Reliable Operation of the Brookhaven EBIS for Highly Charged Ion Production for RHIC and NSRL

被引:18
作者
Beebe, E. [1 ]
Alessi, J. [1 ]
Binello, S. [1 ]
Kanesue, T. [1 ]
McCafferty, D. [1 ]
Morris, J. [1 ]
Okamura, M. [1 ]
Pikin, A. [1 ]
Ritter, J. [1 ]
Schoepfer, R. [1 ]
机构
[1] Brookhaven Natl Lab, Upton, NY 11973 USA
来源
PROCEEDINGS OF THE XII INTERNATIONAL SYMPOSIUM ON ELECTRON BEAM ION SOURCES AND TRAPS | 2015年 / 1640卷
关键词
ELECTRON-BEAM;
D O I
10.1063/1.4905394
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
An Electron Beam Ion Source for the Relativistic Heavy Ion Collider (RHIC EBIS) was commissioned at Brookhaven in September 2010 and since then it routinely supplies ions for RHIC and NASA Space Radiation Laboratory (NSRL) as the main source of highly charged ions from Helium to Uranium. Using three external primary ion sources for 1+ injection into the EBIS and an electrostatic injection beam line, ion species at the EBIS exit can be switched in 0.2 s. A total of 16 different ion species have been produced to date. The length and the capacity of the ion trap have been increased by 20% by extending the trap by two more drift tubes, compared with the original design. The fraction of Au32+ in the EBIS Au spectrum is approximately 12% for 70-80% electron beam neutralization and 8 pulses operation in a 5 Hertz train and 4-5 s super cycle. For single pulse per super cycle operation and 25% electron beam neutralization, the EBIS achieves the theoretical Au32+ fractional output of 18%. Long term stability has been very good with availability of the beam from RHIC EBIS during 2012 and 2014 RHIC runs approximately 99.8%.
引用
收藏
页数:7
相关论文
共 9 条
  • [1] The Brookhaven National Laboratory electron beam ion source for RHIC
    Alessi, J. G.
    Barton, D.
    Beebe, E.
    Bellavia, S.
    Gould, O.
    Kponou, A.
    Lambiase, R.
    Lockey, R.
    McNerney, A.
    Mapes, M.
    Marneris, Y.
    Okamura, M.
    Phillips, D.
    Pikin, A. I.
    Raparia, D.
    Ritter, J.
    Snydstrup, L.
    Theisen, C.
    Wilinski, M.
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2010, 81 (02)
  • [2] Design of an EBIS for RHIC
    Alessi, JG
    Beebe, E
    Graham, D
    Kponou, A
    Pikin, A
    Prelec, K
    Ritter, J
    Zajic, V
    [J]. PROCEEDINGS OF THE 2003 PARTICLE ACCELERATOR CONFERENCE, VOLS 1-5, 2003, : 89 - 91
  • [3] Extraction of highly charged Au ions from a multiampere electron beam EBIS at BNL
    Beebe, EN
    Alessi, JG
    Gould, O
    Graham, D
    Kponou, A
    Pikin, A
    Prelec, K
    Ritter, J
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2002, 73 (02) : 699 - 701
  • [4] Simulation of 10 A electron-beam formation and collection for a high current electron-beam ion source
    Kponou, A
    Beebe, E
    Pikin, A
    Kuznetsov, G
    Batazova, M
    Tiunov, M
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1998, 69 (02) : 1120 - 1122
  • [5] Experimental study of electron- and ion-beam properties on the BNL electron-beam ion source and comparison with theoretical models
    Pikin, A.
    Alessi, J. G.
    Beebe, E. N.
    Kponou, A.
    Prelec, K.
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2006, 77 (03)
  • [6] RHIC EBIS: basics of design and status of commissioning
    Pikin, A.
    Alessi, J. G.
    Beebe, E. N.
    Kponou, A.
    Lambiase, R.
    Lockey, R.
    Raparia, D.
    Ritter, J.
    Snydstrup, L.
    Tan, Y.
    [J]. JOURNAL OF INSTRUMENTATION, 2010, 5
  • [7] Experimental study of ion injection into an extended trap of the Brookhaven National Laboratory EBIS
    Pikin, A
    Alessi, J
    Beebe, E
    Kponou, A
    Prelec, K
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2002, 73 (02) : 670 - 672
  • [8] Pikin A., 2011, P ICIS 2011, pPM26
  • [9] Pikin A., 2006, 246 BNL CAD CAAP