Analysis and discussion on the principle and application of FGD technology in coal-fired power plant

被引:0
作者
Yang, DW [1 ]
Zhu, ZP [1 ]
Yang, PC [1 ]
机构
[1] Changsha Univ Elect Power, Dept Chem, Changsha 410077, Peoples R China
来源
ENERGY & ENVIRONMENT - A WORLD OF CHALLENGES AND OPPORTUNITIES, PROCEEDINGS | 2003年
关键词
sulfur dioxide(SO2); flue gas desulfurization(FGD); thermal power plant;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In this paper the situation of SO2 discharge and pollution in Chinese coal-fired power plants is briefly introduced, and it is described the advantage and disadvantage of eight kinds of flue gas desulfurization (FGD) method used in coal-fired power plants. Especially an economic FGD method which is called Wet limestone desulfurization and dust-removal facility (simply called PXJ)is discussed carefully. Its desulfurization principle,operational parameters,technological process are given in the paper. A 2 x 125MW power plant is illustrated as an example for this FGD method. Its investment is only one-tenth of imported FGD, its operational cost is only one-third of imported FGD, and its desulfurization efficiency is over 80%.
引用
收藏
页码:651 / 654
页数:4
相关论文
共 4 条
[1]  
GUO J, 2001, ATMOSPHERE POLLUTION, P37
[2]  
HAO JM, 2001, SULFUR DIOXIDE CONTR, P17
[3]  
Wang XD, 2000, NES NUTR WS, V4, P39
[4]  
WANG ZZ, 2002, ELECT CSEEI, V1, P23