High Frame Rate Volumetric Imaging of Microbubbles Using a Sparse Array and Spatial Coherence Beamforming

被引:18
|
作者
Wei, Luxi [1 ]
Wahyulaksana, Geraldi [1 ]
Meijlink, Bram [1 ]
Ramalli, Alessandro [2 ]
Noothout, Emile [3 ]
Verweij, Martin D. [3 ]
Boni, Enrico [2 ]
Kooiman, Klazina [1 ]
van der Steen, Antonius F. W. [1 ]
Tortoli, Piero [2 ]
de Jong, Nico [1 ,3 ]
Vos, Hendrik J. [1 ,3 ]
机构
[1] Erasmus MC, Dept Cardiol, Univ Med Ctr Rotterdam, NL-3015 CN Rotterdam, Netherlands
[2] Univ Florence, Dept Informat Engn, I-50139 Florence, Italy
[3] Delft Univ Technol, ImPhys, NL-2628 CJ Delft, Netherlands
基金
荷兰研究理事会;
关键词
Imaging; Array signal processing; Spatial coherence; Clutter; Ultrasonic imaging; Spirals; Signal to noise ratio; Coherence beamforming; high frame rate; microbubbles; sparse array; volumetric imaging; ULTRASOUND; DOPPLER; RECOMMENDATIONS;
D O I
10.1109/TUFFC.2021.3086597
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Volumetric ultrasound imaging of blood flow with microbubbles enables a more complete visualization of the microvasculature. Sparse arrays are ideal candidates to perform volumetric imaging at reduced manufacturing complexity and cable count. However, due to the small number of transducer elements, sparse arrays often come with high clutter levels, especially when wide beams are transmitted to increase the frame rate. In this study, we demonstrate with a prototype sparse array probe and a diverging wave transmission strategy, that a uniform transmission field can be achieved. With the implementation of a spatial coherence beamformer, the background clutter signal can be effectively suppressed, leading to a signal to background ratio improvement of 25 dB. With this approach, we demonstrate the volumetric visualization of single microbubbles in a tissue-mimicking phantom as well as vasculature mapping in a live chicken embryo chorioallantoic membrane.
引用
收藏
页码:3069 / 3081
页数:13
相关论文
共 50 条
  • [41] Adaptive Beamforming Algorithm for Ultrasonic Array with the Combination of Spatial Sampling and Coherence Factor
    Song S.
    Li Q.
    Gongcheng Kexue Yu Jishu/Advanced Engineering Sciences, 2021, 53 (04): : 200 - 208
  • [42] Mitigating skin tone bias in linear array in vivo photoacoustic imaging with short-lag spatial coherence beamforming
    Fernandes, Guilherme S. P.
    Uliana, Joao H.
    Bachmann, Luciano
    Carneiro, Antonio A. O.
    Bell, Muyinatu A. Lediju
    Pavan, Theo Z.
    PHOTOACOUSTICS, 2023, 33
  • [43] High Frame Rate Vector Flow Imaging with a Convex Array in a simulated vessel phantom
    Ghigo, Nina
    Perrot, Vincent
    Harbaoui, Brahim
    Long, Anne
    Ricci, Stefano
    Tortoli, Piero
    Vray, Didier
    Liebgott, Herve
    2019 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2019, : 356 - 359
  • [44] An Encoded Photodetector Array for High-Frame-Rate Compressed Sensing and Computational Imaging
    Pan, Wen
    Yang, Zhaolong
    Hao, Zhibiao
    Sun, Changzheng
    Xiong, Bing
    Wang, Jian
    Han, Yanjun
    Li, Hongtao
    Gan, Lin
    Luo, Yi
    Wang, Lai
    IEEE SENSORS JOURNAL, 2025, 25 (02) : 2574 - 2582
  • [45] A High-Frequency, High Frame Rate Duplex Ultrasound Linear Array Imaging System for Small Animal Imaging
    Zhang, Lequan
    Xu, Xiaochen
    Hu, Changhong
    Sun, Lei
    Yen, Jesse T.
    Cannata, Jonathan M.
    Shung, K. Kirk
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2010, 57 (07) : 1548 - 1557
  • [46] Development and characterization of a sparse ellipsoidal 256 element array for volumetric ultrasound imaging
    Fournelle, Marc
    Degel, Christian
    Jakob, Anette
    Nooijens, Sjoerd
    Weber, Steffen
    D'hooge, Jan
    Tretbar, Steffen
    INTERNATIONAL ULTRASONICS SYMPOSIUM (IEEE IUS 2021), 2021,
  • [47] Improved high-frequency high frame rate duplex ultrasound linear array imaging system
    Zhang, Lequan
    Xu, Xiaochen
    Hu, Changhong
    Sun, Lei
    Yen, Jesse T.
    Cannata, Jonathan M.
    Shung, K. Kirk
    2008 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-4 AND APPENDIX, 2008, : 1730 - +
  • [48] Cavitation Monitoring and Passive Beamforming Using a Hemispherical Random Sparse Array
    O'Reilly, Meaghan A.
    Rahman, Sami
    Hynynen, Kullervo
    11TH INTERNATIONAL SYMPOSIUM ON THERAPEUTIC ULTRASOUND, 2012, 1481 : 271 - 275
  • [50] Towed array beamforming using sparse Bayesian learning during maneuvering
    Zheng, Zheng
    Yang, T. C.
    Pan, Xiang
    Gerstoft, Peter
    OCEANS 2019 - MARSEILLE, 2019,