Perfusion-modulated MR imaging-guided radiofrequency ablation of the kidney in a porcine model

被引:31
|
作者
Aschoff, AJ
Sulman, A
Martinez, M
Duerk, JL
Resnick, MI
MacLennan, GT
Lewin, JS
机构
[1] Case Western Reserve Univ, Univ Hosp Cleveland, Dept Radiol, Div MR Imaging, Cleveland, OH 44106 USA
[2] Univ Ulm, Dept Diagnost Radiol, D-89075 Ulm, Germany
[3] Case Western Reserve Univ, Univ Hosp Cleveland, Dept Urol, Cleveland, OH 44106 USA
[4] Case Western Reserve Univ, Dept Biomed Engn, Cleveland, OH 44106 USA
[5] Case Western Reserve Univ, Univ Hosp Cleveland, Dept Pathol, Cleveland, OH 44106 USA
[6] Case Western Reserve Univ, Univ Hosp Cleveland, Dept Oncol, Cleveland, OH 44106 USA
关键词
D O I
10.2214/ajr.177.1.1770151
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective.This study was performed to test the hypothesis that temporary renal ischemia will result in increased thermal lesion size during radiofrequency thermal ablation in the kidney. Materials and methods. Twelve kidneys were treated in six pigs that were placed under general anesthesia in the MR suite, using a 0.2-T open C-shaped MR imaging system. A 4-cm-long, 14-mm-diameter balloon catheter was placed into the aorta using a transfemoral approach, and the balloon was positioned proximal to the renal arteries via guidance with MR imaging. A 2-cm exposed-tip MR-compatible 17-gauge radiofrequency electrode was placed into one kidney under MR fluoroscopy using fast imaging with steady-state free precession (FISP) sequences. Thermal ablation was performed with the electrode tip temperature maintained at 90 +/- 2 degreesC for 10 min. This procedure was repeated in the contralateral kidney. The balloon was inflated during one ablation. Postablation images were obtained, the pigs were sacrificed, and both kidneys of each animal were harvested for pathologic correlation. Results. Technical success was achieved in all animals. The lesion measured 14.2 +/- 2.2 mm (mean +/- standard deviation) for the ischemic kidney versus 8.0 +/- 2.6 mm in the normally perfused kidney (p = 0.00002). No significant complications were noted. In all images, thermal lesions displayed low signal intensity with a sharp rim of high signal intensity best visualized using short tau inversion recovery (STIR) sequences with a mean accuracy of 1.3 +/- 1.2 mm when compared with pathologic findings and a mean contrast-to-noise ratio of 4.9 +/- 2.5. Conclusion. We accept the hypothesis that temporary renal ischemia leads to a significantly increased radiofrequency ablation lesion size. We conclude that catheter-based balloon perfusion reduction is feasible, that the procedure does nor lead to major complications, and that it can be performed using MR imaging as the sole imaging modality.
引用
收藏
页码:151 / 158
页数:8
相关论文
共 50 条
  • [1] MR imaging-guided radiofrequency thermal ablation in the porcine brain at 0.2 T
    Merkle, EM
    Shonk, JR
    Zheng, L
    Duerk, JL
    Lewin, JS
    EUROPEAN RADIOLOGY, 2001, 11 (05) : 884 - 892
  • [2] MR imaging-guided radiofrequency thermal ablation in the porcine brain at 0.2 T
    Elmar M. Merkle
    Jason R. Shonk
    L. Zheng
    Jeffrey L. Duerk
    Jonathan S. Lewin
    European Radiology, 2001, 11 : 884 - 892
  • [3] MR imaging-guided radiofrequency thermal ablation in the porcine brain at 0.2T
    Merkle, EM
    Shonk, JR
    Zheng, L
    Duerk, JL
    Lewin, JS
    RADIOLOGY, 1999, 213P : 359 - 359
  • [4] MR imaging-guided radiofrequency thermal ablation of the pancreas in a porcine model with a modified clinical C-arm system
    Merkle, EM
    Haaga, JR
    Duerk, JL
    Brambs, H
    Lewin, JS
    RADIOLOGY, 1998, 209P : 448 - 448
  • [5] Perfusion modulated MRI-guided radiofreqency (RF) ablation of the kidney in a porcine model
    Aschoff, AJ
    Sulman, A
    Resnick, M
    Duerk, JL
    Lewin, JS
    RADIOLOGY, 2000, 217 : 533 - 533
  • [6] Femur: MR imaging-guided radio-frequency ablation in porcine model - Feasibility study
    Aschoff, AJ
    Merkle, EM
    Emancipator, SN
    Petersilge, CA
    Duerk, JL
    Lewin, JS
    RADIOLOGY, 2002, 225 (02) : 471 - 478
  • [7] Imaging-guided radiofrequency ablation of renal masses
    Zagoria, RJ
    RADIOGRAPHICS, 2004, 24 : S59 - S71
  • [8] MR imaging-guided percutaneous tumor ablation
    Silverman, SG
    Tuncali, K
    Morrison, PR
    ACADEMIC RADIOLOGY, 2005, 12 (09) : 1100 - 1109
  • [9] Imaging-Guided Radiofrequency Ablation of Cystic Renal Neoplasms
    Allen, Brian C.
    Chen, Michael Y.
    Childs, David D.
    Zagoria, Ronald J.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 200 (06) : 1365 - 1369
  • [10] Imaging-guided radiofrequency ablation of solid renal tumors
    Farrell, MA
    Charboneau, WJ
    DiMarco, DS
    Chow, GK
    Zincke, H
    Callstrom, MR
    Lewis, BD
    Lee, RA
    Reading, CC
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2003, 180 (06) : 1509 - 1513