Use of Artificial Intelligence to Reduce Radiation Exposure at Fluoroscopy-Guided Endoscopic Procedures

被引:36
作者
Bang, Ji Young [1 ]
Hough, Matthew [2 ]
Hawes, Robert H. [1 ]
Varadarajulu, Shyam [1 ]
机构
[1] AdventHealth, Ctr Intervent Endoscopy, Orlando, FL 32803 USA
[2] AdventHealth, Dept Radiat Safety & Med Phys, Orlando, FL USA
关键词
PROTECTION; STAFF; ERCP; TIME;
D O I
10.14309/ajg.0000000000000565
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
OBJECTIVES: Exposure to ionizing radiation remains a hazard for patients and healthcare providers. We evaluated the utility of an artificial intelligence (AI)-enabled fluoroscopy system to minimize radiation exposure during image-guided endoscopic procedures. METHODS: We conducted a prospective study of 100 consecutive patients who underwent fluoroscopy-guided endoscopic procedures. Patients underwent interventions using either conventional or AI-equipped fluoroscopy system that uses ultrafast collimation to limit radiation exposure to the region of interest. The main outcome measure was to compare radiation exposure with patients, which was measured by dose area product. Secondary outcome was radiation scatter to endoscopy personnel measured using dosimeter. RESULTS: Of 100 patients who underwent procedures using traditional (n = 50) or AI-enabled (n = 50) fluoroscopy systems, there was no significant difference in demographics, body mass index, procedural type, and procedural or fluoroscopy time between the conventional and the AI-enabled fluoroscopy systems. Radiation exposure to patients was lower (median dose area product 2,178 vs 5,708 mGym(2),P= 0.001) and scatter effect to endoscopy personnel was less (total deep dose equivalent 0.28 vs 0.69 mSv; difference of 59.4%) for AI-enabled fluoroscopy as compared to conventional system. On multivariate linear regression analysis, after adjusting for patient characteristics, procedural/fluoroscopy duration, and type of fluoroscopy system, only AI-equipped fluoroscopy system (coefficient 3,331.9 [95% confidence interval: 1,926.8-4,737.1,P< 0.001) and fluoroscopy duration (coefficient 813.2 [95% confidence interval: 640.5-985.9],P< 0.001) were associated with radiation exposure. DISCUSSION: The AI-enabled fluoroscopy system significantly reduces radiation exposure to patients and scatter effect to endoscopy personnel (see Graphical abstract, Supplementary Digital Content, http://links. lww.com/AJG/B461).
引用
收藏
页码:555 / 561
页数:7
相关论文
共 35 条
  • [21] Radiation doses to patients during ERCP
    Larkin, CJ
    Workman, A
    Wright, RER
    Tham, TCK
    [J]. GASTROINTESTINAL ENDOSCOPY, 2001, 53 (02) : 161 - 164
  • [22] Cancer risks associated with external radiation from diagnostic imaging procedures
    Linet, Martha S.
    Slovis, Thomas L.
    Miller, Donald L.
    Kleinerman, Ruth
    Lee, Choonsik
    Rajaraman, Preetha
    de Gonzalez, Amy Berrington
    [J]. CA-A CANCER JOURNAL FOR CLINICIANS, 2012, 62 (02) : 75 - 100
  • [23] Ocular radiation exposure during endoscopic retrograde cholangiopancreatography: a meta-analysis of studies
    Menon, Shyam
    Mathew, Ray
    Kumar, Mayur
    [J]. EUROPEAN JOURNAL OF GASTROENTEROLOGY & HEPATOLOGY, 2019, 31 (04) : 463 - 470
  • [24] A Double-Blind, Randomized, Sham-Controlled Trial of the Effect of a Radiation-Attenuating Drape on Radiation Exposure to Endoscopy Staff During ERCP
    Muniraj, Thiruvengadam
    Aslanian, Harry R.
    Laine, Loren
    Farrell, James
    Ciarleglio, Maria M.
    Deng, Yanhong
    Ho, Henry
    Jamidar, Priya A.
    [J]. AMERICAN JOURNAL OF GASTROENTEROLOGY, 2015, 110 (05) : 690 - 696
  • [25] Minimizing occupational hazards in endoscopy: personal protective equipment, radiation safety, and ergonomics
    Pedrosa, Marcos C.
    Farraye, Francis A.
    Shergill, Amandeep K.
    Banerjee, Subhas
    Desilets, David
    Diehl, David L.
    Kaul, Vivek
    Kwon, Richard S.
    Mamula, Petar
    Rodriguez, Sarah A.
    Varadarajulu, Shyam
    Song, Louis-Michel Wong Kee
    Tierney, William M.
    [J]. GASTROINTESTINAL ENDOSCOPY, 2010, 72 (02) : 227 - 235
  • [26] Petoussi-Henss N, 2010, Ann ICRP, V40, P1, DOI 10.1016/j.icrp.2011.10.001
  • [27] RADIATION AND CATARACT
    Rehani, Madan M.
    Vano, Eliseo
    Ciraj-Bjelac, Olivera
    Kleiman, Norman J.
    [J]. RADIATION PROTECTION DOSIMETRY, 2011, 147 (1-2) : 300 - 304
  • [28] Risk of cancer from occupational exposure to ionising radiation: retrospective cohort study of workers in France, the United Kingdom, and the United States (INWORKS)
    Richardson, David B.
    Cardis, Elisabeth
    Daniels, Robert D.
    Gillies, Michael
    O'Hagan, Jacqueline A.
    Hamra, Ghassan B.
    Haylock, Richard
    Laurier, Dominique
    Leuraud, Klervi
    Moissonnier, Monika
    Schubauer-Berigan, Mary K.
    Thierry-Chef, Isabelle
    Kesminiene, Ausrele
    [J]. BMJ-BRITISH MEDICAL JOURNAL, 2015, 351
  • [29] Radiation Training, Radiation Protection, and Fluoroscopy Utilization Practices Among US Therapeutic Endoscopists
    Sethi, Saurabh
    Barakat, Monique T.
    Friedland, Shai
    Banerjee, Subhas
    [J]. DIGESTIVE DISEASES AND SCIENCES, 2019, 64 (09) : 2455 - 2466
  • [30] Sharma SS, 2008, J GASTROINTEST LIVER, V17, P183