Lateral performance of midply wood shear walls with anchor tie-down system: Experimental investigation and numerical simulation

被引:18
作者
Guo, Suyi [1 ]
He, Minjuan [1 ]
Li, Zheng [1 ]
Liang, Feng [2 ]
Chen, Fei [1 ]
Sun, Yongliang [2 ]
Briseghella, Bruno [3 ]
He, Guirong [2 ]
机构
[1] Tongji Univ, Dept Struct Engn, Shanghai 200092, Peoples R China
[2] Tongji Architectural Design Grp Co Ltd, Shanghai 200092, Peoples R China
[3] Fuzhou Univ, Coll Civil Engn, Fuzhou 350116, Peoples R China
基金
国家重点研发计划; 中国国家自然科学基金;
关键词
Midply wood shear wall; Anchor tie-down system (ATS); Cyclic loading test; Finite element modeling; CONNECTIONS; RESISTANCE; BEHAVIOR; MODEL;
D O I
10.1016/j.conbuildmat.2019.117518
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents experimental and numerical studies on the lateral performance of midply wood shear walls. A kind of anchor tie-down system (ATS) is introduced into the wood shear wall, and two different wall-foundation connections (i.e., screwed connection and bolted connection) are considered. Reserved cyclic loading tests were conducted to investigate the failure modes, lateral load resisting capacity, stiffness degradation, and energy dissipation of four midply wood shear wall specimens. Test results show that with the installation of ATS, the lateral load resisting capacity, energy dissipation, and lateral stiffness of the specimen increased by 154%, 427%, and 93%, respectively. The pull-out failure of the wall studs was also avoided with the application of ATS. Compared with the midply wood shear wall specimens with bolted wall-foundation connection, the specimens with screwed wall-foundation connection dissipated more energy; however, the fatigue failure of the screws might lead to brittle failure of the shear wall. A nonlinear finite element model of the midply wood shear wall was then developed and verified with the test results. User-defined Q-pinch model was applied to simulate the sheathing-framing connection of the shear wall. The simulation results show that the hysteretic behavior of the specimen with ATS was well predicted. The experimental and numerical studies provide fundamental knowledge for the development and application of midply wood shear walls, especially for the application of such wall system into mid-rise timber structures. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页数:12
相关论文
共 33 条
[1]  
[Anonymous], THESIS
[2]  
[Anonymous], 2006, GBT12312006 CMIF
[3]  
[Anonymous], 2017, 50017 GB NSPRC
[4]  
[Anonymous], 2022, NLGA standard grading rules for canadian lumberS, Nat. Lumb. Grades Author
[5]  
[Anonymous], ABAQUS VERS 6 10 COM
[6]  
ASTM, 2005, 212602A ASTM E PA US
[7]   CLT-Steel Hybrid System: Ductility and Overstrength Values Based on Static Pushover Analysis [J].
Dickof, C. ;
Stiemer, S. F. ;
Bezabeh, M. A. ;
Tesfamariam, S. .
JOURNAL OF PERFORMANCE OF CONSTRUCTED FACILITIES, 2014, 28 (06)
[8]  
Dong W., 2017, THESIS
[9]   Seismic resistance of wood shear walls with large OSB panels [J].
Durham, J ;
Lam, F ;
Prion, HGL .
JOURNAL OF STRUCTURAL ENGINEERING, 2001, 127 (12) :1460-1466
[10]   Seismic analysis of woodframe structures. I: Model formulation [J].
Folz, B ;
Filiatrault, A .
JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2004, 130 (09) :1353-1360