MEG-compatible pneumatic stimulator to elicit passive finger and toe movements

被引:55
作者
Piitulainen, Harri [1 ]
Bourguignon, Mathieu
Hari, Riitta
Jousmaki, Veikko
机构
[1] Aalto Univ, Sch Sci, Aalto NeuroImaging, Dept Neurosci & Biomed Engn,Brain Res Unit, Espoo 00076, Finland
基金
欧洲研究理事会; 芬兰科学院;
关键词
Corticokinematic coherence; Motor mapping; Accelerometer; Kinematics; Magnetoencephalography; Sensorimotor cortex; Pneumatic muscle; EVOKED MAGNETIC-FIELDS; MAGNETOENCEPHALOGRAPHY; COHERENCE; VOLUNTARY; VIBRATION;
D O I
10.1016/j.neuroimage.2015.03.006
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Magnetoencephalographic (MEG) signals recorded from the primary sensorimotor (SM1) cortex are coherent with kinematics of both active and passive finger movements. The coherence mainly reflects movement-related proprioceptive afference to the cortex. Here we describe a novel MEG-compatible stimulator to generate computer-controlled passive finger and toe movements that can be used as stimuli in functional brain-imaging experiments. The movements are produced by pneumatic artificial muscle (PAM), elastic actuator that shortens with increasing air pressure. To test the applicability of the stimulator to functional brain-imaging, 4-min trains of passive repetitive 5-mm flexion-extension movements of the right and left index finger and the right hallux were produced at 3 Hz while the subject's brain activity was measured with whole-scalp MEG and finger or toe kinematics with an accelerometer. In all ten subjects studied, statistically significant coherence (up to 0.78) occurred between the accelerometer and MEG signals at the movement frequency or its first harmonic. Sources of coherent activity were in the contralateral hand or foot SM1 cortices. Movement-evoked fields elicited with intermittent movements of the right index finger (once every 3.2-4.0 s; mean +/- SD peak response latency 88 +/- 25 ms) were co-located with the respective coherent sources. We further moved the right index finger at 3, 6, and 12 Hz (movement ranges 5, 3, and 2mm, respectively), and analyzed the first 1, 2, and 4-min epochs of data. One minute of data was sufficient to locate the left hand area of the SM1 cortex at all movement frequencies. Sound-induced spurious coherence was reliably ruled out in a control experiment. Our novel movement stimulator thus provides a robust and reliable tool to track proprioceptive afference to the cortex and to locate the SM1 cortex. (C) 2015 The Authors. Published by Elsevier Inc.
引用
收藏
页码:310 / 317
页数:8
相关论文
共 29 条
[1]   Cortical activation associated with passive movements of the human index finger:: An MEG study [J].
Alary, F ;
Simoes, C ;
Jousmäki, V ;
Forss, N ;
Hari, R .
NEUROIMAGE, 2002, 15 (03) :691-696
[2]   Approximation of statistical distribution of magnitude squared coherence estimated with segment overlapping [J].
Bortel, Radoslav ;
Sovka, Pavel .
SIGNAL PROCESSING, 2007, 87 (05) :1100-1117
[3]   Corticokinematic coherence mainly reflects movement-induced proprioceptive feedback [J].
Bourguignon, Mathieu ;
Piitulainen, Harri ;
De Tiege, Xavier ;
Jousmaki, Veikko ;
Hari, Riitta .
NEUROIMAGE, 2015, 106 :382-390
[4]   Comprehensive Functional Mapping Scheme for Non-Invasive Primary Sensorimotor Cortex Mapping [J].
Bourguignon, Mathieu ;
Jousmaki, Veikko ;
Marty, Brice ;
Wens, Vincent ;
Op de Beeck, Marc ;
Van Bogaert, Patrick ;
Nouali, Mustapha ;
Metens, Thierry ;
Lubicz, Boris ;
Lefranc, Florence ;
Bruneau, Michael ;
De Witte, Olivier ;
Goldman, Serge ;
De Tiege, Xavier .
BRAIN TOPOGRAPHY, 2013, 26 (03) :511-523
[5]   Neuronal network coherent with hand kinematics during fast repetitive hand movements [J].
Bourguignon, Mathieu ;
Jousmaki, Veikko ;
de Beeck, Marc Op ;
Van Bogaert, Patrick ;
Goldman, Serge ;
De Tiege, Xavier .
NEUROIMAGE, 2012, 59 (02) :1684-1691
[6]   Functional motor-cortex mapping using corticokinematic coherence [J].
Bourguignon, Mathieu ;
De Tiege, Xavier ;
de Beeck, Marc Op ;
Pirotte, Benoit ;
Van Bogaert, Patrick ;
Goldman, Serge ;
Hari, Riitta ;
Jousmaki, Veikko .
NEUROIMAGE, 2011, 55 (04) :1475-1479
[7]   Detection of vibration transmitted through an object grasped in the hand [J].
Brisben, AJ ;
Hsiao, SS ;
Johnson, KO .
JOURNAL OF NEUROPHYSIOLOGY, 1999, 81 (04) :1548-1558
[8]   RELATIVE SENSITIVITY TO VIBRATION OF MUSCLE RECEPTORS OF CAT [J].
BROWN, MC ;
ENGBERG, I ;
MATTHEWS, PB .
JOURNAL OF PHYSIOLOGY-LONDON, 1967, 192 (03) :773-&
[9]   Sensory feedback contributes to early movement-evoked fields during voluntary finger movements in humans [J].
Cheyne, D ;
Endo, H ;
Takeda, T ;
Weinberg, H .
BRAIN RESEARCH, 1997, 771 (02) :196-202
[10]   SEPS TO FINGER JOINT INPUT LACK THE N20-P20 RESPONSE THAT IS EVOKED BY TACTILE INPUTS - CONTRAST BETWEEN CORTICAL GENERATORS IN AREA-3B AND AREA-2 IN HUMANS [J].
DESMEDT, JE ;
OZAKI, I .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1991, 80 (06) :513-521