Comparison of temporary and permanent stent placement with concurrent radiation therapy in patients with esophageal carcinoma

被引:72
作者
Shin, JH
Song, HY
Kim, JH
Kim, SB
Lee, GH
Park, SI
Han, YM
Kang, W
机构
[1] Univ Ulsan, Coll Med, Asan Med Ctr, Dept Radiol, Seoul 138736, South Korea
[2] Univ Ulsan, Coll Med, Asan Med Ctr, Dept Internal Med, Seoul 138736, South Korea
[3] Univ Ulsan, Coll Med, Asan Med Ctr, Dept Thorac & Cardiovasc Surg, Seoul 138736, South Korea
[4] Chonbuk Natl Univ, Coll Med, Dept Radiol, Chonju, South Korea
[5] Taejon Univ, Dept Informat & Stat, Taejon, South Korea
关键词
D O I
10.1097/01.RVI.0000142585.9055.74
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To assess the clinical effectiveness of temporary metallic stent placement with concurrent radiation therapy in patients with esophageal carcinoma by comparing it with permanent stent placement with concurrent radiation therapy. MATERIALS AND METHODS: Covered retrievable expandable nitinol stents were placed in 47 patients with esophageal carcinoma 1 week before starting radiation therapy; the stents were electively removed 4 weeks after placement in 24 patients (group A), while not electively removed in the other 23 patients (group B). In cases of complications, the stents were also removed from patients in groups A and B. The dysphagia score, complications (severe pain, granulation tissue formation, stent migration, esophagorespiratory fistula, and hematemesis), tumor overgrowth/regrowth, reintervention rates, and dysphagia-progression-free and overall survival rates were compared in the two groups. RESULTS: Stent placement or removal was technically successful and well tolerated in all patients. The dysphagia score was significantly improved in both groups after stent placement (P < .01). Each of the stent-related complications was less in group A than in group B but there was no significant difference. However, the total number of patients with one or more than one complications and who needed related reinterventions was significantly less in group A than in group B (P = .042 and .030, respectively). Tumor overgrowth/regrowth and the total number of patients who required related reinterventions was not significantly different (P = 1.00 and .517, respectively). Dysphagia-progression-free and overall survival rates were significantly longer in group A than in group B (P = .005 and .001, respectively). CONCLUSION: Temporary placement of a covered retrievable expandable metallic stent with concurrent radiation therapy for patients with esophageal carcinoma is beneficial for reducing complications and related reinterventions and for increasing resultant survival rates compared with permanent esophageal stent placement.
引用
收藏
页码:67 / 74
页数:8
相关论文
共 24 条
[21]   ESOPHAGOGASTRIC NEOPLASMS - PALLIATION WITH A MODIFIED GIANTURCO STENT [J].
SONG, HY ;
CHOI, KC ;
CHO, BH ;
AHN, DS ;
KIM, KS .
RADIOLOGY, 1991, 180 (02) :349-354
[22]   COVERED, EXPANDABLE ESOPHAGEAL METALLIC STENT TUBES - EXPERIENCES IN 119 PATIENTS [J].
SONG, HY ;
DO, YS ;
HAN, YM ;
SUNG, KB ;
CHOI, EK ;
SOHN, KH ;
KIM, HR ;
KIM, SH ;
MIN, YI .
RADIOLOGY, 1994, 193 (03) :689-695
[23]   Delayed complications after esophageal stent placement for treatment of malignant esophageal obstructions and esophagorespiratory fistulas [J].
Wang, MQ ;
Sze, DY ;
Wang, SP ;
Wang, ZQ ;
Gao, YA ;
Dake, MD .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2001, 12 (04) :465-474
[24]   Curative radiotherapy with high-dose-rate brachytherapy boost for localized esophageal carcinoma: dose-effect relationship of brachytherapy with the balloon type applicator system [J].
Yorozu, A ;
Dokiya, T ;
Oki, Y ;
Suzuki, T .
RADIOTHERAPY AND ONCOLOGY, 1999, 51 (02) :133-139