Changes in Corneal Biomechanics and Intraocular Pressure Following Cataract Surgery

被引:36
作者
Hirasawa, Kazunori [1 ,2 ,3 ,4 ,6 ]
Nakakura, Shunsuke [7 ]
Nakao, Yoshitaka [8 ]
Fujino, Yuri [1 ]
Matsuura, Masato [1 ,5 ]
Murata, Hiroshi [1 ]
Kiuchi, Yoshiaki [8 ]
Asaoka, Ryo [1 ]
机构
[1] Univ Tokyo Grad Sch Med, Dept Ophthalmol, Tokyo, Japan
[2] Moorfields Eye Hosp NHS Fdn Trust, London, England
[3] UCL, Inst Ophthalmol, London, England
[4] Kitasato Univ, Sch Med, Dept Ophthalmol, Kanagawa, Japan
[5] Kitasato Univ, Grad Sch Med Sci, Dept Ophthalmol, Kanagawa, Japan
[6] Kitasato Univ, Kanagawa, Japan
[7] Saneikai Tsukazaki Hosp, Dept Ophthalmol, Himeji, Hyogo, Japan
[8] Hiroshima Univ, Dept Ophthalmol & Visual Sci, Hiroshima, Japan
基金
日本科学技术振兴机构;
关键词
ENDOTHELIAL-CELL LOSS; RESPONSE PARAMETERS; LENS IMPLANTATION; PHACOEMULSIFICATION; THICKNESS; HYSTERESIS; EYES; MICROINCISION; ORGANIZATION; KERATOCONUS;
D O I
10.1016/j.ajo.2018.07.025
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To investigate the effects of cataract surgery on corneal biomechanics and intraocular pressure (IOP) measured with the updated Corvis ST tonometer (CST). DESIGN: Prospective, interventional case series study. METHODS: This study included 39 eyes of 39 cataract patients. CST measurements were performed at presurgery (Pre) as well as 1 week (1W), 1 month (1M), and 3 months (3M) postsurgery. The following CST parameters were recorded: deformation amplitude max (DA max), DA ratio max 1 mm and 2 mm, integrated radius, stiffness parameter at applanation 1 (SP A1), Ambrosio relational thickness to the horizontal profile (ARTh), Corvis biomechanical index (CBI), central corneal thickness (CCT), noncorrected intraocular pressure (IOPnct), and biomechanically corrected IOP (bIOP). IOP was also measured with Goldmann applanation tonometry and the noncontact tonometer CT-90A. All measurements were compared at each period using the linear mixed model, with and without adjustment for bIOP and CCT. RESULTS: All IOP measurements decreased over time (P < .01). CCT was increased at 1W and 3M (P < .01), whereas ARTh was decreased at 1W and 1M (P < .01), but returned to its Pre level at 3M. DA max and Integrated radius were increased at 3M (P < .01), whereas SP A1 was decreased at 3M (P < .01). CBI was increased at 1W (P < .01), but returned to its Pre level at 1M. CONCLUSIONS: IOP and Corneal biomechanical properties are changed after cataract surgery. In particular, SP A1 decreases while DA max and integrated radius increase, even at 3M, suggesting a less stiff cornea. (C) 2018 Elsevier Inc. All rights reserved.
引用
收藏
页码:26 / 35
页数:10
相关论文
共 52 条
[31]   Effect of accelerated corneal crosslinking combined with transepithelial photorefractive keratectomy on dynamic corneal response parameters and biomechanically corrected intraocular pressure measured with a dynamic Scheimpflug analyzer in healthy myopic patients [J].
Lee, Hun ;
Roberts, Cynthia J. ;
Ambrosio, Renato, Jr. ;
Elsheikh, Ahmed ;
Kang, David Sung Yong ;
Kim, Tae-im .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2017, 43 (07) :937-945
[32]   Postoperative corneal swelling correlates strongly to corneal endothelial cell loss after phacoemulsification cataract surgery [J].
Lundberg, B ;
Jonsson, M ;
Behndig, A .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2005, 139 (06) :1035-1041
[33]   Endothelial Cell Loss and Central Corneal Thickness in Patients With and Without Diabetes After Manual Small Incision Cataract Surgery [J].
Mathew, Priya Thomas ;
David, Sarada ;
Thomas, Nihal .
CORNEA, 2011, 30 (04) :424-428
[34]   The organization of collagen in the corneal stroma [J].
Meek, KM ;
Boote, C .
EXPERIMENTAL EYE RESEARCH, 2004, 78 (03) :503-512
[35]   THE ORGANIZATION OF COLLAGEN FIBRILS IN THE HUMAN CORNEAL STROMA - A SYNCHROTRON X-RAY-DIFFRACTION STUDY [J].
MEEK, KM ;
BLAMIRES, T ;
ELLIOTT, GF ;
GYI, TJ ;
NAVE, C .
CURRENT EYE RESEARCH, 1987, 6 (07) :841-846
[36]   Intraocular pressure rise after small incision cataract surgery: a randomised intraindividual comparison of two dispersive viscoelastic agents [J].
Rainer, G ;
Menapace, R ;
Findl, O ;
Kiss, B ;
Petternel, V ;
Georgopoulos, M ;
Schneider, B .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2001, 85 (02) :139-142
[37]   Introduction of Two Novel Stiffness Parameters and Interpretation of Air Puff-Induced Biomechanical Deformation Parameters With a Dynamic Scheimpflug Analyzer [J].
Roberts, Cynthia J. ;
Mahmoud, Ashraf M. ;
Bons, Jeffrey P. ;
Hossain, Arif ;
Elsheikh, Ahmed ;
Vinciguerra, Riccardo ;
Vinciguerra, Paolo ;
Ambrosio, Renato, Jr. .
JOURNAL OF REFRACTIVE SURGERY, 2017, 33 (04) :266-+
[38]   Central corneal thickness changes after phacoemulsification cataract surgery [J].
Salvi, Sachin M. ;
Soong, Terrence K. ;
Kumar, Balakrishna V. ;
Hawksworth, Nicholas R. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (08) :1426-1428
[39]   Intraocular pressure after small incision cataract surgery: Temporal sclerocorneal versus clear corneal incision [J].
Schwenn, O ;
Dick, HB ;
Krummenauer, F ;
Krist, R ;
Pfeiffer, N .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2001, 27 (03) :421-425
[40]   Diurnal Variation of Ocular Hysteresis, Corneal Thickness, and Intraocular Pressure [J].
Shen, Meixiao ;
Wang, Jianhua ;
Qu, Jia ;
Xu, Suzhong ;
Wang, Xiaoxing ;
Fang, Haizhen ;
Lu, Fan .
OPTOMETRY AND VISION SCIENCE, 2008, 85 (12) :1185-1192