases [J].
Hergesell, O ;
Felten, H ;
Andrassy, K ;
Kuhn, K ;
Ritz, E .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 1998, 13 (04) :975-977
[7]   A randomized, prospective, comparative study of manual and automated renal biopsies [J].
Kim, D ;
Kim, H ;
Shin, G ;
Ku, S ;
Ma, KG ;
Shin, S ;
Gi, H ;
Lee, E ;
Yim, H .
AMERICAN JOURNAL OF KIDNEY DISEASES, 1998, 32 (03) :426-431
[8]   Timing of complications in percutaneous renal biopsy: What is the optimal period of observation? [J].
Marwah, DS ;
Korbet, SM .
AMERICAN JOURNAL OF KIDNEY DISEASES, 1996, 28 (01) :47-52
[9]   Bedside renal biopsy: Ultrasound guidance by the nephrologist [J].
Nass, K ;
O'Neill, WC .
AMERICAN JOURNAL OF KIDNEY DISEASES, 1999, 34 (05) :955-959
[10]  
Nyman RS, 1997, ACTA RADIOL, V38, P431