Terabit sampling system with photonic time-stretch analog-to-digital converter

被引:0
|
作者
Caselle, M. [1 ]
Bielawski, S. [2 ]
Manzhura, O. [1 ]
Chilingaryan, S. [1 ]
Dritschler, T. [1 ]
Ebersoldt, A. [1 ]
Kopmann, A. [1 ]
Nasse, M. J. [1 ]
Patil, M. M. [1 ]
Brundermann, E. [1 ]
Roussel, E. [2 ]
Szwaj, C. [2 ]
Muller, A-S [1 ]
机构
[1] Karlsruhe Inst Technol, Hermann von Helmholtz Pl 1, Eggenstein Leopoldshafen, Germany
[2] Univ Lille, Ctr Etud Rech & Applicat CERLA, CNRS, UMR 852,PhLAM,Phys Lasers Atomes & Mol, F-59000 Lille, France
来源
REAL-TIME MEASUREMENTS, ROGUE PHENOMENA, AND SINGLE-SHOT APPLICATIONS VII | 2022年 / 11986卷
关键词
Photonic time-stretch; femtosecond time resolution; mode-locked lasers characterization; electron bunches in accelerators; single shot measurement; ZYNQ-RFSoC; time-interleaving ADC; real-time data processing; OPTICAL COHERENCE TOMOGRAPHY; SOLITON DYNAMICS; SPECTROSCOPY; MICROSCOPY;
D O I
10.1117/12.2607818
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The detection of rapid dynamics in diverse physical systems is traditionally very difficult and strongly dominated by several noise contributions. Laser mode-locking, electron bunches in accelerators and optical-triggered phases in materials are events that carry important information about the system from which they emerge. To understand the underlying dynamics of complex systems often large numbers of single-shot measurements must be acquired continuously over a long time with extremely high temporal resolution. Ultrafast real-time instruments allow the acquisition of large data sets, even for rare events, in a relatively short time period. The real-time measurement of fast single-shot events with large record lengths is one of the most challenging problems in the fields of instrumentation and measurement. In this contribution, the novel ultra-fast and continuous data sampling system THERESA using photonic time-stretch is presented and its performance is discussed. The proposed data acquisition system is based on the latest ZYNQ Radio Frequency System on Chip (ZYNQ-RFSoC) family from Xilinx, which combines an array of fast (GS/s) multi-channel Analog-to-Digital Converters (ADCs) with a Field Programmable Gate Array (FPGA) and a multi-core ARM processor in a single heterogeneous programmable device. The stretched pulse is sampled in parallel by 16 wideband sampling channels operating in time-interleaving mode. The sampled data is transferred by a 100Gb Ethernet data link to the Data Acquisition (DAQ) compute node for further analysis. The combination of both, the photonic time-stretch and the fast sampling system, is capable of sampling short pulses with femtosecond time resolution. Applications of the new system, hardware implementation and the commissioning of the first system for the electron bunch diagnostics are presented.
引用
收藏
页数:13
相关论文
共 25 条
  • [1] Spectral Efficiency Improvement in Photonic Time-Stretch Analog-to-Digital Converter via Polarization Multiplexing
    Fard, Ali
    Buckley, Brandon
    Jalali, Bahram
    IEEE PHOTONICS TECHNOLOGY LETTERS, 2011, 23 (14) : 947 - 949
  • [2] Photonic Time-Stretch Analog-to-Digital Conversion Based on Complementary Parallel Single-Sideband Modulation Architecture
    Jin, Rongting
    Zhang, Yaowen
    Peng, Di
    Zhang, Zhiyao
    Zhang, Shangjian
    li, Heping
    Liu, Yong
    INTERNATIONAL CONFERENCE ON OPTOELECTRONIC AND MICROELECTRONIC TECHNOLOGY AND APPLICATION, 2020, 11617
  • [3] PHOTONIC ANALOG-TO-DIGITAL CONVERSION BASED ON PHOTONIC TIME STRETCH AND COMPRESSIVE SENSING WITH OPTICAL RANDOM MIXING
    Chen, Ying
    Chi, Hao
    Jin, Xiaofeng
    Zheng, Shilie
    Zhang, Xianmin
    2013 12TH INTERNATIONAL CONFERENCE ON OPTICAL COMMUNICATIONS AND NETWORKS (ICOCN), 2013,
  • [4] A Unified Framework for Photonic Time-Stretch Systems
    Zhou, Yiming
    Chan, Jacky C. K.
    Jalali, Bahram
    LASER & PHOTONICS REVIEWS, 2022, 16 (08)
  • [5] Principle and Recent Development in Photonic Time-Stretch Imaging
    Wang, Guoqing
    Zhou, Yuan
    Min, Rui
    Du, E.
    Wang, Chao
    PHOTONICS, 2023, 10 (07)
  • [6] Impact of Finite Extinction Ratio of Modulator on Photonic Time-Stretch System
    Liu, Changqiao
    Xu, Boyu
    Shen Xiaoqing
    Bo, Cong
    Jin, Xiaofeng
    Chi, Hao
    Zheng, Shilie
    Yu, Xianbin
    Zhang, Xianmin
    2017 INTERNATIONAL TOPICAL MEETING ON MICROWAVE PHOTONICS (MWP), 2017,
  • [7] High sensitivity photonic time-stretch electro-optic sampling of terahertz pulses
    Szwaj, C.
    Evain, C.
    Le Parquier, M.
    Roy, P.
    Manceron, L.
    Brubach, J. -B.
    Tordeux, M. -A.
    Bielawski, S.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2016, 87 (10)
  • [8] Data Compressed Photonic Time-Stretch Optical Coherence Tomography
    Mididoddi, Chaitanya K.
    Wang, Guoqing
    Wang, Chao
    2016 IEEE PHOTONICS CONFERENCE (IPC), 2016, : 13 - 14
  • [9] Spurious-Free Dynamic Range of the Photonic Time-Stretch System
    Mei, Yuan
    Xu, Yuxiao
    Chi, Hao
    Jin, Tao
    Zheng, Shilie
    Jin, Xiaofeng
    Zhang, Xianmin
    IEEE PHOTONICS TECHNOLOGY LETTERS, 2017, 29 (10) : 794 - 797
  • [10] High-Throughput Photonic Time-Stretch Optical Coherence Tomography with Data Compression
    Mididoddi, Chaitanya K.
    Bai, Fangliang
    Wang, Guoqing
    Liu, Jinchao
    Gibson, Stuart
    Wang, Chao
    IEEE PHOTONICS JOURNAL, 2017, 9 (04):