DEVELOPMENT OF A CLINICALLY VALIDATED BULK FAILURE TEST FOR CERAMIC CROWNS

被引:216
作者
Kelly, J. Robert [2 ]
Rungruanganunt, Patchnee [1 ]
Hunter, Ben [3 ]
Vailati, Francesca [4 ]
机构
[1] Univ Connecticut, Ctr Hlth, Dept Reconstruct Dent, Div Prosthodont, Farmington, CT 06030 USA
[2] Univ Connecticut, Ctr Hlth, Ctr Biomat, Farmington, CT 06030 USA
[3] USN, Sch Postgrad Dent, Natl Naval Med Ctr, Bethesda, MD 20084 USA
[4] Univ Geneva, Sch Dent Med, Dept Fixed Prosthodont & Occlus, Geneva, Switzerland
关键词
DENTAL CERAMICS; HUMAN-ENAMEL; PORCELAIN; RESTORATIONS; RESISTANCE; STRENGTH; FATIGUE; DAMAGE; FEA;
D O I
10.1016/S0022-3913(10)60129-1
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Traditional testing of ceramic crowns creates a stress state and damage modes that differ greatly from those seen clinically. There is a need OD develop and communicate an in vitro testing protocol that is clinically valid. Purpose. The purpose of this study was to develop an in vitro failure test for ceramic single-unit prostheses that duplicates the failure mechanism and stress state observed in clinically failed prostheses. This article first compares characteristics of traditional load-to-failure tests of ceramic crowns with the growing body of evidence regarding failure origins and stress states at failure from the examination of clinically failed crowns, finite element analysis (FEA), and data from clinical studies. Based on this analysis, an experimental technique was systematically developed and test materials were identified to recreate key aspects of clinical failure in vitro. Material and methods. One potential dentin analog material (an epoxy filled with woven glass fibers; NEMA grade G10) was evaluated for elastic modulus in blunt contact and for bond strength to resin cement as compared to hydrated dentin. Two bases with different elastic moduli (nickel chrome and resin-based composite) were tested for influence on failure loads. The influence of water during storage and loading (both monotonic and cyclic) was examined. Loading piston materials (G10, aluminum, stainless steel) and piston designs were varied to eliminate Hertzian cracking and to improve performance. Testing was extended from a monolayer ceramic (leucite-filled glass) to a bilayer ceramic system (glass-infiltrated alumina). The influence of cyclic rate on mean failure loads was examined (2 Hz, 10 Hz, 20 Hz) with the extremes compared statistically (t test; alpha=.05). Results. Failure loads were highly influenced by base elastic modulus (t test; P<.001). Cyclic loading while in water significantly decreased mean failure loads (1-way ANOVA; P=.003) versus wet storage/dry cycling (350 N vs. 1270 N). G10 was not significantly different from hydrated dentin in terms of blunt contact elastic behavior or resin cement bond strength. Testing was successful with the bilayered ceramic, and the cycling rate altered mean failure loads only slightly (approximately 5%). Conclusions. Test methods and materials were developed to validly simulate many aspects of clinical failure. (J Prosthet Dent 2010;104:228-238)
引用
收藏
页码:228 / 238
页数:11
相关论文
共 31 条
[1]  
Al-Makramani Bandar M A, 2008, J Prosthodont, V17, P120, DOI 10.1111/j.1532-849X.2007.00270.x
[2]  
Al-Wahadni Ahed M, 2009, J Contemp Dent Pract, V10, P51
[3]   Laboratory Simulation of Y-TZP All-ceramic Crown Clinical Failures [J].
Coelho, P. G. ;
Bonfante, E. A. ;
Silva, N. R. F. ;
Rekow, E. D. ;
Thompson, V. P. .
JOURNAL OF DENTAL RESEARCH, 2009, 88 (04) :382-386
[4]   The influence of different core material on the FEA-determined stress distribution in dental crowns [J].
De Jager, N ;
de Kier, M ;
van der Zel, JM .
DENTAL MATERIALS, 2006, 22 (03) :234-242
[5]  
JONES DW, 1987, BRIT CERAM TRANS J, V86, P40
[6]  
Kelly J R, 1990, Int J Prosthodont, V3, P430
[7]   FRACTURE-SURFACE ANALYSIS OF DENTAL CERAMICS [J].
KELLY, JR ;
CAMPBELL, SD ;
BOWEN, HK .
JOURNAL OF PROSTHETIC DENTISTRY, 1989, 62 (05) :536-541
[8]   Clinically relevant approach to failure testing of all-ceramic restorations [J].
Kelly, JR .
JOURNAL OF PROSTHETIC DENTISTRY, 1999, 81 (06) :652-661
[9]   Sliding contact fatigue damage in layered ceramic structures [J].
Kim, J.-W. ;
Kim, J.-H. ;
Thompson, V. P. ;
Zhang, Y. .
JOURNAL OF DENTAL RESEARCH, 2007, 86 (11) :1046-ii
[10]   Hardness and Young's modulus of human peritubular and intertubular dentine [J].
Kinney, JH ;
Balooch, M ;
Marshall, SJ ;
Marshall, GW ;
Weihs, TP .
ARCHIVES OF ORAL BIOLOGY, 1996, 41 (01) :9-13