Differentiation Between Granulomatous Lobular Mastitis and Breast Cancer Using Quantitative Parameters on Contrast-Enhanced Ultrasound

被引:12
作者
Yin, Liang [1 ]
Agyekum, Enock Adjei [2 ]
Zhang, Qing [2 ]
Pan, Lei [1 ]
Wu, Ting [3 ]
Xiao, Xiudi [1 ]
Qian, Xiao-qin [2 ]
机构
[1] Jiangsu Univ, Affiliated Peoples Hosp, Dept Breast Surg, Zhenjiang, Peoples R China
[2] Jiangsu Univ, Affiliated Peoples Hosp, Dept Ultrasound, Zhenjiang, Peoples R China
[3] Jiangsu Univ, Affiliated Peoples Hosp, Dept Pathol, Zhenjiang, Peoples R China
关键词
granulomatous mastitis; breast cancer; quantitative parameters; imaging characteristics; contrasted-enhanced ultrasound; BENIGN; ELASTOGRAPHY; DIAGNOSIS; LESIONS;
D O I
10.3389/fonc.2022.876487
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
ObjectiveTo investigate the Contrast-enhanced ultrasound (CEUS) imaging characteristics of granulomatous lobular mastitis (GLM) and the value of differentiating GLM from breast cancer. Materials and methodsThe study included 30 women with GLM (mean age 36.7 +/- 5 years [SD]) and 58 women with breast cancer (mean age 48. +/- 8 years [SD]) who were scheduled for ultrasound-guided tissue biopsy. All patients were evaluated with conventional US and CEUS prior to the biopsy. In both groups, the parameters of the quantitative and qualitative analysis of the CEUS were recorded and compared. The receiver-operating-characteristics curves (ROC) were created. Sensitivity, specificity, cut-off, and area under the curve (AUC) values were calculated. ResultsTTP values in GLM were statistically higher than in breast cancer (mean, 27.63 +/- 7.29 vs. 20.10 +/- 6.11), but WIS values were lower (mean, 0.16 +/- 0.05 vs. 0.28 +/- 0.17). Rich vascularity was discovered in 54.45% of breast cancer patients, but only 30.00% of GLM patients had rich vascularity. The AUC for the ROC test was 0.791 and 0.807, respectively. The optimal cut-off value for TTP was 24.5s, and the WIS cut-off value was 0.185dB/s, yielding 73.33% sensitivity, 84.48% specificity, and 86.21% sensitivity, 70% specificity respectively in the diagnosis of GLM. The lesion scores reduced from 4 to 3 with the addition of CEUS for the patients with GLM. However, the scores did not change for the patients with breast cancer. ConclusionCEUS could help distinguish GLM from breast cancer by detecting higher TTP and WIS values, potentially influencing clinical decision-making for additional biopsies.
引用
收藏
页数:7
相关论文
共 29 条
[1]   Advantages of b-mode ultrasound combined with strain elastography in differentiation of idiopathic granulomatous mastitis from malignant breast lesions [J].
Arslan, Serdar ;
Oncu, Fatih ;
Eryilmaz, Mehmet Ali ;
Durmaz, Mehmet Sedat ;
Altunkeser, Aysegul ;
Unlu, Yasar .
TURKISH JOURNAL OF MEDICAL SCIENCES, 2018, 48 (01) :16-23
[2]   Magnetic resonance imaging characteristics of granulomatous mastitis [J].
Chu, Amanda N. ;
Seiler, Stephen J. ;
Hayes, Jody C. ;
Wooldridge, Rachel ;
Porembka, Jessica H. .
CLINICAL IMAGING, 2017, 43 :199-201
[3]   Role of Superb Microvascular Imaging in Differentiating Between Malignant and Benign Solid Breast Masses [J].
Diao, Xuehong ;
Zhan, Jia ;
Chen, Lin ;
Chen, Yue ;
Cao, Hongli .
CLINICAL BREAST CANCER, 2020, 20 (06) :E786-E793
[4]  
Dietrich CF, 2020, ULTRASCHALL MED, V41, P562, DOI [10.1055/a-1177-0530, 10.1016/j.ultrasmedbio.2020.04.030]
[5]   Differentiating benign from malignant solid breast lesions: Combined utility of conventional ultrasound and contrast-enhanced ultrasound in comparison with magnetic resonance imaging [J].
Du, Jing ;
Wang, Lin ;
Wan, Cai-Feng ;
Hua, Jia ;
Fang, Hua ;
Chen, Jie ;
Li, Feng-Hua .
EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (12) :3890-3899
[6]   The clinical value of Arrival-time Parametric Imaging using contrast-enhanced ultrasonography in differentiating benign and malignant breast lesions [J].
Hu, Wenjie ;
Dong, Yi ;
Zhang, Xuemei ;
Zhang, Huiping ;
Li, Fan ;
Bai, Min .
CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2020, 75 (03) :369-382
[7]   Prospective evaluation of contrast-enhanced ultrasound of breast BI-RADS 3-5 lesions [J].
Janu, Eva ;
Krikavova, Lucie ;
Little, Jirina ;
Dvorak, Karel ;
Brancikova, Dagmar ;
Jandakova, Eva ;
Pavlik, Tomas ;
Kovalcikova, Petra ;
Kazda, Tomas ;
Valek, Vlastimil .
BMC MEDICAL IMAGING, 2020, 20 (01)
[8]   Quantification of dynamic contrast-enhanced ultrasound (CEUS) in non-cystic breast lesions using external perfusion software [J].
Jung, Ernst Michael ;
Jung, Friedrich ;
Stroszczynski, Christian ;
Wiesinger, Isabel .
SCIENTIFIC REPORTS, 2021, 11 (01)
[9]   SonoVue(R) vs. Sonazoid™ vs. Optison™: Which Bubble Is Best for Low-Intensity Sonoporation of Pancreatic Ductal Adenocarcinoma? [J].
Kotopoulis, Spiros ;
Popa, Mihaela ;
Mayoral Safont, Mireia ;
Murvold, Elisa ;
Haugse, Ragnhild ;
Langer, Anika ;
Dimcevski, Georg ;
Lam, Christina ;
Bjanes, Tormod ;
Gilja, Odd Helge ;
Mc Cormack, Emmet .
PHARMACEUTICS, 2022, 14 (01)
[10]   Granulomatous Lobular Mastitis: Imaging, Diagnosis, and Treatment [J].
Larsen, Linda J. Hovanessian ;
Peyvandi, Banafsheh ;
Klipfel, Nancy ;
Grant, Edward ;
Iyengar, Geeta .