No News is Good News: Remote Monitoring of Implantable Cardioverter-Defibrillator Patients

被引:18
作者
Skov, Mikael B. [1 ]
Johansen, Pauline G. [2 ]
Skov, Charlotte S. [2 ]
Lauberg, Astrid [2 ]
机构
[1] Aalborg Univ, Ctr Sociointeract Design, Dept Comp Sci, Selma Lagerlofs Vej 300, DK-9220 Aalborg, Denmark
[2] Aalborg Univ Hosp, Ctr Cardiovasc Res, Dept Cardiol, DK-9000 Aalborg, Denmark
来源
CHI 2015: PROCEEDINGS OF THE 33RD ANNUAL CHI CONFERENCE ON HUMAN FACTORS IN COMPUTING SYSTEMS | 2015年
关键词
Remote monitoring; implantable cardioverter defibrillator; ICD; surveillance; privacy; anxiety;
D O I
10.1145/2702123.2702192
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
Implantable cardioverter-defibrillator (ICD) patients have increased safety when connected to remote monitoring as ICD problems and issues are instantly discovered compared to patients without a monitor. While remote monitoring is intrusive in the domestic environment, little HCI research has investigated how people live and interact with such monitoring technologies. We conducted a study with 19 ICD patients and their spouses using diaries and interviews. Our findings illustrate that our participants were satisfied with the monitoring despite the fact that they had almost no knowledge of the data collected and they lacked feedback from the monitor on transmission and operation. Based on our findings, we describe a safety paradox for remote monitoring as participants experienced less safety while being safer, and identify privacy and surveillance concerns in the unequal monitoring of ICD patients.
引用
收藏
页码:827 / 836
页数:10
相关论文
共 31 条
[1]   Remote Monitoring of Implantable Cardioverter Defibrillators versus Quarterly Device Interrogations in Clinic: Results from a Randomized Pilot Clinical Trial [J].
Al-Khatib, Sana M. ;
Piccini, Jonathan P. ;
Knight, David ;
Stewart, Margaret ;
Clapp-Channing, Nancy ;
Sanders, Gillian D. .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2010, 21 (05) :545-550
[2]  
[Anonymous], GUID GOOD CLIN PRACT
[3]  
[Anonymous], P UBICOMP 13
[4]  
[Anonymous], 2005, P SIGCHI C HUMAN FAC, DOI DOI 10.1145/1054972.1055098
[5]  
Ballegaard SA, 2008, CHI 2008: 26TH ANNUAL CHI CONFERENCE ON HUMAN FACTORS IN COMPUTING SYSTEMS VOLS 1 AND 2, CONFERENCE PROCEEDINGS, P1807
[6]  
Birnholtz J, 2010, CHI2010: PROCEEDINGS OF THE 28TH ANNUAL CHI CONFERENCE ON HUMAN FACTORS IN COMPUTING SYSTEMS, VOLS 1-4, P143
[7]   What evidence do we have to replace in-hospital implantable cardioverter clefibrillator follow-up? [J].
Brugada, P .
CLINICAL RESEARCH IN CARDIOLOGY, 2006, 95 (Suppl 3) :3-9
[8]   Remote monitoring and follow-up of pacemakers and implantable cardioverter defibrillators [J].
Burri, Haran ;
Senouf, David .
EUROPACE, 2009, 11 (06) :701-709
[9]  
Choe EK, 2011, UBICOMP'11: PROCEEDINGS OF THE 2011 ACM INTERNATIONAL CONFERENCE ON UBIQUITOUS COMPUTING, P41
[10]  
Denning T, 2010, CHI2010: PROCEEDINGS OF THE 28TH ANNUAL CHI CONFERENCE ON HUMAN FACTORS IN COMPUTING SYSTEMS, VOLS 1-4, P917