Optimizing the subwavelength grating of L-band annular groove phase masks for high coronagraphic performance

被引:26
作者
Catalan, E. Vargas [1 ]
Huby, E. [2 ]
Forsberg, P. [1 ]
Jolivet, A. [2 ]
Baudoz, P. [3 ]
Carlomagno, B. [2 ]
Delacroix, C. [4 ]
Habraken, S. [2 ]
Mawet, D. [5 ,6 ]
Surdej, J. [2 ]
Absil, O. [2 ]
Karlsson, M. [1 ]
机构
[1] Uppsala Univ, Dept Engn Sci, Angstrom Lab, POB 534, S-75121 Uppsala, Sweden
[2] Univ Liege, Space Sci Technol & Astrophys Res STAR Inst, 19c Allee Six Aout, B-4000 Liege, Belgium
[3] Univ Paris Diderot, UPMC Univ Paris 06, CNRS, LESIA Observ Paris, 5 Pl J Janssen, F-92195 Meudon, France
[4] Cornell Univ, Sibley Sch Mech & Aerosp Engn, Ithaca, NY 14853 USA
[5] CALTECH, Dept Astron, 1200 E Calif Blvd,MC 249-17, Pasadena, CA 91125 USA
[6] CALTECH, Jet Prop Lab, 4800 Oak Grove Dr, Pasadena, CA 91109 USA
来源
ASTRONOMY & ASTROPHYSICS | 2016年 / 595卷
基金
欧洲研究理事会; 瑞典研究理事会;
关键词
instrumentation: high angular resolution; planetary systems; planets and satellites: detection; VECTOR VORTEX CORONAGRAPH; 1ST LIGHT; DIAMOND; FABRICATION; SURFACES;
D O I
10.1051/0004-6361/201628739
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
Context. The annular groove phase mask (AGPM) is one possible implementation of the vector vortex coronagraph, where the helical phase ramp is produced by a concentric subwavelength grating. For several years, we have been manufacturing AGPMs by etching gratings into synthetic diamond substrates using inductively coupled plasma etching. Aims. We aim to design, fabricate, optimize, and evaluate new L-band AGPMs that reach the highest possible coronagraphic performance, for applications in current and forthcoming infrared high-contrast imagers. Methods. Rigorous coupled wave analysis (RCWA) is used for designing the subwavelength grating of the phase mask. Coronagraphic performance evaluation is performed on a dedicated optical test bench. The experimental results of the performance evaluation are then used to accurately determine the actual profile of the fabricated gratings, based on RCWA modeling. Results. The AGPM coronagraphic performance is very sensitive to small errors in etch depth and grating profile. Most of the fabricated components therefore show moderate performance in terms of starlight rejection (a few 100: 1 in the best cases). Here we present new processes for re-etching the fabricated components in order to optimize the parameters of the grating and hence significantly increase their coronagraphic performance. Starlight rejection up to 1000: 1 is demonstrated in a broadband L filter on the coronagraphic test bench, which corresponds to a raw contrast of about 10 5 at two resolution elements from the star for a perfect input wave front on a circular, unobstructed aperture. Conclusions. Thanks to their exquisite performance, our latest L-band AGPMs are good candidates for installation in state of the art and future high-contrast thermal infrared imagers, such as METIS for the E-ELT.
引用
收藏
页数:8
相关论文
共 20 条
  • [1] Boccaletti A., 2008, P SOC PHOTO-OPT INS, V7015, P70156
  • [2] METIS: the Mid-infrared E-ELT Imager and Spectrograph
    Brandl, Bernhard R.
    Feldt, Markus
    Glasse, Alistair
    Guedel, Manuel
    Heikamp, Stephanie
    Kenworthy, Matthew
    Lenzen, Rainer
    Meyer, Michael R.
    Molster, Frank
    Paalvast, Sander
    Pantin, Eric J.
    Quanz, Sascha P.
    Schmalzl, Eva
    Stuik, Remko
    Venema, Lars
    Waelkens, Christoffel
    [J]. GROUND-BASED AND AIRBORNE INSTRUMENTATION FOR ASTRONOMY V, 2014, 9147
  • [3] Controlling the profile of high aspect ratio gratings in diamond
    Catalan, Ernesto Vargas
    Forsberg, Pontus
    Absil, Olivier
    Karlsson, Mikael
    [J]. DIAMOND AND RELATED MATERIALS, 2016, 63 : 60 - 68
  • [4] Defrere D., 2014, P SOC PHOTO-OPT INS, V9148, P91483
  • [5] Laboratory demonstration of a mid-infrared AGPM vector vortex coronagraph
    Delacroix, C.
    Absil, O.
    Forsberg, P.
    Mawet, D.
    Christiaens, V.
    Karlsson, M.
    Boccaletti, A.
    Baudoz, P.
    Kuittinen, M.
    Vartiainen, I.
    Surdej, J.
    Habraken, S.
    [J]. ASTRONOMY & ASTROPHYSICS, 2013, 553
  • [6] Delacroix C., 2012, P SOC PHOTO-OPT INS, V8446, P84468
  • [7] Design, manufacturing, and performance analysis of mid-infrared achromatic half-wave plates with diamond subwavelength gratings
    Delacroix, Christian
    Forsberg, Pontus
    Karlsson, Mikael
    Mawet, Dimitri
    Absil, Olivier
    Hanot, Charles
    Surdej, Jean
    Habraken, Serge
    [J]. APPLIED OPTICS, 2012, 51 (24) : 5897 - 5902
  • [8] Optical vortex coronagraph
    Foo, G
    Palacios, DM
    Swartzlander, GA
    [J]. OPTICS LETTERS, 2005, 30 (24) : 3308 - 3310
  • [9] High aspect ratio optical gratings in diamond
    Forsberg, Pontus
    Karlsson, Mikael
    [J]. DIAMOND AND RELATED MATERIALS, 2013, 34 : 19 - 24
  • [10] Reflection/transmission confocal microscopy characterization of single-crystal diamond microlens arrays
    Gu, E
    Choi, HW
    Liu, C
    Griffin, C
    Girkin, JM
    Watson, IM
    Dawson, MD
    McConnell, G
    Gurney, AM
    [J]. APPLIED PHYSICS LETTERS, 2004, 84 (15) : 2754 - 2756