Ultrasound to Detect Central Venous Catheter Placement Associated Complications A Multicenter Diagnostic Accuracy Study

被引:18
|
作者
Smit, Jasper M. [1 ,2 ]
Haaksma, Mark E. [1 ,2 ]
Lim, Endry H. T. [1 ,2 ]
Steenvoorden, Thei S. [1 ,2 ]
Blans, Michiel J. [3 ]
Bosch, Frank H. [3 ]
Petjak, Manfred [4 ]
Vermin, Ben [4 ]
Touw, Hugo R. W. [1 ,2 ]
Girbes, Armand R. J. [1 ,2 ]
Heunks, Leo M. A. [1 ,2 ]
Tuinman, Pieter R. [1 ,2 ]
机构
[1] Vrije Univ Amsterdam, Res VU Univ Med Ctr VUmc Intens Care, Amsterdam Cardiovasc Sci, Dept Intens Care Med,Amsterdam Univ,Med Ctr, Amsterdam, Netherlands
[2] Vrije Univ Amsterdam, Amsterdam Infect & Immun Inst, Amsterdam Univ, Med Ctr, Amsterdam, Netherlands
[3] Rijnstate Hosp, Dept Intens Care Med, Arnhem, Netherlands
[4] Groene Hart Hosp, Dept Intens Care Med, Gouda, Netherlands
关键词
LUNG ULTRASOUND; CHEST RADIOGRAPHY; TIP POSITION; CONFIRMATION; PNEUMOTHORAX; BUBBLE; POINT;
D O I
10.1097/ALN.0000000000003126
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: Mechanical complications arising after central venous catheter placement are mostly malposition or pneumothorax. To date, to confirm correct position and detect pneumothorax, chest x-ray film has been the reference standard, while ultrasound might be an accurate alternative. The aim of this study was to evaluate diagnostic accuracy of ultrasound to detect central venous catheter malposition and pneumothorax. Methods: This was a prospective, multicenter, diagnostic accuracy study conducted at the intensive care unit and postanesthesia care unit. Adult patients who underwent central venous catheterization of the internal jugular vein or subclavian vein were included. Index test consisted of venous, cardiac, and lung ultrasound. Standard reference test was chest x-ray film. Primary outcome was diagnostic accuracy of ultrasound to detect malposition and pneumothorax; for malposition, sensitivity, specificity, and other accuracy parameters were estimated. For pneumothorax, because chest x-ray film is an inaccurate reference standard to diagnose it, agreement and Cohen's kappa-coefficient were determined. Secondary outcomes were accuracy of ultrasound to detect clinically relevant complications and feasibility of ultrasound. Results: In total, 758 central venous catheterizations were included. Malposition occurred in 23 (3.3%) out of 688 cases included in the analysis. Ultrasound sensitivity was 0.70 (95% CI, 0.49 to 0.86) and specificity 0.99 (95% CI, 0.98 to 1.00). Pneumothorax occurred in 5 (0.7%) to 11 (1.5%) out of 756 cases according to chest x-ray film and ultrasound, respectively. In 748 out of 756 cases (98.9%), there was agreement between ultrasound and chest x-ray film with a Cohen's kappa-coefficient of 0.50 (95% CI, 0.19 to 0.80). Conclusions: This multicenter study shows that the complication rate of central venous catheterization is low and that ultrasound produces a moderate sensitivity and high specificity to detect malposition. There is moderate agreement with chest x-ray film for pneumothorax. In conclusion, ultrasound is an accurate diagnostic modality to detect malposition and pneumothorax.
引用
收藏
页码:781 / 794
页数:14
相关论文
共 50 条
  • [31] Assistive technology for ultrasound-guided central venous catheter placement
    Mohammad Ikhsan
    Kok Kiong Tan
    Andi Sudjana Putra
    Journal of Medical Ultrasonics, 2018, 45 : 41 - 57
  • [32] Central venous catheter placement assisted by obstetrical ultrasound - A case report
    Furs, CM
    Muir, HA
    Habib, A
    DeBalli, P
    Schultz, JR
    ANESTHESIOLOGY, 2003, 98 : 33 - 33
  • [33] Decrease in Central Venous Catheter Placement and Complications Due to Utilization of Ultrasound-Guided Peripheral Intravenous Catheters
    Au, A.
    Rotte, M.
    Gryzbowski, R.
    Ku, B.
    Fields, J.
    ANNALS OF EMERGENCY MEDICINE, 2011, 58 (04) : S230 - S230
  • [34] Proximal Median Neuropathy with Brachial Plexitis After PICC Placement; a Case Study and Review of Neurologic Complications Associated with Central Venous Catheter Placement
    Seligman, Christa
    Woodman, Karin
    NEUROLOGY, 2019, 92 (15)
  • [35] Prevalence of complications associated with central venous catheter instalation for hemodyalisis
    Mueller-Ortiz, Hans
    Tian Pedreros-Rosales, Cris
    Pablo Silva-Carvajal, Juan
    Kraunik-Rodriguez, David
    Vera-Calzaretta, Aldo
    Gonzalez-Burboa, Alexis
    Cament-Munoz, Rene
    Taylor-Montoya, Susan
    Mueller-Henriquez, Natalia
    Chavez-Campodonico, Tatiana
    Rivas-Calabran, Luisa
    REVISTA MEDICA DE CHILE, 2019, 147 (04) : 458 - 464
  • [36] Life-threatening vascular complications after central venous catheter placement
    S. Wicky
    J.-Y. Meuwly
    F. Doenz
    A. Uské
    P. Schnyder
    A. Denys
    European Radiology, 2002, 12 : 901 - 907
  • [37] COMPLICATIONS FROM CENTRAL VENOUS CATHETER PLACEMENT IN TWO LARGE TERTIARY HOSPITALS
    Goyal, Munish
    Bell, Jake
    Blythe, Kevin
    Fitzgibbons, Shimae
    Chung, Suzi
    Molyneaux, Robert
    CRITICAL CARE MEDICINE, 2014, 42 (12)
  • [38] CENTRAL VENOUS CATHETER PLACEMENT WITH IMPLANTABLE PORT IN ONCOLOGIC PATIENTS POSTOPERATIVE COMPLICATIONS
    Federico, Dieguez Aliaga
    Carlos, Larsson Juan
    Sebastin, Garcia
    Roberto, Badra
    Guillermo, Romero Reyna
    REVISTA ARGENTINA DE RESIDENTES DE CIRUGIA, 2012, 17 (02): : 30 - 33
  • [39] Life-threatening vascular complications after central venous catheter placement
    Wicky, S
    Meuwly, JY
    Doenz, F
    Uské, A
    Schnyder, P
    Denys, A
    EUROPEAN RADIOLOGY, 2002, 12 (04) : 901 - 907
  • [40] Central venous catheter placement in children
    Towbin, RB
    Sane, SS
    Arumanla, S
    Kaye, RD
    Fitz, CR
    RADIOLOGY, 1998, 209P : 454 - 454