摘要
Objective.This study was performed to test the hypothesis that temporary renal ischemia will result in increased thermal lesion size during radiofrequency thermal ablation in the kidney. Materials and methods. Twelve kidneys were treated in six pigs that were placed under general anesthesia in the MR suite, using a 0.2-T open C-shaped MR imaging system. A 4-cm-long, 14-mm-diameter balloon catheter was placed into the aorta using a transfemoral approach, and the balloon was positioned proximal to the renal arteries via guidance with MR imaging. A 2-cm exposed-tip MR-compatible 17-gauge radiofrequency electrode was placed into one kidney under MR fluoroscopy using fast imaging with steady-state free precession (FISP) sequences. Thermal ablation was performed with the electrode tip temperature maintained at 90 +/- 2 degreesC for 10 min. This procedure was repeated in the contralateral kidney. The balloon was inflated during one ablation. Postablation images were obtained, the pigs were sacrificed, and both kidneys of each animal were harvested for pathologic correlation. Results. Technical success was achieved in all animals. The lesion measured 14.2 +/- 2.2 mm (mean +/- standard deviation) for the ischemic kidney versus 8.0 +/- 2.6 mm in the normally perfused kidney (p = 0.00002). No significant complications were noted. In all images, thermal lesions displayed low signal intensity with a sharp rim of high signal intensity best visualized using short tau inversion recovery (STIR) sequences with a mean accuracy of 1.3 +/- 1.2 mm when compared with pathologic findings and a mean contrast-to-noise ratio of 4.9 +/- 2.5. Conclusion. We accept the hypothesis that temporary renal ischemia leads to a significantly increased radiofrequency ablation lesion size. We conclude that catheter-based balloon perfusion reduction is feasible, that the procedure does nor lead to major complications, and that it can be performed using MR imaging as the sole imaging modality.
引用
收藏
页码:151 / 158
页数:8
相关论文
共 50 条
  • [11] MR-guided RF thermal ablation of the kidney in a porcine model
    Merkle, EM
    Shonk, JR
    Duerk, JL
    Jacobs, GH
    Lewin, JS
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 173 (03) : 645 - 651
  • [12] Percutaneous MR imaging-guided radiofrequency interstitial thermal ablation of tongue base in porcine models: Implications for obstructive sleep apnea syndrome
    Nour, SG
    Lewin, JS
    Gutman, M
    Hillenbrand, C
    Wacker, FK
    Wong, JW
    Mitchell, IC
    Armstrong, CB
    Hashim, MM
    Duerk, JL
    Strauss, M
    RADIOLOGY, 2004, 230 (02) : 359 - 368
  • [13] MR imaging-guided radio-frequency thermal ablation of the lumbar vertebrae in porcine models
    Nour, SG
    Aschoff, AJ
    Mitchell, ICS
    Emancipator, SN
    Duerk, JL
    Lewin, JS
    RADIOLOGY, 2002, 224 (02) : 452 - 462
  • [14] Phase II clinical trial of interactive MR imaging-guided interstitial radiofrequency thermal ablation of primary kidney tumors: Initial experience
    Lewin, JS
    Nour, SG
    Connell, CF
    Sulman, A
    Duerk, JL
    Resnick, MI
    Haaga, JR
    RADIOLOGY, 2004, 232 (03) : 835 - 845
  • [15] Dual-Applicator MR Imaging-Guided Microwave Ablation with Real-Time MR Thermometry: Phantom and Porcine Tissue Model Experiments
    Ren, Liqiang
    Woodrum, David A.
    Gorny, Krzysztof R.
    Felmlee, Joel P.
    Favazza, Christopher P.
    Thompson, Scott M.
    Lu, Aiming
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2023, 34 (01) : 46 - 53.e4
  • [16] MR Imaging-Guided Laser Ablation of Hepatic and Renal Tumors
    Giesbrandt, K.
    Walser, E.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 198 (05)
  • [17] FOCUSED US SYSTEM FOR MR IMAGING-GUIDED TUMOR ABLATION
    CLINE, HE
    HYNYNEN, K
    WATKINS, RD
    ADAMS, WJ
    SCHENCK, JF
    ETTINGER, RH
    FREUND, WR
    VETRO, JP
    JOLESZ, FA
    RADIOLOGY, 1995, 194 (03) : 731 - 737
  • [18] CT and MR imaging after imaging-guided thermal ablation of renal neoplasms
    Wile, Geoffrey E.
    Leyendecker, John R.
    Krehbiel, Kyle A.
    Dyer, Raymond B.
    Zagoria, Ronald J.
    RADIOGRAPHICS, 2007, 27 (02) : 325 - U42
  • [19] MR imaging-guided radio-frequency thermal ablation in the pancreas in a porcine model with a modified clinical C-arm system
    Merkle, EM
    Haaga, JR
    Duerk, JL
    Jacobs, GH
    Brambs, HJ
    Lewin, JS
    RADIOLOGY, 1999, 213 (02) : 461 - 467
  • [20] MR imaging-guided interventions
    Kahn, T
    Schmidt, F
    Mödder, U
    RADIOLOGE, 1999, 39 (09): : 741 - 749