Transcatheter utilisation of lifetech multifunction™ occluder device for closure of perimembranous and muscular ventricular septal defects: first use in North America

被引:5
作者
Bjorkman, Kurt R. [1 ]
Aldoss, Osamah [1 ]
Maldonado, Jennifer R. [1 ]
McLennan, Daniel [1 ]
机构
[1] Univ Iowa, Stead Family Childrens Hosp, Div Pediat Cardiol, Dept Pediat, 200 Hawkins Dr BT1010, Iowa City, IA 52242 USA
关键词
Heart defects; congenital; cardiac catheter;
D O I
10.1017/S1047951121001050
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Transcatheter closure of ventricular septal defects is considered first-line therapy when anatomically appropriate but is often challenged by proximity to the conduction system in perimembranous defects, or irregular defect shape, especially residual defects that may remain post-operatively. Advancements in device design, however, have allowed for significant improvements in deployment techniques and overall safety. Here we describe the first use of the Lifetech Konar-multifunction (TM) occluder device in North America, and our specific use of this device to close complex post-operative muscular and a perimembranous-ventricular septal defects in the same patient.
引用
收藏
页码:1525 / 1527
页数:3
相关论文
共 6 条
[1]   Successful percutaneous occlusion of a large left circumflex coronary artery fistula draining into the coronary sinus using a ventricular septal defect occluder: a case report [J].
Egorova, Anastasia D. ;
Ewert, Peter ;
Hadamitzky, Martin ;
Eicken, Andreas .
EUROPEAN HEART JOURNAL-CASE REPORTS, 2020, 4 (02)
[2]   Percutaneous closure of restrictive-type perimembranous ventricular septal defect using the new KONAR multifunctional occluder: Midterm outcomes of the first middle-eastern experience [J].
Haddad, Raymond N. ;
Daou, Linda S. ;
Saliba, Zakhia S. .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2020, 96 (03) :E295-E302
[3]   First European experience of percutaneous closure of ventricular septal defects using a new CE-marked VSD occluder [J].
Schubert, Stephan ;
Kelm, Marcus ;
Koneti, Nageswara Rao ;
Berger, Felix .
EUROINTERVENTION, 2019, 15 (03) :E242-E243
[4]   Use of Lifetech™ Konar-MF, a device for both perimembranous and muscular ventricular septal defects: A multicentre study [J].
Tanidir, Ibrahim Cansaran ;
Baspinar, Osman ;
Saygi, Murat ;
Kervancioglu, Mehmet ;
Guzeltas, Alper ;
Odemis, Ender .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2020, 310 :43-50
[6]   ACC/AHA 2008 Guidelines for the Management of Adults With Congenital Heart Disease [J].
Warnes, Carole A. ;
Williams, Roberta G. ;
Bashore, Thomas M. ;
Child, John S. ;
Connolly, Heidi M. ;
Dearani, Joseph A. ;
del Nido, Pedro ;
Fasules, James W. ;
Graham, Thomas P., Jr. ;
Hijazi, Ziyad M. ;
Hunt, Sharon A. ;
King, Mary Etta ;
Landzberg, Michael J. ;
Miner, Pamela D. ;
Radford, Martha J. ;
Walsh, Edward P. ;
Webb, Gary D. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 52 (23) :E1-E121