Comparison of Two-Dimensional Shear Wave Elastography and Real-Time Tissue Elastography for Assessing Liver Fibrosis in Chronic Hepatitis B

被引:28
作者
Wu, Tao [1 ]
Wang, Ping [1 ]
Zhang, Ting [1 ]
Zheng, Jian [1 ]
Li, Shuoyang [2 ]
Zeng, Jie [1 ]
Kudo, Masatoshi [3 ]
Zheng, Rongqin [1 ]
机构
[1] Sun Yat Sen Univ, Affiliated Hosp 3, Dept Med Ultrason, Guangzhou, Guangdong, Peoples R China
[2] Sun Yat Sen Univ, Affiliated Hosp 1, Dept Radiol, Guangzhou, Guangdong, Peoples R China
[3] Kindai Univ, Fac Med, Dept Gastroenterol & Hepatol, Osaka, Japan
关键词
Shear-wave elastography; Real-time tissue elastography Hepatitis B virus; Liver fibrosis; CHRONIC VIRAL-HEPATITIS; TRANSIENT ELASTOGRAPHY; DIAGNOSTIC-ACCURACY; NONINVASIVE ASSESSMENT; STIFFNESS; CIRRHOSIS; ULTRASOUND; DISEASE; BIOPSY;
D O I
10.1159/000448825
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background: Noninvasive assessment of liver fibrosis has important clinical significance. Different techniques including two-dimensional shear-wave elastography (2D SWE) and real-time tissue elastography (RTE) are reported to be useful for the noninvasive diagnosis of hepatic fibrosis. All these techniques are affected by many factors. How to choose a reasonable method needs further studies. Purpose: This study was conducted to comparatively assess the diagnostic performance of 2D SWE and RTE in patients with Chronic Hepatitis B (CHB) and influence of inflammation on the stiffness values obtained by both techniques, so as to objectively assess the reasonable choice between these 2 elastography techniques for noninvasive assessment of hepatic fibrosis in clinical practice. Materials and Methods: Four hundred and thirty-seven patients with CHB meeting the inclusion criteria were enrolled in the study. All patients underwent liver stiffness measurements by using 2D SWE and RTE on the same day. Histologic fibrosis was staged and inflammation activity was graded based on the METAVIR scoring system on liver biopsy specimens. Results: The liver stiffness values by using 2D SWE and RTE both increased in parallel with the degree of liver fibrosis and the grade of inflammation. However, the diagnostic efficacy of significant fibrosis and cirrhosis using 2D SWE was significantly higher than that of RTE. The 2D SWE measurement values were statistically different in different alanine aminotransferase (ALT) levels and METAVIR activity grades; however, no statistically significant differences were observed by using RTE. The diagnostic efficacy of 2D SWE significantly varied with elevated ALT levels compared with RTE. Conclusion: 2D SWE was more accurate than RTE in the assessment of significant fibrosis and cirrhosis in patients with CHB. Compared with RTE, the measurement values and diagnostic performance obtained by 2D SWE were prone to be more easily affected by the inflammation fluctuations. (C) 2016 S. Karger AG, Basel
引用
收藏
页码:640 / 649
页数:10
相关论文
共 40 条
[1]  
Altman DG, 2000, Statistics with confidence, V2nd
[2]   Acute viral hepatitis increases liver stiffness values measured by transient elastography [J].
Arena, Umberto ;
Vizzutti, Francesco ;
Corti, Giampaolo ;
Ambu, Silvia ;
Stasi, Cristina ;
Bresci, Silvia ;
Moscarella, Stefania ;
Boddi, Vied ;
Petrarca, Antonio ;
Laffi, Giacomo ;
Marra, Fabio ;
Pinzani, Massimo .
HEPATOLOGY, 2008, 47 (02) :380-384
[3]   An algorithm for the grading of activity in chronic hepatitis C [J].
Bedossa, P ;
Poynard, T .
HEPATOLOGY, 1996, 24 (02) :289-293
[4]   Practices of liver biopsy in France: Results of a prospective nationwide survey [J].
Cadranel, JF ;
Rufat, P ;
Degos, F .
HEPATOLOGY, 2000, 32 (03) :477-481
[5]   Non-invasive assessment of liver fibrosis with impulse elastography: Comparison of Supersonic Shear Imaging with ARFI and FibroScan [J].
Cassinotto, Christophe ;
Lapuyade, Bruno ;
Mouries, Amaury ;
Hiriart, Jean-Baptiste ;
Vergniol, Julien ;
Gaye, Delphine ;
Castain, Claire ;
Le Bail, Brigitte ;
Chermak, Faiza ;
Foucher, Juliette ;
Laurent, Francois ;
Montaudon, Michel ;
De Ledinghen, Victor .
JOURNAL OF HEPATOLOGY, 2014, 61 (03) :550-557
[6]   COMPARING THE AREAS UNDER 2 OR MORE CORRELATED RECEIVER OPERATING CHARACTERISTIC CURVES - A NONPARAMETRIC APPROACH [J].
DELONG, ER ;
DELONG, DM ;
CLARKEPEARSON, DI .
BIOMETRICS, 1988, 44 (03) :837-845
[7]   Transient elastography using Fibroscan is the most reliable noninvasive method for the diagnosis of advanced fibrosis and cirrhosis in alcoholic liver disease [J].
Fernandez, Michael ;
Trepo, Eric ;
Degre, Delphine ;
Gustot, Thierry ;
Verset, Laurine ;
Demetter, Pieter ;
Deviere, Jacques ;
Adler, Michael ;
Moreno, Christophe .
EUROPEAN JOURNAL OF GASTROENTEROLOGY & HEPATOLOGY, 2015, 27 (09) :1074-1079
[8]   Shear Wave Elastography for Evaluation of Liver Fibrosis [J].
Ferraioli, Giovanna ;
Parekh, Parth ;
Levitov, Alexander B. ;
Filice, Carlo .
JOURNAL OF ULTRASOUND IN MEDICINE, 2014, 33 (02) :197-203
[9]   Accuracy of Real-Time Shear Wave Elastography for Assessing Liver Fibrosis in Chronic Hepatitis C: A Pilot Study [J].
Ferraioli, Giovanna ;
Tinelli, Carmine ;
Dal Bello, Barbara ;
Zicchetti, Mabel ;
Filice, Gaetano ;
Filice, Carlo .
HEPATOLOGY, 2012, 56 (06) :2125-2133
[10]   Diagnosis of cirrhosis by transient elastography (FibroScan):: a prospective study [J].
Foucher, J ;
Chanteloup, E ;
Vergniol, J ;
Castéra, L ;
Le Bail, B ;
Adhoute, X ;
Bertet, J ;
Couzigou, P ;
de Lédinghen, V .
GUT, 2006, 55 (03) :403-408