Measurement of electrical current density distribution in a simple head phantom with magnetic resonance imaging

被引:20
作者
Gamba, HR
Bayford, R
Holder, D
机构
[1] UCL, Dept Phys Med, London WC1E 6JA, England
[2] Middlesex Univ, London N11 2NQ, England
[3] UCL, Dept Physiol, London, ON WC1E 6JA, Canada
关键词
D O I
10.1088/0031-9155/44/1/020
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Knowledge of the influence of the human skull on the electrical current (d.c.) distribution within the brain tissue could prove useful in measuring impedance changes inside the human head. These changes can be related to physiological functions. The studies presented in this paper examine the current density distribution in a simple phantom consisting of a saline filled tank (to simulate scalp and brain) and a ring made of dental grade plaster of Paris (to simulate the human skull). Images of the distribution of the d.c. density of the phantom with and without the plaster of Paris ring were produced using a magnetic resonance imaging technique. These images indicate that the skull is likely to produce a more uniform d.c. density within the brain.
引用
收藏
页码:281 / 291
页数:11
相关论文
共 11 条
[1]   Improvement of the positional accuracy of EIT images of the head using a Lagrange multiplier reconstruction algorithm with diametric excitation [J].
Bayford, RH ;
Boone, KG ;
Hanquan, Y ;
Holder, DS .
PHYSIOLOGICAL MEASUREMENT, 1996, 17 :A49-A57
[2]   Artefacts in MR images of electrical current distribution [J].
Gamba, HR ;
Delpy, DT .
PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (12) :2481-2491
[3]   Measurement of electrical current density distribution within the tissues of the head by magnetic resonance imaging [J].
Gamba, HR ;
Delpy, DT .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1998, 36 (02) :165-170
[4]  
GAMBA HR, 1996, THESIS U COLL LONDON
[5]   ELECTRICAL-IMPEDANCE TOMOGRAPHY WITH CORTICAL OR SCALP ELECTRODES DURING GLOBAL CEREBRAL-ISCHEMIA IN THE ANESTHETIZED RAT [J].
HOLDER, DS .
CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1992, 13 (01) :87-98
[6]  
HOLDER DS, 1993, CLINICAL AND PHYSIOLOGICAL APPLICATIONS OF ELECTRICAL IMPEDANCE TOMOGRAPHY, P185
[7]  
HOLDER DS, 1993, CLINICAL AND PHYSIOLOGICAL APPLICATIONS OF ELECTRICAL IMPEDANCE TOMOGRAPHY, P166
[8]   INVIVO DETECTION OF APPLIED ELECTRIC CURRENTS BY MAGNETIC-RESONANCE IMAGING [J].
JOY, M ;
SCOTT, G ;
HENKELMAN, M .
MAGNETIC RESONANCE IMAGING, 1989, 7 (01) :89-94
[9]  
PATEL M, 1993, P SOC MAGN RES MED, V2, P721
[10]   SENSITIVITY OF MAGNETIC-RESONANCE CURRENT-DENSITY IMAGING [J].
SCOTT, GC ;
JOY, MLG ;
ARMSTRONG, RL ;
HENKELMAN, RM .
JOURNAL OF MAGNETIC RESONANCE, 1992, 97 (02) :235-254