Improving diagnosis of von Willebrand disease: Reference ranges for von Willebrand factor multimer distribution

被引:15
作者
Vangenechten, Inge [1 ,2 ]
Gadisseur, Alain [1 ,2 ,3 ]
机构
[1] Antwerp Univ Hosp, Dept Haematol, Haemostasis Unit, Wilrijkstr 10, B-2650 Edegem, Belgium
[2] Antwerp Univ, von Willebrand Dis, Antwerp, Belgium
[3] Antwerp Univ, Haemostasis Res Unit, Antwerp, Belgium
关键词
classification; densitometry; multimers; quantification; reference values; von Willebrand disease; INDUCED PLATELET-AGGREGATION; VONWILLEBRAND-FACTOR; 2M; CLASSIFICATION; PHENOTYPE; MUTATION; BINDING; ASSAY; VARIABILITY; MANAGEMENT;
D O I
10.1002/rth2.12408
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Phenotypic von Willebrand disease (VWD) classification requires multiple tests including analysis of multimeric distributions von Willebrand factor (VWF) and evaluation of its structure. VWF multimer analysis is labor intensive, nonstandardized, and limited to specialized laboratories. A commercial semiautomatic assay, HYDRAGEL VW multimer assay (H5/11VWM, Sebia), has become available. Objectives: Establishment of reference ranges for H5/11VWM to improve VWD classification. Methods: Implementation validation, establishment and validation of normal and pathological reference intervals (NRIs/PRIs), comparison with in-house method using 40 healthy volunteers and 231 VWD patients. Results: Qualitative and quantitative validation of NRI obtained sensitivity of 88% and 79%, respectively, for type 2. Comparison of the two methods showed an overall concordance of 86% with major conflicting results in all atypical 2B (n = 7) and 50% 2M-GPIb (n = 41) showing quantitative and qualitative multimeric loss, that was not detected with in-house method. We were able to use established PRIs, with 73% validity in type 2 cases, to distinguish individual type 2A subtypes (IIA, IIC, IID, IIE) from 2M and 2B. Conclusion: H5/11VWM could be used for all clinical purposes because its reliability and its rapid and accurate diagnostic ability and reduced observer bias. Although H5/11VWM cannot evaluate triplet structures, we were able to define 2A subtypes by stripping back to the percentage of intermediate/high-molecular-weight multimers. H5/11HWM could be an efficient and widely available alternative for the "gold standard" technique.
引用
收藏
页码:1024 / 1034
页数:11
相关论文
共 39 条
[1]   Evaluation of a semi-automated von Willebrand factor multimer assay, the Hydragel 5 von Willebrand multimer, by two European Centers [J].
Bowyer, Annette E. ;
Goodfellow, Karen J. ;
Seidel, Holger ;
Westhofen, Philipp ;
Stufano, Francesca ;
Goodeve, Anne ;
Kitchen, Stephen ;
Makris, Michael .
RESEARCH AND PRACTICE IN THROMBOSIS AND HAEMOSTASIS, 2018, 2 (04) :790-799
[2]  
BUDDE U, 1990, THROMB HAEMOSTASIS, V63, P312
[3]   Type 2M von Willebrand disease variant characterized by abnormal von Willebrand factor multimerization [J].
Casonato, A ;
Pontara, E ;
Sartorello, F ;
Bertomoro, A ;
Durante, C ;
Girolami, A .
JOURNAL OF LABORATORY AND CLINICAL MEDICINE, 2001, 137 (01) :70-76
[4]   Type 2B von Willebrand disease with or without large multimers: A distinction of the two sides of the disorder is long overdue [J].
Casonato, Alessandra ;
Daidone, Viviana ;
Galletta, Eva ;
Bertomoro, Antonella .
PLOS ONE, 2017, 12 (06)
[5]   von Willebrand Factor Assay Proficiency Testing The North American Specialized Coagulation Laboratory Association Experience [J].
Chandler, Wayne L. ;
Peerschke, Ellinor I. B. ;
Castellone, Donna D. ;
Meijer, Piet .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2011, 135 (06) :862-869
[6]   Thrombotic Microangiopathies, Thrombotic Thrombocytopenic Purpura, and ADAMTS-13 [J].
Chapman, Kent ;
Seldon, Michael ;
Richards, Ross .
SEMINARS IN THROMBOSIS AND HEMOSTASIS, 2012, 38 (01) :47-54
[7]   Unraveling the scissile bond: how ADAMTS13 recognizes and cleaves von Willebrand factor [J].
Crawley, James T. B. ;
de Groot, Rens ;
Xiang, Yaozu ;
Luken, Brenda M. ;
Lane, David A. .
BLOOD, 2011, 118 (12) :3212-3221
[8]   Evaluation of a new commercial method for von Willebrand factor multimeric analysis [J].
Crist, R. A. ;
Heikal, N. M. ;
Rodgers, G. M. ;
Grenache, D. G. ;
Smock, K. J. .
INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2018, 40 (05) :586-591
[9]   Clinical and laboratory phenotype variability in type 2M von Willebrand disease [J].
Doruelo, A. L. ;
Haberichter, S. L. ;
Christopherson, P. A. ;
Boggio, L. N. ;
Gupta, S. ;
Lentz, S. R. ;
Shapiro, A. D. ;
Montgomery, R. R. ;
Flood, V. H. .
JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2017, 15 (08) :1559-1566
[10]   Evaluation of a new commercial von Willebrand factor multimer assay [J].
Favaloro, E. J. ;
Oliver, S. .
HAEMOPHILIA, 2017, 23 (04) :E373-E377