Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry for the identification of beta-hemolytic streptococci

被引:2
作者
Zhou, Chunmei [1 ]
Tao, Lili [2 ]
Hu, Bijie [3 ]
Ma, Jian [4 ]
Ye, Xiangru [3 ]
Huang, Shenglei [1 ]
Ma, Yan [1 ]
Shan, Yuzhang [1 ]
机构
[1] Fudan Univ, Zhongshan Hosp, Dept Clin Microbiol Lab, Shanghai 200032, Peoples R China
[2] Fudan Univ, Huangdong Hosp, Dept Resp Med, Shanghai 200040, Peoples R China
[3] Fudan Univ, Zhongshan Hosp, Dept Resp Med, Shanghai 200032, Peoples R China
[4] Ningbo Univ, Yingzhou Hosp, Dept Resp Med, Ningbo 315040, Zhejiang, Peoples R China
关键词
Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS); MS; beta-hemolytic streptococci (BHS); identification; DESORPTION IONIZATION-TIME; RELEVANT ANAEROBIC-BACTERIA; RAPID IDENTIFICATION; MICROBIOLOGY; LABORATORIES; SYSTEM; MS; MULTICENTER;
D O I
10.3978/j.issn.2072-1439.2015.03.02
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Objective: Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) has emerged as promising technology for species identification. The purpose of this investigation was to compare the performance of MS and the traditional method for identification of beta-hemolytic streptococci (BHS). Methods: Clinical BHS isolates were identified by the BD Phoenix SMIC/ID Streptococcal panels, and two MALDI-TOF MS platforms: the VITEK MS and the Bruker MALDI Biotyper systems respectively. In case of discordant results, 16sRNA sequencing was performed to provide the reference ID. Results: A total of 96 isolates of BHS were analyzed. Thirty-six isolates (20.8%) were re-tested by BD Phoenix for identification failure; and four isolates (4.2%) were rerun on the Bruker system for low identification score. No isolate need a second run for identification by Vitek MS system. Overall, BD Phoenix, BioTyper and Vitek MS automated system accurately identified 76 strains (79.2%), 91 (94.7%) strains and 92 (95.8%) strains, respectively. Conclusions: Our study suggests that MALDI-TOF MS is a superior method to conventional phenotypic methods for BHS identification.
引用
收藏
页码:591 / 595
页数:5
相关论文
共 15 条
[1]   Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry as an Alternative to 16S rRNA Gene Sequencing for Identification of Difficult-To-Identify Bacterial Strains [J].
Bizzini, A. ;
Jaton, K. ;
Romo, D. ;
Bille, J. ;
Prod'hom, G. ;
Greub, G. .
JOURNAL OF CLINICAL MICROBIOLOGY, 2011, 49 (02) :693-696
[2]   Evaluation of Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry for Rapid Identification of Beta-Hemolytic Streptococci [J].
Cherkaoui, Abdessalam ;
Emonet, Stephane ;
Fernandez, Jose ;
Schorderet, Didier ;
Schrenzel, Jacques .
JOURNAL OF CLINICAL MICROBIOLOGY, 2011, 49 (08) :3004-3005
[3]   Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry: a Fundamental Shift in the Routine Practice of Clinical Microbiology [J].
Clark, Andrew E. ;
Kaleta, Erin J. ;
Arora, Amit ;
Wolk, Donna M. .
CLINICAL MICROBIOLOGY REVIEWS, 2013, 26 (03) :547-603
[4]   The rapid identification of intact microorganisms using mass spectrometry [J].
Claydon, MA ;
Davey, SN ;
EdwardsJones, V ;
Gordon, DB .
NATURE BIOTECHNOLOGY, 1996, 14 (11) :1584-1586
[5]  
Holland RD, 1996, RAPID COMMUN MASS SP, V10, P1227, DOI 10.1002/(SICI)1097-0231(19960731)10:10<1227::AID-RCM659>3.0.CO
[6]  
2-6
[7]  
Kumar MP, 2004, INDIAN J MED RES, V119, P283
[8]   Matrix-assisted laser desorption ionisation time-of-flight mass spectrometry for identification of clinically significant bacteria that are difficult to identify in clinical laboratories [J].
Lau, Susanna K. P. ;
Tang, Bone S. F. ;
Teng, Jade L. L. ;
Chan, Tsz-Ming ;
Curreem, Shirly O. T. ;
Fan, Rachel Y. Y. ;
Ng, Ricky H. Y. ;
Chan, Jasper F. W. ;
Yuen, Kwok-Yung ;
Woo, Patrick C. Y. .
JOURNAL OF CLINICAL PATHOLOGY, 2014, 67 (04) :361-366
[9]   Accuracy of Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry for Identification of Clinical Pathogenic Fungi: a Meta-Analysis [J].
Ling, Huazhi ;
Yuan, Zhijie ;
Shen, Jilu ;
Wang, Zhongxin ;
Xu, Yuanhong .
JOURNAL OF CLINICAL MICROBIOLOGY, 2014, 52 (07) :2573-2582
[10]   The value of MALDI-TOF MS for the identification of clinically relevant anaerobic bacteria in routine laboratories [J].
Nagy, Elisabeth ;
Becker, Simone ;
Kostrzewa, Markus ;
Barta, Noemi ;
Urban, Edit .
JOURNAL OF MEDICAL MICROBIOLOGY, 2012, 61 (10) :1393-1400