Hyperpolarized 3Helium gas for functional magnetic resonance imaging of the lung

被引:6
作者
Heussel, CP
Gast, KK
Dahmen, A
Morbach, AE
Kauczor, HU
Schreiber, WG
Thelen, M
van Beek, EJR
机构
[1] Johannes Gutenberg Univ Mainz, Klin & Poliklin Radiol, D-55131 Mainz, Germany
[2] Deutsch Krebsforschungszentrum, D-6900 Heidelberg, Germany
[3] Univ Iowa Hosp & Clin, Carver Coll Med, Dept Radiol, Iowa City, IA 52242 USA
关键词
lung diseases; pulmonary function; hyperpolarized helium-3; magnetic resonance imaging (MRI);
D O I
10.1007/s00063-005-1048-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Lung imaging is traditionally done using X-ray-based methods, since MRI is limited by low proton density as well as inherent magnetic field inhomogeneities of the lung tissue. After introduction of MRI using hyperpolarized noble gases, a totally new field of MRI of the chest has rapidly evolved. These techniques reveal new functional information of the lungs, which could not be obtained before. The first part of this review describes the underlying MR technology explaining distribution of static ventilation, dynamic distribution of ventilation lung microstructure (apparent diffusion coefficient [ADC]), measurement of oxygen partial pressure (pO(2)), and safety. The clinical potential is afterwards demonstrated in the second part. Therefore, the effort in normal lungs and the mainly focused diseases chronic obstructive pulmonary disease (COPD), smoker's lung, cystic fibrosis, asthma, lung transplantation, and pulmonary embolism are reported.
引用
收藏
页码:413 / 424
页数:12
相关论文
共 110 条
[81]   Emphysema: Hyperpolarized helium 3 diffusion MR imaging of the lungs compared with spirometric indexes - Initial experience [J].
Salerno, M ;
de Lange, EE ;
Altes, TA ;
Truwit, JD ;
Brookeman, JR ;
Mugler, JP .
RADIOLOGY, 2002, 222 (01) :252-260
[82]  
Salerno M, 2001, RADIOLOGY, V221, P631
[83]   Dynamic spiral MRI of pulmonary gas flow using hyperpolarized 3He:: Preliminary studies in healthy and diseased lungs [J].
Salerno, M ;
Altes, TA ;
Brookeman, JR ;
de Lange, EE ;
Mugler, JP .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (04) :667-677
[84]  
SALERNO M, 2002, P 10 ANN M ISMRM HON
[85]  
SALERNO M, 2003, P 89 SCI ASS ANN M R, P526
[86]   Imaging the lungs in asthmatic patients by using hyperpolarized helium-3 magnetic resonance: Assessment of response to methacholine and exercise challenge [J].
Samee, S ;
Altes, T ;
Powers, P ;
de Lange, EE ;
Knight-Scott, J ;
Rakes, G ;
Mugler, JP ;
Ciambotti, JM ;
Alford, BA ;
Brookeman, JR ;
Platts-Mills, TAE .
JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 2003, 111 (06) :1205-1211
[87]   Ultrafast MR-imaging of lung ventilation using hyperpolarized helium-3. [J].
Schreiber, WG ;
Weiler, N ;
Kauczor, HU ;
Markstaller, K ;
Eberle, B ;
Hast, J ;
Surkau, R ;
Grossmann, T ;
Deninger, A ;
Hanisch, G ;
Otten, EW ;
Thelen, M .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2000, 172 (02) :129-133
[88]  
SCHREIBER WG, 2002, INT WORKSH POL BEAMS
[89]  
SCHREIBER WG, 1999, P 7 ANN M ISMRM PHIL
[90]  
SCHREIBER WG, 2005, IN PRESS RESPIR PHYS