Magnetisation transfer effects of Q2TIPS pulses in ASL

被引:6
作者
De Vita, Enrico [1 ,2 ]
Guenther, Matthias [3 ,4 ,5 ]
Golay, Xavier [1 ,2 ]
Thomas, David L. [2 ]
机构
[1] Univ Coll London Hosp NHS Fdn Trust, Natl Hosp Neurol & Neurosurg, Lysholm Dept Neuroradiol, London WC1N 3BG, England
[2] UCL Inst Neurol, Dept Brain Repair & Rehabil, Acad Neuroradiol Unit, London WC1N 3BG, England
[3] Mediri GmbH, Heidelberg, Germany
[4] Fraunhofer MEVIS Inst Med Image Comp, Bremen, Germany
[5] Univ Bremen, Fac Phys & Elect Engn, D-28359 Bremen, Germany
关键词
Brain/blood supply; Cerebrovascular circulation/physiology; Humans; Magnetic resonance imaging/methods; Spin labels; CEREBRAL-BLOOD-FLOW; IN-VIVO MEASUREMENT; IMAGING TECHNIQUES; ARTERIAL-BLOOD; HUMAN BRAIN; QUIPSS II; INVERSION; TIME; MRI; QUANTIFICATION;
D O I
10.1007/s10334-011-0298-z
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In pulsed arterial spin labelling (ASL), Q2TIPS saturation pulses are used to actively control the temporal width of the labelled bolus. However, these Q2TIPS pulses also induce magnetisation transfer (MT) effects in the adjacent tissue. In this work, we investigated how Q2TIPS-related MT alters tissue signal in pulsed ASL and, consequently, CBF quantification. Seven volunteers were studied at 3 tesla using a multi-TI FAIR sequence and 3D-GRASE readout with background suppression. Q2TIPS pulses were used and the spacing between RF pulses was varied to modulate MT effects. Computer simulations were designed to mimic in-vivo signals at multiple TI values. Q2TIPS-associated MT was found to reduce tissue T1 and M0 values by up to 42 and 50% respectively; leading to a reduction of up to 40% in the effectiveness of background suppression and, therefore, increased sensitivity to motion for the longest TI values. In addition, greater MT effects were associated with reduced grey matter CBF estimates of up to 15%. The MT effect associated with the Q2TIPS pulse train has a significant effect on tissue signal. It is recommended that MT effects are characterised and both background suppression and Q2TIPS schemes are accordingly optimised to reduce the effects of MT on accuracy and precision of CBF estimation.
引用
收藏
页码:113 / 126
页数:14
相关论文
共 28 条
[1]   A general kinetic model for quantitative perfusion imaging with arterial spin labeling [J].
Buxton, RB ;
Frank, LR ;
Wong, EC ;
Siewert, B ;
Warach, S ;
Edelman, RR .
MAGNETIC RESONANCE IN MEDICINE, 1998, 40 (03) :383-396
[2]   Variational Bayesian Inference for a Nonlinear Forward Model [J].
Chappell, Michael A. ;
Groves, Adrian R. ;
Whitcher, Brandon ;
Woolrich, Mark W. .
IEEE TRANSACTIONS ON SIGNAL PROCESSING, 2009, 57 (01) :223-236
[3]   Variation in the Shape of Pulsed Arterial Spin Labeling Kinetic Curves across the Healthy Human Brain and Its Implications for CBF Quantification [J].
Gallichan, Daniel ;
Jezzard, Peter .
MAGNETIC RESONANCE IN MEDICINE, 2009, 61 (03) :686-695
[4]   Pulsed star labeling of arterial regions (PULSAR): A robust regional perfusion technique for high field imaging [J].
Golay, X ;
Petersen, ET ;
Hui, F .
MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (01) :15-21
[5]  
Golay Xavier, 2004, Top Magn Reson Imaging, V15, P10, DOI 10.1097/00002142-200402000-00003
[6]   Generalized Autocalibrating Partially Parallel Acquisitions (GRAPPA) [J].
Griswold, MA ;
Jakob, PM ;
Heidemann, RM ;
Nittka, M ;
Jellus, V ;
Wang, JM ;
Kiefer, B ;
Haase, A .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (06) :1202-1210
[7]   Single-shot 3D imaging techniques improve arterial spin labeling perfusion measurements [J].
Günther, M ;
Oshio, K ;
Feinberg, DA .
MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (02) :491-498
[8]   Arterial spin labeling in combination with a look-locker sampling strategy:: Inflow turbo-sampling EPI-FAIR (ITS-FAIR) [J].
Günther, M ;
Bock, M ;
Schad, LR .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (05) :974-984
[9]   Magnetization transfer effects on the efficiency of flow-driven adiabatic fast passage inversion of arterial blood [J].
Hernandez-Garcia, Luis ;
Lewis, David P. ;
Moffat, Bradford ;
Branch, Craig A. .
NMR IN BIOMEDICINE, 2007, 20 (08) :733-742
[10]   QUANTIFICATION OF RELATIVE CEREBRAL BLOOD-FLOW CHANGE BY FLOW-SENSITIVE ALTERNATING INVERSION-RECOVERY (FAIR) TECHNIQUE - APPLICATION TO FUNCTIONAL MAPPING [J].
KIM, SG .
MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (03) :293-301