In vitro and in vivo evaluation of electromagnetic interference between wireless home monitoring pacemakers and GSM mobile phones

被引:2
作者
Barbaro, V [1 ]
Bartolini, P [1 ]
Calcagnini, G [1 ]
Censi, F [1 ]
Floris, M [1 ]
Pignalberi, C [1 ]
Ricci, R [1 ]
Santini, M [1 ]
机构
[1] Ist Super Sanita, Biomed Engn Lab, Rome, Italy
来源
PROCEEDINGS OF THE 25TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: A NEW BEGINNING FOR HUMAN HEALTH | 2003年 / 25卷
关键词
electromagnetic compatibility; home monitoring; pacemaker; GSM;
D O I
10.1109/IEMBS.2003.1280932
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aim of this study was to evaluate whether GSM cellular phones can affect the pacemaker (PM) functioning or the home monitoring (HM) function. We performed in vitro and in vivo tests on the BA03 PM (Biotronik, Germany). In vitro we evaluated whether the PM functioning was affected by a mobile phone or whether an improper HM procedure or an altered patient-activated HM function occurred. Two cellular phone models were used, with fixed external or internal antenna, positioned both close to the pacemaker and to the mobile cell-phone-like device, during handover, ringing and talking. All the tests have been done with the PM in air, at 900 and 1800 MHz GSM. We found that the neither the PM functioning nor the HM procedure are altered by a GSM communication. On the basis of these findings, we performed a subset of tests in 11 patients: the two phone models used for the in vitro protocol were moved both around the pacemaker implant site and the mobile cell-phone-like device at 900 MHz and 1800 MHz GSM during talking. All the patient-activated transmissions were correctly received by the service center, with a maximum transmission delay of 11 Os.
引用
收藏
页码:3602 / 3605
页数:4
相关论文
共 10 条
[1]   DO EUROPEAN GSM MOBILE CELLULAR PHONES POSE A POTENTIAL RISK TO PACEMAKER PATIENTS [J].
BARBARO, V ;
BARTOLINI, P ;
DONATO, A ;
MILITELLO, C ;
ALTAMURA, G ;
AMMIRATI, F ;
SANTINI, M .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1995, 18 (06) :1218-1224
[2]   Electromagnetic interference of analog cellular telephones with pacemakers [J].
Barbaro, V ;
Bartolini, P ;
Donato, A ;
Militello, C .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1996, 19 (10) :1410-1418
[3]  
BEEBE DJ, 1993, BIOMEDICAL DIGITAL S, P61
[4]  
CARILLO R, 1996, J AM COLL CARDIOL, V27, P901
[5]  
CARILLO R, 1995, PACE, V18, P863
[6]   Wireless phones and pacemaker interaction [J].
Hayes, DL .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1996, 19 (10) :1405-1406
[7]   Electromagnetic interference of pacemakers by mobile phones [J].
Irnich, W ;
Batz, L ;
Muller, R ;
Tobisch, R .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1996, 19 (10) :1431-1446
[8]   Is there a risk for interaction between mobile phones and single lead VDD pacemakers? [J].
Nowak, B ;
Rosocha, S ;
Zellerhoff, C ;
Liebrich, A ;
Himmrich, E ;
Voigtlander, T ;
Meyer, J .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1996, 19 (10) :1447-1450
[9]  
Ruggera Paul S., 1997, Biomedical Instrumentation and Technology, V31, P358
[10]  
Stevenson RA, 1997, P ANN INT IEEE EMBS, V19, P2558, DOI 10.1109/IEMBS.1997.756852