Two-color laser-induced incandescence (2C-LII) technique for absolute soot volume fraction measurements in flames

被引:66
作者
De Luliis, S [1 ]
Cignoli, F [1 ]
Zizak, G [1 ]
机构
[1] CNR, IENI, I-20125 Milan, Italy
关键词
D O I
10.1364/AO.44.007414
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A two-color version of the laser-induced incandescence (2C-LII) technique was implemented for measuring absolute soot volume fraction in flames. By using a calibrated tungsten ribbon lamp, soot peak temperatures were measured as a function of fluence at several locations in an ethylene diffusion flame by using a steeply edged laser beam profile. Above a certain fluence threshold, peak temperatures were tightly distributed just above 4000 K independent of the particle size and number density. Radial profiles of soot volume fraction were obtained and compared (not calibrated) with results from the laser extinction technique. Good agreement showed the validity of the 2C-LII technique at a controlled fluence. (c) 2005 Optical Society of America.
引用
收藏
页码:7414 / 7423
页数:10
相关论文
共 50 条
[21]   Two-dimensional laser-induced incandescence for soot volume fraction measurements: issues in quantification due to laser beam focusing [J].
Manu Mannazhi ;
Per-Erik Bengtsson .
Applied Physics B, 2020, 126
[22]   Laser-induced incandescence for soot particle size measurements in premixed flat flames [J].
Axelsson, B ;
Collin, R ;
Bengtsson, PE .
APPLIED OPTICS, 2000, 39 (21) :3683-3690
[23]   Comprehensive two-dimensional soot diagnostics based on laser-induced incandescence (LII) [J].
Will, S ;
Schraml, S ;
Leipertz, A .
TWENTY-SIXTH SYMPOSIUM (INTERNATIONAL) ON COMBUSTION, VOLS 1 AND 2, 1996, :2277-2284
[24]   Measurement of soot volume fraction and primary particle diameter in oxygen enriched ethylene diffusion flames using the laser-induced incandescence technique [J].
Zhang, Yindi ;
Liu, Fengshan ;
Clavel, Daniel ;
Smallwood, Gregory J. ;
Lou, Chun .
ENERGY, 2019, 177 :421-432
[25]   Improvement in soot concentration measurements by laser-induced incandescence (LII) through a particle size correction [J].
Reimann, J. ;
Kuhlmann, S. -A. ;
Will, S. .
COMBUSTION AND FLAME, 2008, 153 (04) :650-654
[26]   Measurements of soot volume fraction in pulsed diffusion flame by laser induced incandescence [J].
Sapmaz, Hayri ;
Lin, Cheng-Xian ;
Ghenai, Chaouki .
EXPERIMENTS IN FLUIDS, 2008, 44 (01) :137-144
[27]   Soot volume fraction measurements in aero-engine model combustor outlet using two-color laserinduced incandescence [J].
Linsen WANG ;
Pengji DING ;
Sijie YAN ;
Jie LI ;
Jingwei Zhang ;
Chaozong WANG ;
Zhibo CAO ;
Quan ZHOU ;
Jinhe MU ;
Gang Meng ;
Wenyan SONG ;
Zhenyu XU ;
Bo Yan ;
Shuang CHEN .
Chinese Journal of Aeronautics, 2025, 38 (03) :253-265
[28]   Measurements of soot volume fraction in pulsed diffusion flame by laser induced incandescence [J].
Hayri Sapmaz ;
Cheng-Xian Lin ;
Chaouki Ghenai .
Experiments in Fluids, 2008, 44 :137-144
[29]   Can laser-induced incandescence calibrated by laser extinction method be used for quantitative determination of soot volume fraction in laminar flames? [J].
Zhang, Zijian ;
Zhou, Lei ;
He, Xiaozhou .
APPLICATIONS IN ENERGY AND COMBUSTION SCIENCE, 2023, 13
[30]   Sensitivity and relative error analyses of soot temperature and volume fraction determined by two-color LII [J].
F. Liu ;
D. R. Snelling ;
K. A. Thomson ;
G. J. Smallwood .
Applied Physics B, 2009, 96 :623-636