A fixed-bed column for phosphate removal from aqueous solutions using an andosol-bagasse mixture

被引:49
|
作者
Woumfo, Emmanuel Djoufac [1 ]
Siewe, Jean Mermoz [1 ]
Njopwouo, Daniel [1 ]
机构
[1] Univ Yaounde I, Fac Sci, Dept Chim Inorgan, Lab Phys Chim Mat Mineraux, BP 812, Yaounde, Cameroon
关键词
Phosphate; Fixed-bed; Adsorption; Andosol; Breakthrough; METHYLENE-BLUE; IRON-OXIDE; ADSORPTION CHARACTERISTICS; HEXAVALENT CHROMIUM; LEAF POWDER; KINETICS; MONTMORILLONITE; PHOSPHORUS; DESORPTION; KAOLINITE;
D O I
10.1016/j.jenvman.2014.11.029
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
It is difficult to eliminate phosphate from large volumes of water in batch mode using an adsorbent such as andosol. In a fixed-bed column, andosol has a very low permeability. In this study, andosol was mixed with bagasse to increase permeability. The mixture was then applied for the adsorption of phosphate in a fixed-bed column. Optimum and stable permeability was obtained with a 50/50 mixture of andosol and bagasse. The maximum adsorption capacity obtained was 4.18 mg/g for a column with a bed depth of 1.8 cm and a flow rate of 4 mL/min. The experimental data fit best to Thomas and Adam-Bohart models. These experimental results were applied in the treatment of natural phosphate-containing water from Yaounde Municipal Lake in Cameroon. Column performance increased by 60% due to the presence of Ca2+ and Mg2+ in the natural water. These cations form complexes with phosphate at the andosol surface. The standard enthalpy 15.964 kj/mol indicated that phosphate adsorption on andosol-bagasse mixture was an endothermic process. Kinetic experiments demonstrated that phosphate adsorption fitted better with a pseudo-second-order model. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:450 / 460
页数:11
相关论文
共 50 条
  • [1] Removal of Atenolol and Isoproturon in Aqueous Solutions by Adsorption in a Fixed-Bed Column
    Luis Sotelo, Jose
    Ovejero, Gabriel
    Rodriguez, Araceli
    Alvarez, Silvia
    Garcia, Juan
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2012, 51 (13) : 5045 - 5055
  • [2] Phosphate removal from water using a hybrid material in a fixed-bed column
    Ramirez, A.
    Giraldo, S.
    Garcia-Nunez, J.
    Florez, E.
    Acelas, N.
    JOURNAL OF WATER PROCESS ENGINEERING, 2018, 26 : 131 - 137
  • [3] Removal of Denim Blue from Aqueous Solutions by Inorganic Adsorbents in a Fixed-Bed Column
    Gutierrez-Segura, E.
    Colin-Cruz, A.
    Solache-Rios, M.
    Fall, C.
    WATER AIR AND SOIL POLLUTION, 2012, 223 (08): : 5505 - 5513
  • [4] Removal of Denim Blue from Aqueous Solutions by Inorganic Adsorbents in a Fixed-Bed Column
    E. Gutiérrez-Segura
    A. Colín-Cruz
    M. Solache-Ríos
    C. Fall
    Water, Air, & Soil Pollution, 2012, 223 : 5505 - 5513
  • [5] Fixed-Bed Column Technique for the Removal of Phosphate from Water Using Leftover Coal
    Mekonnen, Dereje Tadesse
    Alemayehu, Esayas
    Lennartz, Bernd
    MATERIALS, 2021, 14 (19)
  • [6] Ammonium removal from aqueous solutions by fixed-bed column using corncob-based modified biochar
    Lan Huong Nguyen
    Thi Mai Vu
    Thi Trinh Le
    Van Tuyen Trinh
    Thi Pha Tran
    Huu Tap Van
    ENVIRONMENTAL TECHNOLOGY, 2019, 40 (06) : 683 - 692
  • [7] Removal of basic dyes from aqueous environment in single and binary systems by sugarcane bagasse in a fixed-bed column
    Khoo, Eng-Cheong
    Ong, Siew-Teng
    Ha, Sie-Tiong
    DESALINATION AND WATER TREATMENT, 2012, 37 (1-3) : 215 - 222
  • [8] Removal of Ni(II) ions from aqueous solutions using fixed-bed ion exchange column technique
    Shaidan, Nur Hamizah
    Eldemerdash, Usama
    Awad, Sherine
    JOURNAL OF THE TAIWAN INSTITUTE OF CHEMICAL ENGINEERS, 2012, 43 (01) : 40 - 45
  • [9] Removal of methylene blue from aqueous solutions by straw based adsorbent in a fixed-bed column
    Zhang, Wenxuan
    Dong, Lei
    Yan, Han
    Li, Haijiang
    Jiang, Ziwen
    Kan, Xiaowei
    Yang, Hu
    Li, Aimin
    Cheng, Rongshi
    CHEMICAL ENGINEERING JOURNAL, 2011, 173 (02) : 429 - 436
  • [10] Adsorption of phosphate from aqueous solutions and sewage using zirconium loaded okara (ZLO): Fixed-bed column study
    Nguyen, A. H.
    Ngo, H. H.
    Guo, W. S.
    Pham, T. Q.
    Li, F. M.
    Nguyen, T. V.
    Bui, X. T.
    SCIENCE OF THE TOTAL ENVIRONMENT, 2015, 523 : 40 - 49